Electrothermal damage numerical analysis for overhead ground wire at terminal of armor rods under short-circuit current

被引:0
|
作者
Li, Hongfa [1 ,2 ]
Cheng, Lang [3 ]
Huang, Beisi [1 ]
Cheng, Shaobing [4 ]
Lin, Jiayao [1 ]
Nie, Wenxiang [2 ]
Guo, Deming [1 ]
Liu, Gang [1 ]
机构
[1] South China Univ Technol, Sch Elect Power Engn, Guangzhou 510640, Peoples R China
[2] Guangdong Power Grid Co Ltd, Zhongshan Power Supply Bur, Zhongshan 528400, Peoples R China
[3] South China Univ Technol, Shien Ming Wu Sch Intelligent Engn, Guangzhou 511442, Peoples R China
[4] Guangdong Power Grid Co Ltd, Training & Assessment Ctr, Guangzhou 510000, Peoples R China
基金
中国国家自然科学基金;
关键词
Overhead ground wire; Conductive bridge model; Armor rods; Electromagnetic-thermal-structural coupling; CONTACTS; POWER;
D O I
10.1007/s00202-024-02767-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Overhead ground wires (OGW) are installed to protect conductors from lightning strikes. However, the elevated temperature at the terminal of armor rods (TAR) under the influence of short-circuit currents can cause accidents resulting in breakage of OGW. To simulate the electrothermal damage process of TAR, an improved conductive bridge model considering the coupled relationship between electromagnetic force (FE) and the contact area is established. Then, a finite element model is built based on the improved model to assess TAR damage severity by analyzing the equivalent plastic strain considering thermal behavior. In addition, the calculation results of different conductive bridge models are compared. The findings indicate that the maximum temperature at the TAR contact surface can exceed the steel melting point, leading to significant thermal stress and elevated equivalent plastic strain. The improved model considering the coupling between FE and contact area shows better accuracy in predicting the electrothermal damage, validated by temperature rise experiments. The proposed modeling method has potential applications in related research areas.
引用
收藏
页码:4313 / 4323
页数:11
相关论文
共 34 条
  • [21] Calculation of short-circuit current distribution between OPGW and ordinary ground wire under single-phase earth fault occurred in transmission system simultaneously configuring both kinds of ground wires
    Xu, Gaoxiong
    Zhao, Daping
    Qi, Liyan
    Ding, Huixia
    Jia, Meijian
    Zhang, Yu
    Dianwang Jishu/Power System Technology, 2011, 35 (01): : 229 - 232
  • [22] Analysis of the Hybrid-MMC-HVDC Short-Circuit Current under MMC AC System Symmetrical Fault
    Sun, Shengya
    Wang, Shanshan
    Sun, Yuanyuan
    Yu, Xiao
    Yin, Rui
    Hu, Hong
    Ding, Haoyin
    Li, Jianhua
    Cao, Lu
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 41 - 45
  • [23] Numerical analysis of grounding impedance for grounding grids with multi-points short circuit current into the ground
    Lu, Zhiwei
    Chang, Shusheng
    Lan, Shuli
    Wen, Xishan
    Gaodianya Jishu/High Voltage Engineering, 2004, 30 (10):
  • [24] Analysis of current pulse during short-circuit phase in CMT version of GMAW process under a view of additive manufacturing
    Galeazzi, Daniel
    Goncalves e Silva, Regis Henrique
    Pigozzo, Ivan Olszanski
    da Rosa, Alisson Fernandes
    Pereira, Alex Sandro
    Marques, Cleber
    WELDING IN THE WORLD, 2022, 66 (07) : 1369 - 1380
  • [25] Analysis of Short-circuit Current Characteristics of Wind Farm with MMC-HVDC Transmission System under Symmetrical Fault
    Zhang, Mengyao
    Xu, Ling
    Huang, Ruanming
    Zhang, Tian
    Lin, Yongchao
    Yao, Jun
    2024 7TH ASIA CONFERENCE ON ENERGY AND ELECTRICAL ENGINEERING, ACEEE 2024, 2024, : 161 - 165
  • [26] Analysis of current pulse during short-circuit phase in CMT version of GMAW process under a view of additive manufacturing
    Daniel Galeazzi
    Régis Henrique Gonçalves e Silva
    Ivan Olszanski Pigozzo
    Alisson Fernandes da Rosa
    Alex Sandro Pereira
    Cleber Marques
    Welding in the World, 2022, 66 : 1369 - 1380
  • [27] Statistical analysis of the double line-to-ground short-circuit current in MV urban network for the power cable metallic screen rating
    Korab, Roman
    Siwy, Edward
    2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 973 - 978
  • [28] Comparative Analysis of Small Scale Short-circuit Failure of IGBT Bridge Leg Under Over-current Protection Mechanism
    Dou Z.
    Wang Y.
    Wu J.
    Guo L.
    Li Y.
    Wu Z.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (24): : 7325 - 7335
  • [29] Short-Circuit Current Calculation and Harmonic Characteristic Analysis for a Doubly-Fed Induction Generator Wind Turbine under Converter Control
    Li, Jing
    Zheng, Tao
    Wang, Zengping
    ENERGIES, 2018, 11 (09)
  • [30] Simulation and analysis of induced voltage and current on overhead ground wire of Huainan~Wannan~Zhebei~Huxi 1000 kV UHV AC double-circuit transmission line
    Li, Bao-Ju
    Zhou, Hao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (10): : 86 - 89