Thermal behaviour of a transformer mineral oil-tank surface under incipient turn-to-turn short-circuit fault

被引:0
|
作者
Chen, Si [1 ]
Luo, Yingting [2 ]
Sheng, Gehao [1 ]
Jiang, Junfei [2 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[2] Guangdong Power Grid Co Ltd, Elect Power Res Inst, Guangzhou, Peoples R China
关键词
temperature distribution; temperature measurement; thermal analysis; transformer windings; AGING ASSESSMENT MODEL; FUNDAMENTAL APPROACH;
D O I
10.1049/smt2.12200
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A slight turn-to-turn short-circuit fault in the incipient stage does not trigger fuse protection, and the regular transmission and transformation functions of the transformer within the power grid are not affected very much by the incipient turn-to-turn short-circuit fault. Therefore, the incipient turn-to-turn short-circuit faults are often undetected, resulting in massive accidents. Incipient turn-to-turn short-circuit faults lead to localized overheating in the transformer, which changes the transformer's oil-tank surface temperature (OTST). A thermal simulation model (TSM) is presented. Based on the TSM, OTST data with different load rates and fault parameters are collected. The steady-state and transient characteristics of OTST are analysed by extracting the OTST feature vector and the temperature difference of specific regions. The results show that the growth of the heat production value of faulty coils causes a rise in the OTST; higher faulty coils' locations lead to wider OTST differences; the temperature difference's area S can follow the incipient short-circuit fault in the first 20 min after it occurs, which is faster than the top oil temperature. This study gives insight into the thermal behaviour of OTST, assisting in fault detection and location at the incipient fault stage. This paper proposed a thermal simulation model of the oil-immersed transformer and analysed the oil-tank surface's steady-state and transient thermal behaviours under incipient turn-to-turn short-circuit faults. The oil-tank surface temperature (OTST) feature vector b is proposed to show the overall thermal behaviour of the oil-tank surface, and the temperature difference of the specific regions TF(S, hF) is analysed to show the local thermal behaviour. The proposed dynamic analysis and steady-state methods of analysing the thermal behaviour of OTST can help guide online monitoring and fault detection of transformers. image
引用
收藏
页码:310 / 323
页数:14
相关论文
共 50 条
  • [31] Three-phase current injection method for mitigating turn-to-turn short-circuit fault in concentrated-winding permanent magnet aircraft starter generator
    Jiang, Yunyi
    Zhang, Zhuoran
    Jiang, Wenying
    Geng, Weiwei
    Huang, Jian
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (04) : 566 - 574
  • [32] Detection of an Incipient Rotor Winding Inter-Turn Short Circuit Fault
    Sabir, Hamza
    Ouassaid, Mohammed
    Ngote, Nabil
    PROCEEDINGS OF THE 2021 XXIII IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC 2021), 2021,
  • [33] Detection of Incipient Inter-Turn Short-Circuit Faults by Artificial Intelligence Classifiers
    Orgut, Osman
    Sahin, Ilker
    Gunes, Ece Olcay
    2022 24TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'22 ECCE EUROPE), 2022,
  • [34] Analysis and detection of turn-to-turn short circuit fault in a permanent magnet Vernier generator based on modified winding function
    Arianborna, MohammadHossein
    Faiz, Jawad
    Ghods, Mehrage
    Bazrafshan, Mohammad
    IET ELECTRIC POWER APPLICATIONS, 2021, 15 (12) : 1630 - 1647
  • [35] Turn-to-Turn Short Circuit of Motor Stator Fault Diagnosis Using Dropout Rate Improved Deep Sparse AutoEncoder
    Wang, Botao
    Ma, Baohui
    Xu, Kexing
    Zheng, Tingting
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 220 - 225
  • [36] Turn-to-Turn Short Circuit of Motor Stator Fault Diagnosis in Continuous State Based on Deep Auto-Encoder
    Wang, Botao
    Xu, Kexing
    Zheng, Tingting
    Shen, Chuanwen
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 876 - 880
  • [37] Turn-to-turn short circuit of motor stator fault diagnosis in continuous state based on deep auto-encoder
    Wang, Botao
    Shen, Chuanwen
    Xu, Kexing
    Zheng, Tingting
    IET ELECTRIC POWER APPLICATIONS, 2019, 13 (10) : 1598 - 1606
  • [38] Simulation Analysis and Scaling Test of Transformer Turn to Turn Short-Circuit Transient Characteristics Based on Field-Circuit Cooperation
    Chen, Zhiwei
    Yang, Ruibo
    Wang, Junxian
    Xiang, Nianwen
    Liu, Xin
    IEEJ Transactions on Electrical and Electronic Engineering,
  • [39] Simulation Analysis and Scaling Test of Transformer Turn to Turn Short-Circuit Transient Characteristics Based on Field-Circuit Cooperation
    Chen, Zhiwei
    Yang, Ruibo
    Wang, Junxian
    Xiang, Nianwen
    Liu, Xin
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2025,
  • [40] Fault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
    Zhang, Jiayuan
    Zhan, Wei
    Ehsani, Mehrdad
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (04) : 2267 - 2275