Electrochemical determination of ibuprofen by batch-injection analysis using a BORON-doped ultrananocrystalline diamond electrode

被引:2
|
作者
Prete, Maiyara Carolyne [1 ]
da Rocha, Luana Rianne [1 ]
Segatelli, Mariana Gava [1 ]
Medeiros, Roberta Antigo [1 ]
Swain, Greg M. [2 ]
Teixeira Tarley, Cesar Ricardo [1 ,3 ,4 ]
机构
[1] State Univ Londrina UEL, Dept Chem, Londrina, PR, Brazil
[2] Michigan State Univ, Dept Chem, E Lansing, MI USA
[3] Univ Estadual Campinas, UNICAMP, Natl Inst Sci & Technol INCT Bioanalyt, Inst Chem,Dept Analyt Chem, Campinas, SP, Brazil
[4] State Univ Londrina UEL, Dept Chem, Exacts Sci Ctr, Highway Celso Garcia Cid,PR 445 Km 380, BR-86050482 Londrina, PR, Brazil
关键词
amperometry; batch injection analysis; boron-doped ultrananocrystalline diamond; ibuprofen; pharmaceutical samples; quality control; WALLED CARBON NANOTUBES; VOLTAMMETRIC DETERMINATION; OXIDATION; SPECTROPHOTOMETRY; ELECTROPHORESIS;
D O I
10.1002/elan.202400121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the evaluation of a boron-doped ultrananocrystalline diamond (BD-UNCD) electrode for the determination of ibuprofen (IBU) in pharmaceutical formulations using batch-injection analysis with amperometric detection (BIA-AD) is presented. The BD-UNCD electrode was characterized by Raman spectroscopy and the electrochemical measurements were carried out before and after anodic pretreatment. An improved electrochemical response for IBU oxidation was observed using BD-UNCD as compared to commercial boron-doped diamond electrode. The optimized method based on the BIA-AD system was carried out by using 2.0 V as the detection potential, a dispensing rate of 211.9 mu L s-1, and an injection volume of 40 mu L in an electrochemical cell containing 30.0 mL of 1.0 mol L-1 HClO4 as the supporting electrolyte. The proposed method provided an analytical curve within a linear dynamic range from 1.84 to 20.0 mu mol L-1 (R2=0.9967) and a limit of detection of 0.55 mu mol L-1. The intra-day (n=10) and inter-day (n=2) precisions for IBU concentrations of 5.0 and 10.0 mu mol L-1 assessed as relative standard deviation (%RSD) ranged from 2.65 to 5.84 %. The accuracy of the method was assessed through the determination of IBU in pharmaceutical samples (tablets and solutions), yielding results that were consistent with those obtained through the comparative method (HPLC-DAD).
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Electrochemical Oxidation of Ibuprofen and Its Voltammetric Determination at a Boron-Doped Diamond Electrode
    Lima, Amanda B.
    Faria, Eric O.
    Montes, Rodrigo H. O.
    Cunha, Rafael R.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    dos Santos, Wallans T. P.
    ELECTROANALYSIS, 2013, 25 (07) : 1585 - 1588
  • [2] Electrochemical determination of bisphenol A using a boron-doped diamond electrode
    Pereira, Gabriel F.
    Andrade, Leonardo S.
    Rocha-Filho, Romeu C.
    Bocchi, Nerilso
    Biaggio, Sonia R.
    ELECTROCHIMICA ACTA, 2012, 82 : 3 - 8
  • [3] ELECTROCHEMICAL DETERMINATION OF DICLOFENAC USING BORON-DOPED DIAMOND ELECTRODE
    Ihos, M.
    Remes, A.
    Manea, F.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2012, 13 (04): : 2096 - 2103
  • [4] Determination of Amlodipine and Atenolol by Batch Injection Analysis with Amperometric Detection on Boron-doped Diamond Electrode
    Silva, Almir A.
    Silva, Luiz A. J.
    Munoz, Rodrigo A. A.
    Oliveira, Aline C.
    Richter, Eduardo M.
    ELECTROANALYSIS, 2016, 28 (07) : 1455 - 1461
  • [5] Electrochemical determination of melatonin hormone using a boron-doped diamond electrode
    Levent, Abdulkadir
    DIAMOND AND RELATED MATERIALS, 2012, 21 : 114 - 119
  • [6] Electrochemical determination of cephalosporins using a bare boron-doped diamond electrode
    Feier, Bogdan
    Gui, Ana
    Cristea, Cecilia
    Sandulescu, Robert
    ANALYTICA CHIMICA ACTA, 2017, 976 : 25 - 34
  • [7] Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
    Niedzialkowski, P.
    Cebula, Z.
    Malinowska, N.
    Bialobrzeska, W.
    Sobaszek, M.
    Ficek, M.
    Bogdanowicz, R.
    Anand, J. Sein
    Ossowski, T.
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 308 - 314
  • [8] FAST AND SIMULTANEOUS DETERMINATION OF SULFAMETHOXAZOLE AND TRIMETHOPRIM USING BATCH INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION AND BORON-DOPED DIAMOND ELECTRODE
    Pereira, Polyana Fernandes
    da Silva, Weberson Pereira
    Abarza Munoz, Rodrigo Alejandro
    Richter, Eduardo Mathias
    QUIMICA NOVA, 2015, 38 (05): : 663 - 668
  • [9] Electrochemical analysis of chloramphenicol using boron-doped diamond electrode applied to a flow-injection system
    Chuanuwatanakul, Suchada
    Chailapakul, Orawon
    Motomizu, Shoji
    ANALYTICAL SCIENCES, 2008, 24 (04) : 493 - 498
  • [10] Electrochemical Analysis of Chloramphenicol Using Boron-doped Diamond Electrode Applied to a Flow-Injection System
    Suchada Chuanuwatanakul
    Orawon Chailapakul
    Shoji Motomizu
    Analytical Sciences, 2008, 24 : 493 - 498