Toward Next-Generation Molecular Imaging with a Clinical Low-Field (0.064 T) Point-of-Care MRI Scanner

被引:2
|
作者
Iqbal, Nadiya [1 ]
Brittin, Drew O. [1 ]
Daluwathumullagamage, Praveen J. [1 ]
Alam, Md Shahabuddin [1 ]
Senanayake, Ishani M. [1 ]
Gafar, A. Tobi [1 ]
Siraj, Zahid [1 ]
Petrilla, Anthony [1 ]
Pugh, Margaret [1 ]
Tonazzi, Brockton [2 ]
Ragunathan, Sudarshan [3 ]
Poorman, Megan E. [3 ]
Sacolick, Laura [3 ]
Theis, Thomas [4 ]
Rosen, Matthew S. [5 ]
Chekmenev, Eduard Y. [6 ]
Goodson, Boyd M. [1 ]
机构
[1] Southern Illinois Univ, Sch Chem & Biomol Sci, Carbondale, IL 62901 USA
[2] Southern Illinois Univ, Sch Med, Carbondale, IL 62901 USA
[3] Hyperfine Inc, Guilford, CT 06437 USA
[4] North Carolina State Univ, Dept Chem, Raleigh, NC 27695 USA
[5] Harvard Univ, Sch Med, AA Martinos Ctr Biomed Imaging, Massachusetts Gen Hosp,Dept Radiol, Boston, MA 02129 USA
[6] Wayne State Univ, Karmanos Canc Inst KCI, Dept Chem, Integrat Biosci IBio, Detroit, MI 48202 USA
关键词
HETEROCYCLIC CARBENE COMPLEXES; PARA-HYDROGEN; REVERSIBLE EXCHANGE; IN-SITU; SABRE; PARAHYDROGEN; POLARIZATION; SPECTROSCOPY;
D O I
10.1021/acs.analchem.4c01299
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Low-field (LF) MRI promises soft-tissue imaging without the expensive, immobile magnets of clinical scanners but generally suffers from limited detection sensitivity and contrast. The sensitivity boost provided by hyperpolarization can thus be highly synergistic with LF MRI. Initial efforts to integrate a continuous-bubbling SABRE (signal amplification by reversible exchange) hyperpolarization setup with a portable, point-of-care 64 mT clinical MRI scanner are reported. Results from H-1 SABRE MRI of pyrazine and nicotinamide are compared with those of benchtop NMR spectroscopy. Comparison with MRI signals from samples with known H2O/D2O ratios allowed quantification of the SABRE enhancements of imaged samples with various substrate concentrations (down to 3 mM). Respective limits of detection and quantification of 3.3 and 10.1 mM were determined with pyrazine( 1)H polarization (P H) enhancements of similar to 1900 (P- H similar to 0.04%), supporting ongoing and envisioned efforts to realize SABRE-enabled MRI-based molecular imaging.
引用
收藏
页码:10348 / 10355
页数:8
相关论文
共 50 条
  • [41] Neurological manifestation of cerebrotendinous xanthomatosis-Clinical findings and cranial imaging in low-field MRI
    Klippel, Ekkehard
    Moshagen, Volker
    NERVENARZT, 2023, 94 (02): : 142 - 144
  • [42] Diagnostic abdominal MR imaging on a prototype low-field 0.55 T scanner operating at two different gradient strengths
    Hersh Chandarana
    Barun Bagga
    Chenchan Huang
    Bari Dane
    Robert Petrocelli
    Mary Bruno
    Mahesh Keerthivasan
    David Grodzki
    Kai Tobias Block
    David Stoffel
    Daniel K. Sodickson
    Abdominal Radiology, 2021, 46 : 5772 - 5780
  • [43] Diagnostic abdominal MR imaging on a prototype low-field 0.55 T scanner operating at two different gradient strengths
    Chandarana, Hersh
    Bagga, Barun
    Huang, Chenchan
    Dane, Bari
    Petrocelli, Robert
    Bruno, Mary
    Keerthivasan, Mahesh
    Grodzki, David
    Block, Kai Tobias
    Stoffel, David
    Sodickson, Daniel K.
    ABDOMINAL RADIOLOGY, 2021, 46 (12) : 5772 - 5780
  • [44] Portable bright-field, fluorescence, and cross-polarized microscope toward point-of-care imaging diagnostics
    Gordon, Paul
    Venancio, Vinicius Paula
    Mertens-Talcott, Susanne U.
    Cote, Gerard
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (09)
  • [45] Biosensing based on surface-enhanced Raman spectroscopy as an emerging/next-generation point-of-care approach for acute myocardial infarction diagnosis
    Low, Joyce Siew Yong
    Thevarajah, T. Malathi
    Chang, Siow Wee
    Goh, Boon Tong
    Khor, Sook Mei
    CRITICAL REVIEWS IN BIOTECHNOLOGY, 2020, 40 (08) : 1191 - 1209
  • [46] Challenges in Deploying Low-Field and Ultra-Low Field MRI in Research, Clinical Care, Population Screening, and Direct-to-Consumer Use
    Shen, Francis
    Wolf, Susan
    Garwood, Michael
    Han, Duke
    Illes, Judy
    Kimberly, W.
    Klein, Eran
    Rommelfanger, Karen
    Rosen, Matthew
    Sheth, Kevin
    Torres, Efrain
    Tuite, Paul
    Vaughan, John
    NEUROLOGY, 2022, 98 (18)
  • [47] A single-coil-based method for electromagnetic interference reduction in point-of-care low field MRI systems
    Parsa, Javad
    O'Reilly, Thomas
    Webb, Andrew
    JOURNAL OF MAGNETIC RESONANCE, 2023, 346
  • [48] REMISSIONPLUS, an Initiative to Integrate Modern Imaging into Rheumatologic Care - Review, Appraisal and Outlook: Evaluation of Low-Field MRI Data
    Sewerin, Philipp
    Klein, Sabine
    Brinks, Ralph
    Hoyer, Annika
    Schleich, Christoph
    Miese, Falk
    Blaschke, Sabine
    Edelmann, Edmund
    Gao, Ino K.
    Georgi, Joachim
    Keliner, Herbert
    Keysser, Gernot
    Lorenz, Hanns-Martin
    Mueller-Ladner, Ulf
    Pott, Hans-Georg
    Schulze-Koops, Hendrik
    Walther, Marisa
    Schmidt, Wolfgang A.
    Schneider, Matthias
    Ostendorf, Benedikt
    AKTUELLE RHEUMATOLOGIE, 2017, 42 (05) : 432 - 441
  • [49] Low-field benchtop NMR spectroscopy as a potential non-stationary tool for point-of-care urinary metabolite tracking in diabetic conditions
    Edgar, Mark
    Percival, Benita C.
    Gibson, Miles
    Jafari, Fereshteh
    Grootveld, Martin
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2021, 171
  • [50] More Space, Less Noise-New-generation Low-Field Magnetic Resonance Imaging Systems Can Improve Patient Comfort: A Prospective 0.55T-1.5T-Scanner Comparison
    Rusche, Thilo
    Vosshenrich, Jan
    Winkel, David J.
    Donners, Ricardo
    Segeroth, Martin
    Bach, Michael
    Merkle, Elmar M.
    Breit, Hanns-Christian
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (22)