Anodic stripping voltammetry of arsenic determination with edible mushroom-nafion-modified glassy carbon electrode

被引:1
|
作者
Salinas, Arturo [1 ]
Trivino, Juan Jose [1 ]
Alvarez-Lueje, Alejandro [1 ]
Pizarro, Isabel [2 ]
Segura, Rodrigo [3 ]
Arancibia, Veronica [1 ]
机构
[1] Univ Chile, Fac Ciencias Quim & Farmaceut, Santiago 8331150, Chile
[2] Univ Antofagasta, Fac Ciencias Basicas, Antofagasta 1270300, Chile
[3] Univ Santiago Chile, Fac Quim & Biol, Santiago 9170022, Chile
关键词
Mushroom modified electrode; Lentinula edodes; Agariscus bisporus; Arsenic determination; Adsorptive stripping voltammetry; Modified glassy carbon electrode; ELECTROCHEMICAL DETECTION; TRACE ARSENIC(III); NUTRITIONAL-VALUE; NANOPARTICLES; SPECIATION; CADMIUM; METALS; FUNGI; LEAD;
D O I
10.1016/j.talanta.2024.126391
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An edible Mushroom-Nafion modified glassy carbon electrode (M2N5-GCE) was prepared using a homogeneous mixture varying the concentrations of these, in addition to the origin of the mushroom (Shiitake, Lentinula edodes, M-1 and Abrantes, Agariscus bisporus, M-2) and applied to the As(III) determination by anodic stripping voltammetry. After choosing the optimal conditions in the preparation of the electrode, the second stage was to study the effects of various parameters such as supporting electrolyte, pH, accumulation potential, and time (E-acc, t(acc)). The optimum experimental conditions chosen were Britton Robinson buffer 0.01 mol L-1 pH:4.6; E-acc: -1.0 and t(acc): 60 s obtaining a signal of oxidation of As(0) to As(III) about 0.08 V. Peak current was proportional to arsenic concentration over the 19.6-117.6 mu g L-1 range, with a 3 sigma detection limit of 13.4 mu g L-1. The method was validated using As(III) spiked tap water from the laboratory with satisfactory results (RE:3.0 %). Finally, the method was applied to the determination of As(III) in water samples from the Loa River (Northern Chile) in the presence of As(V) in a concentration >20 times higher (RE: 2.3 %).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [2] Determination of mercury at a dithizone-modified glassy carbon electrode by anodic stripping voltammetry
    Huang, WS
    Zhang, SH
    ANALYTICAL SCIENCES, 2002, 18 (02) : 187 - 189
  • [3] Determination of Mercury at a Dithizone-Modified Glassy Carbon Electrode by Anodic Stripping Voltammetry
    Wensheng Huang
    Shenghui Zhang
    Analytical Sciences, 2002, 18 : 187 - 189
  • [4] Determination of trace xanthine by anodic stripping voltammetry with carbon nanotube modified glassy carbon electrode
    Zhao, G
    Zang, SQ
    Liu, KZ
    Lin, S
    Liang, J
    Guo, XY
    Zhang, ZJ
    ANALYTICAL LETTERS, 2002, 35 (14) : 2233 - 2244
  • [5] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [6] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83
  • [7] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Marcelina Łysoń
    Anna Górska
    Beata Paczosa-Bator
    Robert Piech
    Electrocatalysis, 2021, 12 : 641 - 649
  • [8] Nimesulide Determination on Carbon Black-Nafion Modified Glassy Carbon Electrode by Means of Adsorptive Stripping Voltammetry
    Lyson, Marcelina
    Gorska, Anna
    Paczosa-Bator, Beata
    Piech, Robert
    ELECTROCATALYSIS, 2021, 12 (06) : 641 - 649
  • [9] Pulse anodic stripping voltammetric determination of copper with an amoxicillin-nafion modified glassy carbon electrode
    Ramadan, A. A.
    Mandil, H.
    Saleh, M. A.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2008, 38 (12) : 1715 - 1720
  • [10] Determination of the fungicide picoxystrobin using anodic stripping voltammetry on a metal film modified glassy carbon electrode
    Dornellas, Rafael M.
    Franchini, Romulo A. A.
    Aucelio, Ricardo Q.
    ELECTROCHIMICA ACTA, 2013, 97 : 202 - 209