Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy

被引:1
|
作者
Consorti, Giuseppe [1 ]
Betti, Enrico [1 ]
Catarzi, Lisa [1 ,2 ]
机构
[1] Azienda Osped Univ Ospedali Riuniti Ancona, Dept Maxillofacial Surg, Umberto, Italy
[2] Univ Siena, Dept Maxillofacial Surg, Siena, Italy
关键词
Computer -assisted surgery; Orbital fracture; Blow-out fracture; Customized orbital implant; Preformed titanium mesh; Intraoperative navigation; FLOOR;
D O I
10.1016/j.jcms.2024.02.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups ( p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups ( p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 50 条
  • [31] Orbital Bone Fracture Repair Evaluation Through 3-Dimensional Computational Reconstruction and Orbital Volumetric Assessment
    Passaglia, Igor R. G.
    Bastos, Endrigo O.
    Moura, Lucas B.
    Secanho, Murilo S.
    Alonso, Nivaldo
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2024, 12 (12)
  • [32] Use of 3D orbital reconstruction in the assessment of orbital sexual dimorphism and its pathological consequences
    Graillon, N.
    Boulze, C.
    Adalian, P.
    Loundou, A.
    Guyot, L.
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2017, 118 (01): : 29 - 34
  • [33] 3D Orbital Reconstruction in a Patient with Microphthalmos and a Large Orbital Cyst-A Case Report
    Mourits, D. L.
    Wolff, J.
    Forouzanfar, T.
    Ridwan-Pramana, A.
    Moll, A. C.
    de Graaf, P.
    Remmers, J. S.
    Kraal-Biezen, E.
    Hartong, D. T.
    OPHTHALMIC GENETICS, 2016, 37 (02) : 233 - 237
  • [34] Topographic CT data analysis and classification of the human orbital floor, virtual templates for computer aided reconstruction and the fabrication of preformed 3D implants for orbital floor fractures
    Metzger, M. C.
    Teschner, M.
    Schulze, D.
    Hohlweg-Majert, B.
    Gellrich, N. -C.
    Schmelzeisen, R.
    Schoen, R.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S229 - S231
  • [35] Case Report: Facial fracture sequelae: the importance of using a specific customized implant (PSI) for orbital reconstruction
    Pulino, Bianca
    Fonseca, Leonardo Alckmin Hotz
    Vieira, Eduardo Hochuli
    Piteri Filho, Jose Roberto
    de Macedo, Thiago Felippe Oliveira
    D'Amado, Marcelo Pigatto
    Pereira, Rodrigo
    Santos, Igor Alexandre Damasceno
    Ilesan, Robert
    Moreira, Henrique Cabrini
    Viana, Drielli
    Guerra, Raphael Capelli
    FRONTIERS IN SURGERY, 2024, 11
  • [36] "6 Anatomical Landmarks" Technique for Satisfactory Free-Hand Orbital Reconstruction With Standard Preformed Titanium Mesh
    Canzi, Gabriele
    Corradi, Federica
    Novelli, Giorgio
    Bozzetti, Alberto
    Sozzi, Davide
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2022, 15 (01) : 51 - 57
  • [37] Titanium Mesh Reconstruction of Orbital Roof Fracture with Traumatic Encephalocele: A Case Report and Review of Literature
    Mokal, Nitin J.
    Desai, Mahinoor F.
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2012, 5 (01) : 11 - 17
  • [38] Comparison of Nasoseptal Cartilage Graft Versus Titanium Mesh in Reconstruction of Pure Orbital Blowout Fractures
    Mangan, Mehmet Serhat
    Goker, Ayse Enise
    Yurttaser Ocak, Serap
    Uyar, Yavuz
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (04) : 1511 - 1514
  • [39] Comparison of patient specific implant reconstruction vs conventional titanium mesh reconstruction of orbital fractures using a novel method
    Krasovsky, Andrei
    Hija, Ahmad
    Zeineh, Nidal
    Capucha, Tal
    Haze, Dr Amir
    Emodi, Omri
    Rachmiel, Adi
    Shilo, Dekel
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2024, 52 (04) : 491 - 502
  • [40] Porous polyethylene implants with embedded titanium mesh: Use in orbital fracture repair and computed tomography visualization
    Duss, CV
    Langer, PD
    Turbin, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46