Development of an FPGA-Based Pulse-Height Analyzer for Scintillation Detectors in Gamma Energy Spectroscopy

被引:1
|
作者
Hai, Vo Hong [1 ]
机构
[1] Vietnam Natl Univ Ho Chi Minh City, Univ Sci, 227 Nguyen Cu,Ward 4, Ho Chi Minh City, Vietnam
关键词
pulse height analyzer; FPGA; NaI(Tl) detector; gamma energy spectra;
D O I
10.1002/tee.24131
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study presents the development of a Pulse Height Analyzer (PHA) using an FPGA-based hardware platform, specifically the National Instruments MyRIO embedded device, for radiation detectors. Electronic pulses generated by the detector when exposed to radiation are triggered, digitized, and transferred to a data buffer. A pulse height analysis tool categorizes these pulses and stores pulse-height information in registers or channels, enabling the construction of a pulse-height distribution. The data of pulse-height distribution is then recorded on a computer via a user-friendly interface. The Pulse Height Analyzer was implemented using a 3-inch by 3-inch NaI(Tl) scintillation detector for gamma energy measurements, employing standard radioisotopes Na-22 and Co-60. Gamma energy spectra were acquired and analyzed. Our results demonstrate that the achieved energy resolution is comparable to that of the commercial Pulse Height Analyzers, such as EASY-MCA 2K, a product of AMETEK Inc. (c) 2024 Institute of Electrical Engineer of Japan and Wiley Periodicals LLC.
引用
收藏
页码:1737 / 1742
页数:6
相关论文
共 50 条
  • [41] Use of Pulse-Height Spectroscopy to Characterize the Hole Conduction Mechanism of a Polyimide Blocking Layer Used in Amorphous-Selenium Radiation Detectors
    Camlica, Ahmet
    Kabir, M. Zahangir
    Liang, Jerry
    Levine, Peter M.
    Lee, Denny L.
    Karim, Karim S.
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2020, 67 (02) : 633 - 639
  • [42] RAPID ANALYSIS OF SHORT-LIVED NEUTRON-IRRADIATION PRODUCTS USING A MINICOMPUTER-BASED PULSE-HEIGHT ANALYZER
    ANDERSON, DL
    FAILEY, MP
    ZOLLER, WH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 28 : 62 - 63
  • [43] SIMPLE-MODEL FOR PREDICTION OF GAMMA-RAY PULSE-HEIGHT SPECTRA FOR RIGHT-CIRCULAR CYLINDRICAL SODIUM IODIDE CRYSTAL DETECTORS
    GARDNER, RP
    NUCLEAR INSTRUMENTS & METHODS, 1976, 138 (02): : 287 - 291
  • [44] METHOD TO OBTAIN UNCHANGED ENERGY CALIBRATION IN PULSE-HEIGHT ANALYZER FOR A GAS FILLED DELTA-E-PROPORTIONAL COUNTER AT DIFFERENT FILLING PRESSURES
    CHATTERJEE, ML
    NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (02): : 275 - 277
  • [45] Determination of the dose rate from the pulse-height spectra of an airborne gamma-ray spectrometer based on an unmanned aerial vehicle
    Gavrilov, S. L.
    Pimenov, A. E.
    Shvedov, A. M.
    Aron, D. V.
    Dyakov, S. V.
    ATOMIC ENERGY, 2023, 135 (1-2) : 74 - 80
  • [46] Evaluation of gamma-ray strength function based on measured gamma-ray pulse-height spectra in time-of-flight neutron capture experiments
    Iwamoto, Nobuyuki
    Nakamura, Shoji
    Kimura, Atsushi
    Katabuchi, Tatsuya
    Rovira, Gerard
    Kaoru, Y. Hara
    Iwamoto, Osamu
    ND 2019: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, 2020, 239
  • [47] In-house development of an FPGA-based MCA8K for gamma-ray spectrometer
    Dang Lanh
    Pham Ngoc Son
    Nguyen An Son
    SPRINGERPLUS, 2014, 3
  • [48] RISC32-LP: Low-Power FPGA-Based IoT Sensor Nodes With Energy Reduction Program Analyzer
    Tan, Beng-Liong
    Mok, Kai-Ming
    Chang, Jing-Jing
    Lee, Wai-Kong
    Hwang, Seong Oun
    IEEE INTERNET OF THINGS JOURNAL, 2022, 9 (06) : 4214 - 4228
  • [49] An FPGA-Based Fast Linear Discharge Readout Scheme Enabling Simultaneous Time and Energy Measurements for TOF-PET Detectors
    Kong, Xiaoguang
    Wang, Yonggang
    Wang, Liwei
    Xiao, Yong
    Kuang, Jie
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (01) : 30 - 36
  • [50] Development of gamma spectroscopy employing NaI(Tl) detector 3 inch x 3 inch and readout electronic of flash-ADC/FPGA-based technology
    Vo Hong Hai
    Nguyen Quoc Hung
    Bui Tuan Khai
    KERNTECHNIK, 2015, 80 (02) : 180 - 183