Clinical applications of the T-Scan quantitative digital occlusal analysis technology: a systematic review

被引:3
|
作者
Chowdhary, Ramesh [1 ]
Sonnahalli, Nithin Kumar [1 ]
机构
[1] Branemark Osseointegrat Ctr India, Bengaluru 560040, India
关键词
T-Scan; digital occlusal analysis; PAIN-DYSFUNCTION SYNDROME; ANTERIOR GUIDANCE DEVELOPMENT; DISCLUSION TIME; COMPUTERIZED ANALYSIS; TEMPOROMANDIBULAR DISORDERS; MUSCLE-ACTIVITY; ORTHODONTIC TREATMENT; FORCE PARAMETERS; CONTACTS; ASSOCIATION;
D O I
10.3290/j.ijcd.b3945153
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of the problem: Occlusion is associated with all disciplines of dentistry and plays a major role in the longevity of both implant- and tooth -borne restorations. Achieving occlusal harmony ensures balance is established between the dental and myofascial structures, which can be measurably established to high numerical tolerances with the T -Scan digital occlusal analysis system. Purpose: To describe and evaluate the known and proven applications of T -Scan digital occlusal analysis in various dental practice disciplines through a systematic review of the literature. Materials and methods: An electronic, English -language PubMed/MEDLINE and Cochrane Central Registry of Controlled Trials database search using the keywords "T -Scan," "TMD," "Occlusion," "Implant Protected Occlusion," and "Orthodontics" was conducted without any date restrictions. The related journal findings were hand searched to determine studies that met the eligibility criteria for inclusion in the present systematic review. Results: The PubMed/MEDLINE search identified 423 articles. After removing duplicates, the titles and abstracts of the remaining 421 studies were screened. 274 ineligible articles were excluded, leaving 147 articles. Of those, 33 articles were not in English, 27 full -text articles were not available, 4 were comments and letters to editors, 1 was a review, and 2 described techniques. A total of 86 articles met the eligibility criteria for inclusion. Conclusion: Much scientific evidence supports the use of T -Scan, as it measures relative occlusal contact forces and the time sequence durations of occlusal contacts objectively, accurately, and repeatedly for improved treatment outcomes. The system's hardware, sensor, and software evolution from T -Scan Ito today's T -Scan 10 Novus system has overcome early sensor and system drawbacks to improve the clinical performance of T -Scan in many disciplines of dental medicine. (Int J Comput Dent 2024;27(1):49-86; doi:10.3290/j. ijcd.b3945153)
引用
收藏
页码:49 / 86
页数:38
相关论文
共 50 条
  • [21] Aspects of Occlusal Recordings Performed with the T-Scan System and with the Medit Intraoral Scanner
    Popa, Angelica Diana
    Vladutu, Diana Elena
    Turcu, Adina Andreea
    Tartea, Daniel Adrian
    Ionescu, Mihaela
    Paunescu, Catalin
    Stan, Razvan Sabin
    Mercut, Veronica
    DIAGNOSTICS, 2024, 14 (13)
  • [22] =T-Scan Guided Occlusal Equilibration as an Effective Treatment in the Management of Symptomatic Temporomandibular Disorders: An Open Clinical Trial
    Ignatius, Ancy, V
    Garlapati, Komali
    Chaitanya, Nallan C. S. K.
    Saba, Asra
    Kandi, Pallavi
    Reddy, Chelluri Shreya
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (01) : 53 - 59
  • [23] A study on the mandibular arc of closure reproducibility using the T-Scan III computerized occlusal analysis system
    Balos, Monica Dora
    Soaita, Claudia
    Cerghizan, Diana
    Popsor, Sorin
    8TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2014, 2015, 19 : 916 - 920
  • [24] Use of T-Scan III in analyzing occlusal changes in molar fixed denture placement
    Chan, Hei
    Alimujiang, Adili
    Fong, Sin Iok
    Wu, Ming-Le
    Liang, Ran
    Lai, Peng-Yu
    Wei, Hui-Wen
    Shen, Shan
    BMC ORAL HEALTH, 2024, 24 (01)
  • [25] Use of T-Scan III in analyzing occlusal changes in molar fixed denture placement
    Hei Chan
    Adili Alimujiang
    Sin Iok Fong
    Ming-Le Wu
    Ran Liang
    Peng-Yu Lai
    Hui-Wen Wei
    Shan Shen
    BMC Oral Health, 24
  • [26] Application in the analysis of the occlusal force of free-end missing tooth implant restoration with T-SCAN III
    Wu, Ming-Le
    Lai, Peng-Yu
    Cheong, Fan
    Zhou, Wen-Cheng
    Xu, Sang-Hui
    Li, Hui
    Shen, Shan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [27] Reference values and reliability of occlusal force distribution and occlusal time measured by the T-Scan system in adults with healthy dentition
    Rubio-Ferrer, Gemma
    Rovira-Lastra, Bernat
    Khoury-Ribas, Laura
    Flores-Orozco, Elan Ignacio
    Ayuso-Montero, Raul
    Martinez-Gomis, Jordi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (06): : 558 - 564
  • [28] Evaluation of the accuracy of T-scan system and Cerec Omnicam system used in occlusal contact assessment
    Cao, Rongkai
    Xu, Hui
    Lin, Jing
    Liu, Weicai
    HELIYON, 2023, 9 (02)
  • [29] Effect of mandibular complete dentures relining on occlusal force distribution using T-scan system
    Eman M. Ibraheem
    Hisham S. ElGabry
    Bulletin of the National Research Centre, 45 (1)
  • [30] Systematic review of digital twin technology and applications
    Jun-Feng Yao
    Yong Yang
    Xue-Cheng Wang
    Xiao-Peng Zhang
    Visual Computing for Industry, Biomedicine, and Art, 6