Deep learning reconstructed T2-weighted Dixon imaging of the spine: Impact on acquisition time and image quality

被引:1
|
作者
Berkarda, Zeynep [1 ]
Wiedemann, Simon [1 ]
Wilpert, Caroline [1 ]
Strecker, Ralph [2 ]
Koerzdoerfer, Gregor [3 ]
Nickel, Dominik [3 ]
Bamberg, Fabian [1 ]
Benndorf, Matthias [1 ]
Mayrhofer, Thomas [4 ,5 ,6 ]
Russe, Maximilian Frederik [1 ]
Weiss, Jakob [1 ]
Diallo, Thierno D. [1 ]
机构
[1] Univ Freiburg, Univ Med Ctr Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Siemens Healthcare GmbH, EMEA Sci Partnerships, Erlangen, Germany
[3] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[4] Stralsund Univ Appl Sci, Sch Business Studies, Stralsund, Germany
[5] Massachusetts Gen Hosp, Cardiovasc Imaging Res Ctr, Dept Radiol, Boston, MA USA
[6] Harvard Med Sch, Boston, MA USA
关键词
Deep learning; Magnetic resonance imaging; Spine; Diagnostic imaging; MRI;
D O I
10.1016/j.ejrad.2024.111633
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:<bold> </bold>To assess the image quality and impact on acquisition time of a novel deep learning based T2 Dixon sequence (T2(DL)) of the spine. Methods:<bold> </bold>This prospective, single center study included n = 44 consecutive patients with a clinical indication for lumbar MRI at our university radiology department between September 2022 and March 2023. MRI examinations were performed on 1.5-T and 3-T scanners (MAGNETOM Aera and Vida; Siemens Healthineers, Erlangen, Germany) using dedicated spine coils. The MR study protocol consisted of our standard clinical protocol, including a T2 weighted standard Dixon sequence (T2(std)) and an additional T2(DL) acquisition. The latter used a conventional sampling pattern with a higher parallel acceleration factor. The individual contrasts acquired for Dixon water-fat separation were then reconstructed using a dedicated research application. After reconstruction of the contrast images from k-space data, a conventional water-fat separation was performed to provide derived water images. Two readers with 6 and 4 years of experience in interpreting MSK imaging, respectively, analyzed the images in a randomized fashion. Regarding overall image quality, banding artifacts, artifacts, sharpness, noise, and diagnostic confidence were analyzed using a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent image quality). Statistical analyses included the Wilcoxon signed-rank test and weighted Cohen's kappa statistics. Results: Forty-four patients (mean age 53 years (+/- 18), male sex: 39 %) were prospectively included. Thirty-one examinations were performed on 1.5 T and 13 examinations on 3 T scanners. A sequence was successfully acquired in all patients. The total acquisition time of T2(DL) was 93 s at 1.5-T and 86 s at 3-T, compared to 235 s, and 257 s, respectively for T2(std) (reduction of acquisition time: 60.4 % at 1.5-T, and 66.5 % at 3-T; p < 0.01). Overall image quality was rated equal for both sequences (median T2(DL): 5[3 -5], and median T2(std): 5 [2 -5]; p = 0.57). T2(DL) showed significantly reduced noise levels compared to T2(std) (5 [4 -5] versus 4 [3 -4]; p < 0.001). In addition, sharpness was rated to be significantly higher in T2(DL) (5 [4 -5] versus 4 [3 -5]; p < 0.001). Although T2(DL) displayed significantly more banding artifacts (5 [2 -5] versus 5 [4 -5]; p < 0.001), no significant impact on readers diagnostic confidence between sequences was noted (T2(std): 5 [2 -5], and T2(DL): 5 [3 -5]; p = 0.61). Substantial inter-reader and intrareader agreement was observed for T2(DL) overall image quality (kappa: 0.77, and kappa: 0.8, respectively). Conclusion: T2(DL) is feasible, yields an image quality comparable to the reference standard while substantially reducing the acquisition time.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The Potential for Deep Learning Reconstruction to Improve the Quality of T2-weighted Prostate MRI
    Turkbey, Baris
    RADIOLOGY, 2023, 308 (03)
  • [32] Impact of uterine displacement on T2-weighted image quality in the female pelvic MRI
    Ishikawa, Hironobu
    Monma, Masahiko
    Ishimori, Yoshiyuki
    Saotome, Kousaku
    Ishii, Shiro
    Sekino, Hirofumi
    Yamakuni, Ryo
    Kakamu, Takeyasu
    Oura, Daisuke
    Takahashi, Yuma
    Seino, Shinya
    Yusa, Masanori
    Ito, Hiroshi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (01) : 127 - 135
  • [33] T2-weighted Dixon MRI of the spine: A feasibility study of quantitative vertebral bone marrow analysis
    Donners, Ricardo
    Hirschmann, Anna
    Gutzeit, Andreas
    Harder, Dorothee
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (7-8) : 431 - 438
  • [34] Reduction in Acquisition Time and Improvement in Image Quality in T2-Weighted MR Imaging of Musculoskeletal Tumors of the Extremities Using a Novel Deep Learning-Based Reconstruction Technique in a Turbo Spin Echo (TSE) Sequence
    Wessling, Daniel
    Herrmann, Judith
    Afat, Saif
    Nickel, Dominik
    Othman, Ahmed E.
    Almansour, Haidara
    Gassenmaier, Sebastian
    TOMOGRAPHY, 2022, 8 (04) : 1759 - 1769
  • [35] Fast T2-Weighted Imaging With Deep Learning-Based Reconstruction: Evaluation of Image Quality and Diagnostic Performance in Patients Undergoing Radical Prostatectomy
    Park, Jae Chun
    Park, Kye Jin
    Park, Mi Yeon
    Kim, Mi-Hyun
    Kim, Jeong Kon
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (06) : 1735 - 1744
  • [36] The Image Evaluation of Iterative Motion Correction Reconstruction Algorithm PROPELLER T2-Weighted Imaging Compared with MultiVane T2-Weighted Imaging
    Lee, Suk-Jun
    Yu, Seung-Man
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 71 (04) : 238 - 243
  • [37] The image evaluation of iterative motion correction reconstruction algorithm PROPELLER T2-weighted imaging compared with MultiVane T2-weighted imaging
    Suk-Jun Lee
    Seung-Man Yu
    Journal of the Korean Physical Society, 2017, 71 : 238 - 243
  • [38] T2-weighted spine Imaging with a fast three-point Dixon technique: Comparison with chemical shift selective fat suppression
    Ma, JF
    Singh, SK
    Kumar, AJ
    Leeds, NE
    Zhan, JP
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) : 1025 - 1029
  • [39] Prostate Cancer: Comparison of 3D T2-Weighted With Conventional 2D T2-Weighted Imaging for Image Quality and Tumor Detection
    Rosenkrantz, Andrew B.
    Neil, Jeffry
    Kong, Xiangtian
    Melamed, Jonathan
    Babb, James S.
    Taneja, Samir S.
    Taouli, Bachir
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) : 446 - 452
  • [40] Clinical Utility of a Novel Ultrafast T2-Weighted Sequence for Spine Imaging
    Keerthivasan, M. B.
    Winegar, B.
    Becker, J. L.
    Bilgin, A.
    Altbach, M. I.
    Saranathan, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (08) : 1568 - 1575