Electrochemical determination of ibuprofen by batch-injection analysis using a BORON-doped ultrananocrystalline diamond electrode

被引:2
|
作者
Prete, Maiyara Carolyne [1 ]
da Rocha, Luana Rianne [1 ]
Segatelli, Mariana Gava [1 ]
Medeiros, Roberta Antigo [1 ]
Swain, Greg M. [2 ]
Teixeira Tarley, Cesar Ricardo [1 ,3 ,4 ]
机构
[1] State Univ Londrina UEL, Dept Chem, Londrina, PR, Brazil
[2] Michigan State Univ, Dept Chem, E Lansing, MI USA
[3] Univ Estadual Campinas, UNICAMP, Natl Inst Sci & Technol INCT Bioanalyt, Inst Chem,Dept Analyt Chem, Campinas, SP, Brazil
[4] State Univ Londrina UEL, Dept Chem, Exacts Sci Ctr, Highway Celso Garcia Cid,PR 445 Km 380, BR-86050482 Londrina, PR, Brazil
关键词
amperometry; batch injection analysis; boron-doped ultrananocrystalline diamond; ibuprofen; pharmaceutical samples; quality control; WALLED CARBON NANOTUBES; VOLTAMMETRIC DETERMINATION; OXIDATION; SPECTROPHOTOMETRY; ELECTROPHORESIS;
D O I
10.1002/elan.202400121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the evaluation of a boron-doped ultrananocrystalline diamond (BD-UNCD) electrode for the determination of ibuprofen (IBU) in pharmaceutical formulations using batch-injection analysis with amperometric detection (BIA-AD) is presented. The BD-UNCD electrode was characterized by Raman spectroscopy and the electrochemical measurements were carried out before and after anodic pretreatment. An improved electrochemical response for IBU oxidation was observed using BD-UNCD as compared to commercial boron-doped diamond electrode. The optimized method based on the BIA-AD system was carried out by using 2.0 V as the detection potential, a dispensing rate of 211.9 mu L s-1, and an injection volume of 40 mu L in an electrochemical cell containing 30.0 mL of 1.0 mol L-1 HClO4 as the supporting electrolyte. The proposed method provided an analytical curve within a linear dynamic range from 1.84 to 20.0 mu mol L-1 (R2=0.9967) and a limit of detection of 0.55 mu mol L-1. The intra-day (n=10) and inter-day (n=2) precisions for IBU concentrations of 5.0 and 10.0 mu mol L-1 assessed as relative standard deviation (%RSD) ranged from 2.65 to 5.84 %. The accuracy of the method was assessed through the determination of IBU in pharmaceutical samples (tablets and solutions), yielding results that were consistent with those obtained through the comparative method (HPLC-DAD).
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Simultaneous Determination of Paracetamol and Ibuprofen in Pharmaceutical Samples by Differential Pulse Voltammetry Using a Boron-Doped Diamond Electrode
    Lima, Amanda B.
    Torres, Livia M. F. C.
    Guimaraes, Carlos F. R. C.
    Verly, Rodrigo M.
    da Silva, Leonardo M.
    Carvalho Junior, Alvaro D.
    dos Santos, Wallans T. P.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2014, 25 (03) : 478 - 483
  • [42] Porous boron-doped diamond/CNT electrode as electrochemical sensor for flow-injection analysis applications
    Lourencao, Bruna C.
    Pinheiro, Romario A.
    Silva, Tiago A.
    Corat, Evaldo J.
    Fatibello-Filho, Orlando
    DIAMOND AND RELATED MATERIALS, 2017, 74 : 182 - 190
  • [43] Electroanalytical determination of estriol hormone using a boron-doped diamond electrode
    Santos, Keliana D.
    Braga, Otoniel C.
    Vieira, Iolanda C.
    Spinelli, Almir
    TALANTA, 2010, 80 (05) : 1999 - 2006
  • [44] Simultaneous Determination of Caffeine, Ibuprofen, and Paracetamol by Flow-injection Analysis with Multiple-pulse Amperometric Detection on Boron-doped Diamond Electrode
    Chaves, Sandro C.
    Aguiar, Priscila N. C.
    Torres, Livia M. F. C.
    Gil, Eric S.
    Luz, Rita C. S.
    Damos, Flavio S.
    Munoz, Rodrigo A. A.
    Richter, Eduardo M.
    dos Santos, Wallans T. P.
    ELECTROANALYSIS, 2015, 27 (12) : 2785 - 2791
  • [45] An advanced approach for electrochemical sensing of ibuprofen in pharmaceuticals and human urine samples using a bare boron-doped diamond electrode
    Svorc, Lubomir
    Strezova, Ivana
    Kianickova, Kristina
    Stankovic, Dalibor M.
    Otrisal, Pavel
    Samphao, Anchalee
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 822 : 144 - 152
  • [46] Electroanalytical determination of the linuron herbicide using a cathodically pretreated boron-doped diamond electrode: comparison with a boron-doped diamond electrode modified with platinum nanoparticles
    Figueiredo-Filho, Luiz C. S.
    Sartori, Elen R.
    Fatibello-Filho, O.
    ANALYTICAL METHODS, 2015, 7 (02) : 643 - 649
  • [47] The analysis of estrogenic compounds by flow injection analysis with amperometric detection using a boron-doped diamond electrode
    Brocenschi, Ricardo F.
    Rocha-Filho, Romeu C.
    Duran, Boris
    Swain, Greg M.
    TALANTA, 2014, 126 : 12 - 19
  • [48] Electrochemical Determination of Ciclopirox Olamine by Using Boron-Doped Diamond Electrode Modified with Overoxidized Polypyrrole Film
    Mielech-Lukasiewicz, Katarzyna
    Domalewska, Milena
    ELECTROCATALYSIS, 2021, 12 (03) : 283 - 294
  • [49] Electrochemical Determination of Ciclopirox Olamine by Using Boron-Doped Diamond Electrode Modified with Overoxidized Polypyrrole Film
    Katarzyna Mielech-Łukasiewicz
    Milena Domalewska
    Electrocatalysis, 2021, 12 : 283 - 294
  • [50] Simple, rapid, and sensitive electrochemical determination of antithyroid drug methimazole using a boron-doped diamond electrode
    Seyidahmet, Safanur
    Donmez, Fatih
    Yardim, Yavuz
    Senturk, Zuehre
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (05) : 913 - 920