Determination of Lead and Cadmium in Water Samples by Adsorptive Stripping Voltammetry Using a Bismuth film/1-Nitroso-2-Napthol/Nafion Modified Glassy Carbon Electrode

被引:0
|
作者
Segura, Rodrigo A. [1 ]
Pizarro, Jaime A. [1 ]
Oyarzun, Maria P. [1 ]
Castillo, Alejandra D. [1 ]
Diaz, Karina J. [1 ]
Placencio, Alan B. [1 ]
机构
[1] Univ Santiago Chile USACH, Fac Quim & Biol, Dept Quim Mat, Casilla 40,Correo 33, Santiago 56227181172, Chile
来源
关键词
Adsorptive stripping voltammetry; bismuth film electrode; Nafion; cadmium and lead; MERCURY-FILM ELECTRODE; PYROGALLOL RED; TRACE-METALS; NICKEL; SPECIATION; COBALT; ACCUMULATION; SPECTROMETRY; CHEMISTRY; SENSORS;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The application and validation of a glassy carbon electrode modified with Nafion, 1-nitroso-2-naphthol and bismuth film (GC/NF-NN/BiFE) was studied using adsorptive stripping voltammetry (AdSV) for the determination of Pb2+ and Cd2+ in tap water. The parameters studied and optimized were pH, 1-nitroso-2-naphthol concentration (C-NN), Nafion concentration (C-NF), adsorption potential (E-acc) and adsorption time (t(acc)). Optimal conditions were pH 4.5 (acetate buffer solution 0.10 mol L-1); E-acc: -1.30 V; t(acc): 120 s; C-NN : 0.10% w/v, C-NF: 0.50 wt %. The detection and quantification limits were 0.08 and 0.29 mu g L-1 for Pb2+ and 0.07 and 0.24 mu g L-1 for Cd2+, with a linear range of 10 to 70 mu g L-1. Certified reference material (ICP Multi Element Standard) and synthetic samples were determined to validate the methodology, with satisfactory results. The stripping voltammetry method was tested on tap water.
引用
收藏
页码:1707 / 1719
页数:13
相关论文
共 50 条
  • [31] Adsorptive stripping voltammetry determination of methyldopa on the surface of a carboxylated multiwall carbon nanotubes modified glassy carbon electrode in biological and pharmaceutical samples
    Rezaei, Behzad
    Askarpour, Neda
    Ensafi, Ali A.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 109 : 253 - 258
  • [32] Differential pulse adsorptive stripping voltammetric determination of benzocaine and butacaine with Nafion modified glassy carbon electrode
    Reddy, Tukiakula Madhusudana
    Balaji, Kodigutta
    Reddy, Srinivasulu Jayarama Reddy
    CROATICA CHEMICA ACTA, 2006, 79 (02) : 253 - 259
  • [33] Differential Pulse Anodic Stripping Voltammetry Detection of Cadmium with Nafion-Graphene Modified Bismuth Film Electrode
    Wu, Saiwei
    Huang, Xiaolei
    Wu, Yuhua
    Luo, Liping
    Jin, Yuancheng
    Li, Qun
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10): : 8255 - 8262
  • [34] Determination of Lead(II) and Cadmium(II) in Selected Commercially Available Water-Based Paints of Ethiopia by Anodic Stripping Voltammetry Using a Bismuth-Modified Glassy Carbon Electrode
    Muluneh, Enidale Yazie
    Mekonnen, Menbere Leul
    Debebe, Siraye Esubalew
    CHEMISTRYSELECT, 2023, 8 (30):
  • [35] Determination of the fungicide picoxystrobin using anodic stripping voltammetry on a metal film modified glassy carbon electrode
    Dornellas, Rafael M.
    Franchini, Romulo A. A.
    Aucelio, Ricardo Q.
    ELECTROCHIMICA ACTA, 2013, 97 : 202 - 209
  • [36] Anodic stripping voltammetry of arsenic determination with edible mushroom-nafion-modified glassy carbon electrode
    Salinas, Arturo
    Trivino, Juan Jose
    Alvarez-Lueje, Alejandro
    Pizarro, Isabel
    Segura, Rodrigo
    Arancibia, Veronica
    TALANTA, 2024, 277
  • [37] Nafion®/2,2′-bipyridyl-modified bismuth film electrode for anodic stripping voltammetry
    Torma, Ferenc
    Kadar, Mihaly
    Toth, Klara
    Tatar, Eniko
    ANALYTICA CHIMICA ACTA, 2008, 619 (02) : 173 - 182
  • [38] Simultaneous Determination of Lead and Cadmium in the Presence of Morin by Adsorptive Stripping Voltammetry with a Nafion-Ionic Liquid-coated Mercury Film Electrode
    Nagles, Edgar
    Arancibia, Veronica
    Rios, Roxana
    Rojas, Carlos
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (06): : 5521 - 5533
  • [39] Highly Sensitive Levodopa Determination by Means of Adsorptive Stripping Voltammetry on Ruthenium Dioxide-Carbon Black-Nafion Modified Glassy Carbon Electrode
    Gorska, Anna
    Paczosa-Bator, Beata
    Piech, Robert
    SENSORS, 2021, 21 (01) : 1 - 12
  • [40] Determination of cadmium with a sequential injection lab-on-valve by anodic stripping voltammetry using a nafion coated bismuth film electrode
    Wang, Yang
    Liu, Zaiqing
    Yao, Guojun
    Zhu, Peihua
    Hu, Xiaoya
    Xu, Qin
    Yang, Chun
    TALANTA, 2010, 80 (05) : 1959 - 1963