Electrochemical determination of ibuprofen by batch-injection analysis using a BORON-doped ultrananocrystalline diamond electrode

被引:2
|
作者
Prete, Maiyara Carolyne [1 ]
da Rocha, Luana Rianne [1 ]
Segatelli, Mariana Gava [1 ]
Medeiros, Roberta Antigo [1 ]
Swain, Greg M. [2 ]
Teixeira Tarley, Cesar Ricardo [1 ,3 ,4 ]
机构
[1] State Univ Londrina UEL, Dept Chem, Londrina, PR, Brazil
[2] Michigan State Univ, Dept Chem, E Lansing, MI USA
[3] Univ Estadual Campinas, UNICAMP, Natl Inst Sci & Technol INCT Bioanalyt, Inst Chem,Dept Analyt Chem, Campinas, SP, Brazil
[4] State Univ Londrina UEL, Dept Chem, Exacts Sci Ctr, Highway Celso Garcia Cid,PR 445 Km 380, BR-86050482 Londrina, PR, Brazil
关键词
amperometry; batch injection analysis; boron-doped ultrananocrystalline diamond; ibuprofen; pharmaceutical samples; quality control; WALLED CARBON NANOTUBES; VOLTAMMETRIC DETERMINATION; OXIDATION; SPECTROPHOTOMETRY; ELECTROPHORESIS;
D O I
10.1002/elan.202400121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the evaluation of a boron-doped ultrananocrystalline diamond (BD-UNCD) electrode for the determination of ibuprofen (IBU) in pharmaceutical formulations using batch-injection analysis with amperometric detection (BIA-AD) is presented. The BD-UNCD electrode was characterized by Raman spectroscopy and the electrochemical measurements were carried out before and after anodic pretreatment. An improved electrochemical response for IBU oxidation was observed using BD-UNCD as compared to commercial boron-doped diamond electrode. The optimized method based on the BIA-AD system was carried out by using 2.0 V as the detection potential, a dispensing rate of 211.9 mu L s-1, and an injection volume of 40 mu L in an electrochemical cell containing 30.0 mL of 1.0 mol L-1 HClO4 as the supporting electrolyte. The proposed method provided an analytical curve within a linear dynamic range from 1.84 to 20.0 mu mol L-1 (R2=0.9967) and a limit of detection of 0.55 mu mol L-1. The intra-day (n=10) and inter-day (n=2) precisions for IBU concentrations of 5.0 and 10.0 mu mol L-1 assessed as relative standard deviation (%RSD) ranged from 2.65 to 5.84 %. The accuracy of the method was assessed through the determination of IBU in pharmaceutical samples (tablets and solutions), yielding results that were consistent with those obtained through the comparative method (HPLC-DAD).
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Novel Electrochemical Flow Injection Procedure for Albendazole Determination using Boron-doped Diamond thin Film Electrode
    Janhom, Watthanachaiyapong
    Rannurags, Narabhats
    Kongsakphaisal, Arunee
    Sirisungworwong, Wasan
    Liawruangrath, Saisunee
    JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 74 (05) : 513 - 519
  • [12] Novel Electrochemical Flow Injection Procedure for Albendazole Determination using Boron-doped Diamond thin Film Electrode
    Narabhats Watthanachaiyapong Janhom
    Arunee Rannurags
    Wasan Kongsakphaisal
    Saisunee Sirisungworwong
    Journal of Analytical Chemistry, 2019, 74 : 513 - 519
  • [13] Electrochemical quantification of propoxur using a boron-doped diamond electrode
    Guimaraes Selva, Thiago Matheus
    Longo Cesar Paixao, Thiago Regis
    DIAMOND AND RELATED MATERIALS, 2016, 66 : 113 - 118
  • [14] Simultaneous determination of captopril and hydrochlorothiazide on boron-doped diamond electrode by batch injection analysis with multiple pulse amperometric detection
    Gimenes, Denise Tofanello
    Marra, Mariana Cardoso
    de Freitas, Jhonys Machado
    Abarza Munoz, Rodrigo Alejandro
    Richter, Eduardo Mathias
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 212 : 411 - 418
  • [15] A simple and fast batch injection analysis method for simultaneous determination of phenazopyridine, sulfamethoxazole, and trimethoprim on boron-doped diamond electrode
    Pereira, Polyana Fernandes
    da Silva, Weberson Pereira
    Abarza Munoz, Rodrigo Alejandro
    Richter, Eduardo Mathias
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 766 : 87 - 93
  • [16] Toward a Boron-Doped Ultrananocrystalline Diamond Electrode Based Dielectrophoretic Preconcentrator
    Zhang, Wenli
    Radadia, Adarsh D.
    ANALYTICAL CHEMISTRY, 2016, 88 (05) : 2605 - 2613
  • [17] Fast and simultaneous determination of nimesulide and paracetamol by batch injection analysis with amperometric detection on bare boron-doped diamond electrode
    Pereira, Polyana Fernandes
    Marra, Mariana Cardoso
    Lima, Amanda Barbosa
    Pio dos Santos, Wallans Torres
    Abarza Munoz, Rodrigo Alejandro
    Richter, Eduardo Mathias
    DIAMOND AND RELATED MATERIALS, 2013, 39 : 41 - 46
  • [18] Electrochemical Characterization and Voltammetric Determination of Methylisothiazolinone on a Boron-Doped Diamond Electrode
    Jakubczyk, Magdalena
    Michalkiewicz, Slawomir
    Skorupa, Agata
    Krajcarz, Kinga
    MOLECULES, 2022, 27 (24):
  • [19] Electrochemical oxidation and electroanalytical determination of xylitol at a boron-doped diamond electrode
    Lourenco, Anabel S.
    Sanches, Fatima A. C.
    Magalhaes, Renata R.
    Costa, Daniel J. E.
    Ribeiro, Williame F.
    Bichinho, Katia M.
    Salazar-Banda, Giancarlo R.
    Araujo, Mario C. U.
    TALANTA, 2014, 119 : 509 - 516
  • [20] Electrochemical Sensor Based on Boron-Doped Diamond Electrode for Determination of Phosphate
    Xu, Yu-Hao
    Wei, Sheng-Nan
    Wang, Yue-Kun
    Xiong, Chen-Yu
    Yong, Xie
    Han, Ming-Jie
    Ri, Wang
    Chao, Bian
    Xia, Shan-Hong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (06)