Repeatability and Agreement of 4 Biometers Measuring Corneal Astigmatism in Eyes With Irregular Corneal Astigmatism Component

被引:0
|
作者
Wang, Lan [1 ]
Shao, Xu [1 ]
Fu, Jin-Ling [1 ]
Hu, Jing-Jing [1 ]
Zhou, Kai-Jing [1 ]
Li, Ran [1 ]
Yu, A-Yong [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Eye Hosp, Natl Clin Res Ctr Ocular Dis, Wenzhou, Peoples R China
[2] Wenzhou Med Univ, Eye Hosp, Natl Engn Res Ctr Ophthalmol & Optometry, Wenzhou, Peoples R China
[3] Wenzhou Med Univ, Eye Hosp, 270 Xueyuan West Rd, Wenzhou 325027, Zhejiang, Peoples R China
基金
国家重点研发计划;
关键词
SOURCE OPTICAL BIOMETRY; INTRAOCULAR-LENS; TOPOGRAPHY MEASUREMENTS; KERATOMETRY; POSTERIOR; COHERENCE; COMPARABILITY;
D O I
10.1016/j.ajo.2024.05.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the repeatability and agreement of corneal astigmatism measurements in eyes with irregular corneal astigmatism component (ICAC) using four devices: IOLMaster 700 biometer, Lenstar 900 biometer, iTrace, and Pentacam.<br /> DESIGN: Prospective cross-sectional reliability analysis.<br /> METHODS: Sixty-four eyes (52 patients) with ICAC were examined three times using the four devices. The eye with ICAC in this study is defined as the cornea has a certain degree of irregular astigmatism (asymmetric and/or skewed bowtie pattern of corneal topography according to corneal topography classification), accompanied with total corneal higher-order aberrations in the 4 mm zone of 0.3 mu m or greater. Corneal astigmatism was evaluated using three categories: anterior corneal astigmatism (ACA), posterior corneal astigmatism, and total corneal astigmatism (TCA). The repeatability was determined using the Delta Ast (arithmetic mean of vector differences among three repeated corneal astigmatism measurements). Bland-Altman plots and astigmatism vector analyses were employed to assess agreement.<br /> RESULTS: The IOLMaster 700 ( Delta Ast = 0.27 +/- 0.20 D) showcased higher repeatability in ACA measurements compared to iTrace ( Delta Ast = 0.37 +/- 0.38 D, P = .040) and Pentacam ( Delta Ast = 0.50 +/- 0.22 D, P < .001), and paralleled the performance of Lenstar 900 ( Delta Ast = 0.31 +/- 0.26 D, P = .338). The Pentacam ( Delta Ast = 0.09 +/- 0.07 D, P < .001) demonstrated superior repeatability in posterior corneal astigmatism, whereas the IOLMaster 700 ( Delta Ast = 0.33 +/- 0.23 D, P < .001) excelled in TCA. The IOLMaster 700 exhibited good agreement with either Lenstar 900 or iTrace, characterized by narrow 95% limits of agreement and clinically acceptable vector differences. Conversely, vector differences between Pentacam and the other three devices in ACA and TCA measurements were clinically significant, exceeding 0.50 D (all P < .05).<br /> CONCLUSIONS: In terms of repeatability of corneal astigmatism measurements in eyes with ICAC, the IOLMaster 700 and Lenstar 900 outperformed iTrace and Pentacam. While the IOLMaster 700 can be used interchangeably with either Lenstar 900 or iTrace, the Pentacam is not interchangeable with the other three devices.
引用
收藏
页码:200 / 212
页数:13
相关论文
共 50 条
  • [41] CORNEAL POWER AND ASTIGMATISM
    KRAGHA, IKOK
    ANNALS OF OPHTHALMOLOGY, 1986, 18 (01): : 35 - 37
  • [42] Corneal astigmatism and myopia
    Shum, PJT
    VISION RESEARCH, 1996, 36 : 1111 - 1111
  • [43] Measurement of corneal astigmatism
    ZHANG Kui 1
    2. The Sixth Research Institute
    ChineseScienceBulletin, 1998, (13) : 1124 - 1128
  • [44] Posterior corneal astigmatism
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12): : 1795 - 1795
  • [45] Measurement of corneal astigmatism
    Zhang, K
    Li, ZH
    Lu, WX
    Xing, R
    CHINESE SCIENCE BULLETIN, 1998, 43 (13): : 1124 - 1128
  • [46] Predictability of Refractive Outcome of a Small-Aperture Intraocular Lens in Eyes With Irregular Corneal Astigmatism
    Langer, Julian
    Shajari, Mehdi
    Kreutzer, Thomas
    Priglinger, Siegfried
    Mayer, Wolfgang J.
    Mackert, Marc J.
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (05) : 312 - +
  • [47] Astigmatism and corneal curvature
    Colin, J
    Cottereau, R
    JOURNAL OF REFRACTIVE SURGERY, 1996, 12 (01): : 7 - 7
  • [48] Contribution of Posterior Corneal Astigmatism to Total Corneal Astigmatism in a Sample of Egyptian Population
    Hosny, Mohamed
    Badawy, Alaa
    Khazbak, Lobna
    Anis, Mohamed
    Azzam, Sarah
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3325 - 3330
  • [49] Distribution of Posterior Corneal Astigmatism According to Axis Orientation of Anterior Corneal Astigmatism
    Miyake, Toshiyuki
    Shimizu, Kimiya
    Kamiya, Kazutaka
    PLOS ONE, 2015, 10 (01):
  • [50] Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes
    Tanabe, T
    Tomidokoro, A
    Samejima, T
    Miyata, K
    Sato, M
    Kaji, Y
    Oshika, T
    OPHTHALMOLOGY, 2004, 111 (04) : 752 - 757