Sonography in the diagnosis of peri-implant bone defects: An in vitro study on native human mandibles

被引:0
|
作者
Bykhovsky, Igor [1 ]
Hildner, Alexander [2 ]
Kripfgans, Oliver D. [3 ]
Mengel, Reiner [1 ]
机构
[1] Philipps Univ Marburg Lahn, Sch Dent Med, Dept Prosthet Dent, Georg Voigt Str 3, D-35039 Marburg, Germany
[2] Alcedis GmbH, Giessen, Germany
[3] Univ Michigan, Dept Radiol, Ann Arbor, MI USA
关键词
dental implant; diagnostics; human cadaver study; peri-implant bone defects; sonography; DIGITAL VOLUME TOMOGRAPHY; ACCURACY; HEALTH; PIG;
D O I
10.1111/clr.14302
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of this study on native human cadavers was to compare clinical, sonographic, and radiological measurements of fenestrations, dehiscences, and 3-wall bone defects on implants. Materials and Methods The examination was carried out on five human mandibles. After the insertion of 27 implants, dehiscences (n = 14), fenestrations (n = 7) and 3-wall bone defects (n = 6) were prepared in a standardized manner. The direct measurement of the bone defects was carried out with a periodontal probe and the radiological examination was carried out using digital volume tomography (DVT). The ultrasound examination (US) was performed using a clinical 24-MHz US imaging probe. Means and standard deviations of the direct, US, and DVT measurements were calculated. Measurements were statistically compared using the Pearson correlation coefficient and Bland-Altman analysis. Results Bone defects were on average 3.22 +/- 1.58 mm per direct measurement, 2.90 +/- 1.47 mm using US, and 2.99 +/- 1.52 mm per DVT assessment. Pairwise correlations of these measurements were R = .94 (p < .0001) between direct and US, R = .95 (p < .0001) between DVT and US, and R = .96 (p < .0001) between direct and DVT. The mean differences of the measurements (and 95% CI) between direct and US was 0.41 (-0.47 to 1.29), US and DVT 0.33 (-0.30 to 0.97), and direct and DVT 0.28 (-0.50 to 1.07). Conclusion All peri-implant bone defects could be identified and sonographically measured. US measurements showed a strong correlation with direct and DVT measurements. The sonographic measurement accuracy was highest for dehiscences, followed by fenestrations and 3-wall bone defects.
引用
收藏
页码:1128 / 1137
页数:10
相关论文
共 50 条
  • [1] Digital volume tomography in the diagnosis of peri-implant defects: An in vitro study on native pig mandibles
    Mengel, Reiner
    Kruse, Bjoern
    Flores-de-Jacoby, Lavin
    JOURNAL OF PERIODONTOLOGY, 2006, 77 (07) : 1234 - 1241
  • [2] Detection of peri-implant bone defects with different radiographic techniques - a human cadaver study
    Kuehl, Sebastian
    Zuercher, Silvia
    Zitzmann, Nicola U.
    Filippi, Andreas
    Payer, Michael
    Dagassan-Berndt, Dorothea
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (05) : 529 - 534
  • [3] Bone Substitutes for Peri-Implant Defects of Postextraction Implants
    Santos, Pamela Leticia
    Gunnelli, Jessica Lemos
    Telles, Cristino da Silva
    Betoni Junior, Walter
    Okamoto, Roberta
    Buchignani, Vivian Chiacchio
    Queiroz, Thallita Pereira
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2013, 2013
  • [4] Microbial findings of deep peri-implant bone defects
    Augthun, M
    Conrads, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1997, 12 (01) : 106 - 112
  • [5] Human Autopsy Study of Peri-implant Dehiscence Defects with Guided Bone Regeneration: A Case Report
    Cha, Jae-Kook
    Sanz, Mariano
    Jung, Ui-Won
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2019, 39 (04) : 517 - 525
  • [6] Primary stability of implants with peri-implant bone defects of various widths: an in vitro investigation
    Yim, Hyun-Jin
    Lim, Hyun-Chang
    Hong, Ji-Youn
    Shin, Seung-Il
    Chung, Jong-Hyuk
    Herr, Yeek
    Shin, Seung-Yun
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2019, 49 (01): : 39 - 46
  • [7] Endodontic peri-implant defects
    Wadia R.
    British Dental Journal, 2020, 228 (4) : 253 - 253
  • [8] Digital volume tomography in the diagnosis of periodontal defects: An in vitro study on native pig and human mandibles
    Mengel, R
    Candir, M
    Shiratori, K
    Flores-De-Jacoby, L
    JOURNAL OF PERIODONTOLOGY, 2005, 76 (05) : 665 - 673
  • [9] Bone formation in peri-implant defects grafted with microparticles: a pilot animal experimental study
    Moest, Tobias
    Koehler, Franz
    Prechtl, Christopher
    Schmitt, Christian
    Watzek, Georg
    Schlegel, Karl Andreas
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2014, 41 (10) : 990 - 998
  • [10] Treatment of Peri-implant Bone Defects with Platelet-Rich Fibrin
    Hamzacebi, Burak
    Oduncuoglu, Bahar
    Alaaddinoglu, Emine Elif
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2015, 35 (03) : 415 - 422