Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy

被引:1
|
作者
Consorti, Giuseppe [1 ]
Betti, Enrico [1 ]
Catarzi, Lisa [1 ,2 ]
机构
[1] Azienda Osped Univ Ospedali Riuniti Ancona, Dept Maxillofacial Surg, Umberto, Italy
[2] Univ Siena, Dept Maxillofacial Surg, Siena, Italy
关键词
Computer -assisted surgery; Orbital fracture; Blow-out fracture; Customized orbital implant; Preformed titanium mesh; Intraoperative navigation; FLOOR;
D O I
10.1016/j.jcms.2024.02.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to compare the accuracy of inferomedial orbital fracture restoration using customized orbital implant versus 3D preformed titanium mesh. Patients were divided into two groups. Group 1 underwent surgery with customized orbital implants and intraoperative navigation, while group 2 was treated using 3D preformed titanium meshes with preoperative virtual surgical planning (VSP) and intraoperative navigation. Reconstruction accuracy was assessed by: (1) comparing the postoperative reconstruction mesh position with the preoperative VSP; and (2) measuring the difference between the reconstructed and unaffected orbital volume. Pre- and postoperative diplopia and enophthalmos were also evaluated. Fifty-two patients were enrolled (25 in group 1 vs 27 in group 2). The mean difference between final plate position and ideal digital plan was 0.62 mm (SD = 0.235) in group 1 and 0.69 mm (SD = 0.246) in group 2, with no statistical difference between the groups ( p = 0.282). The mean volume differences between the reconstructed and unaffected orbits were 0.95 ml and 1.02 ml in group 1 and group 2, respectively, with no significant difference between the groups ( p = 0.860). Overall clinical improvements, as well as complications, were similar. 3D preformed titanium meshes can reconstruct inferomedial fractures with the same accuracy as customized implants. Therefore, in clinical practice, it is recommended to use 3D preformed meshes for this type of fracture due to their excellent results and the potential for reducing time and costs.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 50 条
  • [21] Orbital Wall Reconstruction with Titanium Mesh: Retrospective Study of 24 Patients
    Gabrielli, Mario Francisco
    Monnazzi, Marcelo Silva
    Passeri, Luis Augusto
    Carvalho, Waldner Ricardo
    Gabrielli, Marisa
    Hochuli-Vieira, Eduardo
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2011, 4 (03) : 151 - 156
  • [22] Accuracy of Orbital Shape Reconstruction-Comparative Analysis of Errors in Implant Shape Versus Implant Positioning: A Cadaveric Study
    Hardisty, Michael
    Wei, Yuan Tao
    Hontscharuk, Rayisa
    Ibrahimi, Amani
    Antonyshyn, Oleh
    Edwards, Glenn
    Mainprize, James G.
    Whyne, Cari M.
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (06) : 1727 - 1731
  • [23] Presurgical Virtual Planning and Intraoperative Navigation with 3D-Preformed Mesh: A New Protocol for Primary Orbital Fracture Reconstruction
    Consorti, Giuseppe
    Monarchi, Gabriele
    Catarzi, Lisa
    LIFE-BASEL, 2024, 14 (04):
  • [24] Accuracy of globe-sparing orbital reconstruction using individually bent titanium mesh: A comparative study
    Soh, Hui Yuh
    Sun, Qian
    Hu, Lei-Hao
    Wang, Yang
    Mao, Chi
    Peng, Xin
    Zhang, Wen-Bo
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (06): : 1971 - 1978
  • [25] Does Intraoperative Navigation Improve Implant Position Accuracy in Orbital Fracture Repair?
    Parameswaran, Anantanarayanan
    Pandey, Meenakshi
    Panneerselvam, Elavenil
    Nisar, Sonam P.
    Bachiavathy, Varsha
    Mukherjee, Bipasha
    FACIAL PLASTIC SURGERY & AESTHETIC MEDICINE, 2024, 26 (05) : 626 - 630
  • [26] Accuracy and Predictability in Use of AO Three-Dimensionally Preformed Titanium Mesh Plates for Posttraumatic Orbital Reconstruction: A Pilot Study
    Scolozzi, Paolo
    Momjian, Armen
    Heuberger, Joris
    Andersen, Elene
    Broome, Martin
    Terzic, Andrej
    Jaques, Bertrand
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (04) : 1108 - 1113
  • [27] 3D Reconstruction in Orbital Proximity Operations
    Dziura, Martin
    Wiese, Tim
    Harder, Jan
    2017 IEEE AEROSPACE CONFERENCE, 2017,
  • [28] Differences between medpor monotherapy and a combination of titanium mesh with medpor in orbital fracture repair
    Zuo, Jing
    Hu, Tianming
    Zhang, Zhiqiang
    Hua, Lei
    Wu, Hao
    Zhong, Lu
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (10): : 7718 - 7725
  • [29] Orbital Reconstruction Using a Polyetheretherketone Patient-Specific Implant After Removal of a Mucocele Developing After Orbital Fracture Repair
    Lee, Junho
    Choi, Young Jae
    Rha, Eun Young
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (08) : 2321 - 2322
  • [30] Low-Cost 3D Printing Orbital Implant Templates in Secondary Orbital Reconstructions
    Callahan, Alison B.
    Campbell, Ashley A.
    Petris, Carisa
    Kazim, Michael
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 33 (05): : 376 - 380