The fabrication and characterization of direct conversion flat panel X-ray imager with TlBr film

被引:2
|
作者
Hamdan, Moh [1 ]
Shimazoe, Kenji [1 ]
Takahashi, Hiroyuki [1 ]
Nogami, Mitsuhiro [2 ]
Hitomi, Keitaro [2 ]
Asakura, Shinya [3 ]
Tsunashima, Takanori [3 ]
Nakamura, Takashi [3 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Nucl Engn & Management, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1138656, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Sendai 9808579, Japan
[3] Japan Display Inc, R&D Div, Device Dev Dept, Mobara Plant, 3300 Hayano, Mobara, Chiba 2978622, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2024年 / 1064卷
关键词
TlBr film; LTPS TFT; FPD; X-ray imaging; DETECTOR; FEASIBILITY; PERFORMANCE;
D O I
10.1016/j.nima.2024.169372
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The novel direct conversion flat panel detectors (FPDs) utilizing thallium bromide (TlBr) films are developed and characterized in this study. Thin TlBr films, deposited using an evaporation technique, achieved thicknesses of 10 mu m and 50 mu m. A pixel sensor array, with a pixel size of 235 x 235 mu m(2) and a sensitive area of 29.61 x 39.48 mm(2), was developed using low-temperature polysilicon thin-film transistor (LTPS TFT) technology as the initial study to explore performance characteristics of developed imaging system. The TlBr film was characterized based on the current-voltage (I-V) profile, showing a resistivity of 2.78 x 1010 Omega.cm. The LTPS TFT showed a leakage current of about 10-13 A, while the noise of TlBr FPD system was around 104 e(-) rms, primarily limited by the readout system. The detector system was characterized using radiation from an X-ray tube with a voltage in the range of 30 kV-100 kV and a current of 2 mA, involving an X-ray test chart as the object with the processing time of 18.15-18.30 ms per frame. Based on the contrast and contrast-to-noise ratio (CNR) values, the 10 mu m and 50 mu m TlBr FPD clearly captured the image in operation between 30 kV and 100 kV. The 50 mu m TlBr FPD demonstrated improved sensitivity, showing pixel values with 10 times higher intensity and enhanced line pair detail at 30 kV X-ray operation. The 10 mu m TlBr achieved spatial resolution of 267 mu m full width at half maximum (FWHM), while the 50 mu m TlBr achieved 250 mu m FWHM. In the X-ray imaging demonstration, the shape and structure of anchovy was clearly distinguished. The TlBr film FPD presents promising potential for a room temperature X-ray imager.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Direct-conversion flat-panel X-ray image detectors
    Kasap, SO
    Rowlands, JA
    IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 2002, 149 (02): : 85 - 96
  • [2] Dosimetry of X-ray fields with an amorphous silicon flat panel imager
    Wendling, M
    McDermott, LN
    Sonke, JJ
    Louwe, RJW
    Van Herk, MB
    Mijnheer, BJ
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S26 - S27
  • [3] Compound Poisson Noise Verification for X-ray Flat Panel Imager
    Hsieh, Ho-Hui
    Ni, Yu-Ching
    Tseng, Sheng-Pin
    Tseng, Fan-Pin
    Chen, Liang-Cheng
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST) PROCEEDINGS, 2015, : 422 - 426
  • [4] Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
    Kasap, Safa
    Frey, Joel B.
    Belev, George
    Tousignant, Olivier
    Mani, Habib
    Greenspan, Jonathan
    Laperriere, Luc
    Bubon, Oleksandr
    Reznik, Alla
    DeCrescenzo, Giovanni
    Karim, Karim S.
    Rowlands, John A.
    SENSORS, 2011, 11 (05) : 5112 - 5157
  • [5] Direct conversion flat panel x-ray imaging: reduction of noise by presampling filtration
    Rowlands, JA
    Ji, WG
    Zhao, W
    Lee, DL
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 446 - 455
  • [6] Investigation of a direct conversion flat panel imager for portal imaging
    Pang, G
    Lee, DL
    Rowlands, JA
    MEDICAL PHYSICS, 2001, 28 (10) : 2121 - 2128
  • [7] Direct-conversion flat-panel X-ray image sensors for digital radiography
    Kasap, SO
    Rowlands, JA
    PROCEEDINGS OF THE IEEE, 2002, 90 (04) : 591 - 604
  • [8] Characterization of TlBr for X-ray and γ-ray detector applications
    Kostamo, P.
    Shorohov, M.
    Gostilo, V.
    Sipila, H.
    Kozlov, V.
    Lisitsky, I.
    Kuznetsov, M.
    Lankinen, A.
    Danilewsky, A. N.
    Lipsanen, H.
    Leskela, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 129 - 131
  • [9] X-ray photoconductors and stabilized a-Se for direct conversion digital flat-panel X-ray image-detectors
    Kasap, SO
    Rowlands, JA
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2000, 11 (03) : 179 - 198
  • [10] Bias Polarity Switching-Type TlBr X-Ray Imager
    Takagi, Katsuyuki
    Toyoda, Kohei
    Kase, Hiroki
    Takagi, Toshiyuki
    Tabata, Kento
    Terao, Tsuyoshi
    Morii, Hisashi
    Koike, Akifumi
    Aoki, Toru
    Nogami, Mitsuhiro
    Hitomi, Keitaro
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (09) : 2435 - 2439