Deep learning reconstructed T2-weighted Dixon imaging of the spine: Impact on acquisition time and image quality

被引:1
|
作者
Berkarda, Zeynep [1 ]
Wiedemann, Simon [1 ]
Wilpert, Caroline [1 ]
Strecker, Ralph [2 ]
Koerzdoerfer, Gregor [3 ]
Nickel, Dominik [3 ]
Bamberg, Fabian [1 ]
Benndorf, Matthias [1 ]
Mayrhofer, Thomas [4 ,5 ,6 ]
Russe, Maximilian Frederik [1 ]
Weiss, Jakob [1 ]
Diallo, Thierno D. [1 ]
机构
[1] Univ Freiburg, Univ Med Ctr Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Siemens Healthcare GmbH, EMEA Sci Partnerships, Erlangen, Germany
[3] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[4] Stralsund Univ Appl Sci, Sch Business Studies, Stralsund, Germany
[5] Massachusetts Gen Hosp, Cardiovasc Imaging Res Ctr, Dept Radiol, Boston, MA USA
[6] Harvard Med Sch, Boston, MA USA
关键词
Deep learning; Magnetic resonance imaging; Spine; Diagnostic imaging; MRI;
D O I
10.1016/j.ejrad.2024.111633
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:<bold> </bold>To assess the image quality and impact on acquisition time of a novel deep learning based T2 Dixon sequence (T2(DL)) of the spine. Methods:<bold> </bold>This prospective, single center study included n = 44 consecutive patients with a clinical indication for lumbar MRI at our university radiology department between September 2022 and March 2023. MRI examinations were performed on 1.5-T and 3-T scanners (MAGNETOM Aera and Vida; Siemens Healthineers, Erlangen, Germany) using dedicated spine coils. The MR study protocol consisted of our standard clinical protocol, including a T2 weighted standard Dixon sequence (T2(std)) and an additional T2(DL) acquisition. The latter used a conventional sampling pattern with a higher parallel acceleration factor. The individual contrasts acquired for Dixon water-fat separation were then reconstructed using a dedicated research application. After reconstruction of the contrast images from k-space data, a conventional water-fat separation was performed to provide derived water images. Two readers with 6 and 4 years of experience in interpreting MSK imaging, respectively, analyzed the images in a randomized fashion. Regarding overall image quality, banding artifacts, artifacts, sharpness, noise, and diagnostic confidence were analyzed using a 5-point Likert scale (from 1 = non-diagnostic to 5 = excellent image quality). Statistical analyses included the Wilcoxon signed-rank test and weighted Cohen's kappa statistics. Results: Forty-four patients (mean age 53 years (+/- 18), male sex: 39 %) were prospectively included. Thirty-one examinations were performed on 1.5 T and 13 examinations on 3 T scanners. A sequence was successfully acquired in all patients. The total acquisition time of T2(DL) was 93 s at 1.5-T and 86 s at 3-T, compared to 235 s, and 257 s, respectively for T2(std) (reduction of acquisition time: 60.4 % at 1.5-T, and 66.5 % at 3-T; p < 0.01). Overall image quality was rated equal for both sequences (median T2(DL): 5[3 -5], and median T2(std): 5 [2 -5]; p = 0.57). T2(DL) showed significantly reduced noise levels compared to T2(std) (5 [4 -5] versus 4 [3 -4]; p < 0.001). In addition, sharpness was rated to be significantly higher in T2(DL) (5 [4 -5] versus 4 [3 -5]; p < 0.001). Although T2(DL) displayed significantly more banding artifacts (5 [2 -5] versus 5 [4 -5]; p < 0.001), no significant impact on readers diagnostic confidence between sequences was noted (T2(std): 5 [2 -5], and T2(DL): 5 [3 -5]; p = 0.61). Substantial inter-reader and intrareader agreement was observed for T2(DL) overall image quality (kappa: 0.77, and kappa: 0.8, respectively). Conclusion: T2(DL) is feasible, yields an image quality comparable to the reference standard while substantially reducing the acquisition time.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Image quality and lesion detectability of deep learning-accelerated T2-weighted Dixon imaging of the cervical spine
    Seo, Geojeong
    Lee, Sun Joo
    Park, Dae Hyun
    Paeng, Sung Hwa
    Koerzdoerfer, Gregor
    Nickel, Marcel Dominik
    Sung, Jaekon
    SKELETAL RADIOLOGY, 2023, 52 (12) : 2451 - 2459
  • [2] Image quality and lesion detectability of deep learning-accelerated T2-weighted Dixon imaging of the cervical spine
    Geojeong Seo
    Sun Joo Lee
    Dae Hyun Park
    Sung Hwa Paeng
    Gregor Koerzdoerfer
    Marcel Dominik Nickel
    Jaekon Sung
    Skeletal Radiology, 2023, 52 : 2451 - 2459
  • [3] Deep learning can reduce acquisition time of T2-weighted image in brain imaging
    El-Saeed Abou-ELMagd, Eman Hassan
    Elmogy, Sabry Alameldin
    Abdelzaher, Dina Gamal
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2025, 56 (01):
  • [4] Deep learning-accelerated T2-weighted imaging of the prostate: Reduction of acquisition time and improvement of image quality
    Gassenmaier, Sebastian
    Afat, Saif
    Nickel, Dominik
    Mostapha, Mahmoud
    Herrmann, Judith
    Othman, Ahmed E.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 137
  • [5] Comparative analysis of image quality and interchangeability between standard and deep learning-reconstructed T2-weighted spine MRI
    Lee, Seungeun
    Jung, Joon-Yong
    Chung, Heeyoung
    Lee, Hyun-Soo
    Nickel, Dominik
    Lee, Jooyeon
    Lee, So-Yeon
    MAGNETIC RESONANCE IMAGING, 2024, 109 : 211 - 220
  • [6] Faster Acquisition and Improved Image Quality of T2-Weighted Dixon Breast MRI at 3T Using Deep Learning: A Prospective Study
    Wilpert, Caroline
    Schneider, Hannah
    Rau, Alexander
    Russe, Maximilian Frederic
    Oerther, Benedict
    Strecker, Ralph
    Nickel, Marcel Dominic
    Weiland, Elisabeth
    Haeger, Alexa
    Benndorf, Matthias
    Mayrhofer, Thomas
    Weiss, Jakob
    Bamberg, Fabian
    Windfuhr-Blum, Marisa
    Neubauer, Jakob
    KOREAN JOURNAL OF RADIOLOGY, 2025, 26 (01) : 29 - 42
  • [7] Deep learning-accelerated T2-weighted imaging versus conventional T2-weighted imaging in the female pelvic cavity: image quality and diagnostic performance
    Kim, Hokun
    Choi, Moon Hyung
    Lee, Young Joon
    Han, Dongyeob
    Mostapha, Mahmoud
    Nickel, Dominik
    ACTA RADIOLOGICA, 2024, 65 (05) : 499 - 505
  • [8] Deep learning denoising reconstruction enables faster T2-weighted FLAIR sequence acquisition with satisfactory image quality
    Brain, Matthew E.
    Amukotuwa, Shalini
    Bammer, Roland
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2024, 68 (04) : 377 - 384
  • [9] Deep learning-accelerated T2-weighted imaging of the prostate: Impact of further acceleration with lower spatial resolution on image quality
    Kim, Eu Hyun
    Choi, Moon Hyung
    Lee, Young Joon
    Han, Dongyeob
    Mostapha, Mahmoud
    Nickel, Dominik
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 145
  • [10] Accelerated T2-Weighted TSE Imaging of the Prostate Using Deep Learning Image Reconstruction: A Prospective Comparison with Standard T2-Weighted TSE Imaging
    Gassenmaier, Sebastian
    Afat, Saif
    Nickel, Marcel Dominik
    Mostapha, Mahmoud
    Herrmann, Judith
    Almansour, Haidara
    Nikolaou, Konstantin
    Othman, Ahmed E.
    CANCERS, 2021, 13 (14)