Deep learning reconstructed T2-weighted Dixon imaging of the spine: Impact on acquisition time and image quality

被引:1
|
作者
Berkarda, Zeynep [1 ]
Wiedemann, Simon [1 ]
Wilpert, Caroline [1 ]
Strecker, Ralph [2 ]
Koerzdoerfer, Gregor [3 ]
Nickel, Dominik [3 ]
Bamberg, Fabian [1 ]
Benndorf, Matthias [1 ]
Mayrhofer, Thomas [4 ,5 ,6 ]
Russe, Maximilian Frederik [1 ]
Weiss, Jakob [1 ]
Diallo, Thierno D. [1 ]
机构
[1] Univ Freiburg, Univ Med Ctr Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Siemens Healthcare GmbH, EMEA Sci Partnerships, Erlangen, Germany
[3] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[4] Stralsund Univ Appl Sci, Sch Business Studies, Stralsund, Germany
[5] Massachusetts Gen Hosp, Cardiovasc Imaging Res Ctr, Dept Radiol, Boston, MA USA
[6] Harvard Med Sch, Boston, MA USA
关键词
Deep learning; Magnetic resonance imaging; Spine; Diagnostic imaging; MRI;
D O I
10.1016/j.ejrad.2024.111633
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:<bold> </bold>To assess the image quality and impact on acquisition time of a novel deep learning based T2 Dixon sequence (T2(DL)) of the spine. Methods:<bold> </bold>This prospective, single center study included n = 44 consecutive patients with a clinical indication for lumbar MRI at our university radiology department between September 2022 and March 2023. MRI examinations were performed on 1.5-T and 3-T scanners (MAGNETOM Aera and Vida; Siemens Healthineers, Erlangen, Germany) using dedicated spine coils. The MR study protocol consisted of our standard clinical protocol, including a T2 weighted standard Dixon sequence (T2(std)) and an additional T2(DL) acquisition. The latter used a conventional sampling pattern with a higher parallel acceleration factor. The individual contrasts acquired for Dixon water-fat separation were then reconstructed using a dedicated research application. After reconstruction of the contrast images from k-space data, a conventional water-fat separation was performed to provide derived water images. Two readers with 6 and 4 years of experience in interpreting MSK imaging, respectively, analyzed the images in a randomized fashion. Regarding overall image quality, banding artifacts, artifacts, sharpness, noise, and diagnostic confidence were analyzed using a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent image quality). Statistical analyses included the Wilcoxon signed-rank test and weighted Cohen's kappa statistics. Results: Forty-four patients (mean age 53 years (+/- 18), male sex: 39 %) were prospectively included. Thirty-one examinations were performed on 1.5 T and 13 examinations on 3 T scanners. A sequence was successfully acquired in all patients. The total acquisition time of T2(DL) was 93 s at 1.5-T and 86 s at 3-T, compared to 235 s, and 257 s, respectively for T2(std) (reduction of acquisition time: 60.4 % at 1.5-T, and 66.5 % at 3-T; p < 0.01). Overall image quality was rated equal for both sequences (median T2(DL): 5[3 -5], and median T2(std): 5 [2 -5]; p = 0.57). T2(DL) showed significantly reduced noise levels compared to T2(std) (5 [4 -5] versus 4 [3 -4]; p < 0.001). In addition, sharpness was rated to be significantly higher in T2(DL) (5 [4 -5] versus 4 [3 -5]; p < 0.001). Although T2(DL) displayed significantly more banding artifacts (5 [2 -5] versus 5 [4 -5]; p < 0.001), no significant impact on readers diagnostic confidence between sequences was noted (T2(std): 5 [2 -5], and T2(DL): 5 [3 -5]; p = 0.61). Substantial inter-reader and intrareader agreement was observed for T2(DL) overall image quality (kappa: 0.77, and kappa: 0.8, respectively). Conclusion: T2(DL) is feasible, yields an image quality comparable to the reference standard while substantially reducing the acquisition time.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] MRI T2-Weighted Imaging and Fat-Suppressed T2-Weighted Imaging Image Fusion Technology Improves Image Discriminablity for the Evaluation of Anal Fistulas
    Feng, Shi-Ting
    Huang, Mengqi
    Dong, Zhi
    Xu, Ling
    Li, Yin
    Jia, Yingmei
    Cai, Huasong
    Shen, Bingqi
    Li, Zi-Ping
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (03) : 429 - 437
  • [42] Accelerated T2-weighted MRI of the liver at 3 T using a single-shot technique with deep learning-based image reconstruction: impact on the image quality and lesion detection
    Luke A. Ginocchio
    Paul N. Smereka
    Angela Tong
    Vinay Prabhu
    Dominik Nickel
    Simon Arberet
    Hersh Chandarana
    Krishna P. Shanbhogue
    Abdominal Radiology, 2023, 48 : 282 - 290
  • [43] Accelerated T2-weighted MRI of the liver at 3 T using a single-shot technique with deep learning-based image reconstruction: impact on the image quality and lesion detection
    Ginocchio, Luke A.
    Smereka, Paul N.
    Tong, Angela
    Prabhu, Vinay
    Nickel, Dominik
    Arberet, Simon
    Chandarana, Hersh
    Shanbhogue, Krishna P.
    ABDOMINAL RADIOLOGY, 2023, 48 (01) : 282 - 290
  • [44] The applied research of simultaneous image acquisition of T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) in the assessment of patients with prostate cancer
    Liu, Yi
    Wang, Wei
    Qin, Xiu-Bo
    Wang, Hui-Hui
    Gao, Ge
    Zhang, Xiao-Dong
    Wang, Xiao-Ying
    ASIAN JOURNAL OF ANDROLOGY, 2019, 21 (02) : 177 - 182
  • [45] Acquisition time reduction of diffusion-weighted liver imaging using deep learning image reconstruction
    Afat, Saif
    Herrmann, Judith
    Almansour, Haidara
    Benkert, Thomas
    Weiland, Elisabeth
    Hoelldobler, Thomas
    Nikolaou, Konstantin
    Gassenmaier, Sebastian
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (04) : 178 - 184
  • [46] Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla
    E. K. Vos
    M. W. Lagemaat
    J. O. Barentsz
    J. J. Fütterer
    P. Zámecnik
    H. Roozen
    S. Orzada
    A. K. Bitz
    M. C. Maas
    T. W. J. Scheenen
    European Radiology, 2014, 24 : 1950 - 1958
  • [47] Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla
    Vos, E. K.
    Lagemaat, M. W.
    Barentsz, J. O.
    Fuetterer, J. J.
    Zamecnik, P.
    Roozen, H.
    Orzada, S.
    Bitz, A. K.
    Maas, M. C.
    Scheenen, T. W. J.
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1950 - 1958
  • [48] Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning–based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence
    Krishna Shanbhogue
    Angela Tong
    Paul Smereka
    Dominik Nickel
    Simon Arberet
    Rebecca Anthopolos
    Hersh Chandarana
    European Radiology, 2021, 31 : 8447 - 8457
  • [49] Comparison of T2-Weighted 3D-Space and T2-Weighted 2D-TSE Sequences in Lumbar Spine MR Imaging
    Qurat-ul-Ain
    Nadeem, Syed Farrukh
    Mirza, Tariq Mahmood
    Shafiq, Mazhar
    Batool, Zahida
    Khadijah-tul-Kubra
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2023, 29 (04): : 361 - 366
  • [50] Prognostic impact of T2-weighted CMR imaging for cardiac amyloidosis
    Ralf Wassmuth
    Hassan Abdel-Aty
    Steffen Bohl
    Jeanette Schulz-Menger
    European Radiology, 2011, 21 : 1643 - 1650