Compound Poisson Noise Verification for X-ray Flat Panel Imager

被引:0
|
作者
Hsieh, Ho-Hui [1 ]
Ni, Yu-Ching [1 ]
Tseng, Sheng-Pin [1 ]
Tseng, Fan-Pin [1 ]
Chen, Liang-Cheng [1 ]
机构
[1] Inst Nucl Energy Res, Div Hlth Phys, Taoyuan, Taiwan
来源
2015 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST) PROCEEDINGS | 2015年
关键词
radiography; x-ray detectors; noise; ENERGY-INTEGRATING DETECTORS; RECONSTRUCTION; PERFORMANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Physical effects that contribute to the noise in digital radiography are possible to be represented as overall variance including Poisson statistics of x-rays. For real system, statement of the noise response must be integrated against a spectrum to get the total response to spectral fluence of x-ray, that the detected x-ray follows a compound-Poisson distribution. To verify the noise property of our x-ray flat-panel detector (FPD), we formulate a compound-Poisson based model to verify the image noise statistic from measured data. Results demonstrate that the FPD noise property is independed from the tube voltage; only 1.6% error is occurred by the model fitting. In this case, the noise property of our FPD can accurately be represented as the modeled function.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 50 条
  • [1] Dosimetry of X-ray fields with an amorphous silicon flat panel imager
    Wendling, M
    McDermott, LN
    Sonke, JJ
    Louwe, RJW
    Van Herk, MB
    Mijnheer, BJ
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S26 - S27
  • [2] A new x-ray imaging technique for radiography mode of flat-panel imager
    Suzuki, K.
    Ikeda, S.
    Ueda, K.
    Baba, R.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [3] The fabrication and characterization of direct conversion flat panel X-ray imager with TlBr film
    Hamdan, Moh
    Shimazoe, Kenji
    Takahashi, Hiroyuki
    Nogami, Mitsuhiro
    Hitomi, Keitaro
    Asakura, Shinya
    Tsunashima, Takanori
    Nakamura, Takashi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [5] Investigation into the influence of x-ray scatter on the imaging performance of an x-ray flat panel imager based cone beam volume CT
    Tang, XY
    Ning, R
    Yu, RF
    Conover, D
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 851 - 860
  • [6] A REAL-TIME, FLAT-PANEL, AMORPHOUS-SILICON, DIGITAL X-RAY IMAGER
    ANTONUK, LE
    YORKSTON, J
    HUANG, WD
    SIEWERDSEN, JH
    BOUDRY, JM
    ELMOHRI, Y
    MARX, MV
    RADIOGRAPHICS, 1995, 15 (04) : 993 - 1000
  • [7] ON RADIOTHERAPY DOSE VERIFICATION WITH A FLAT-PANEL IMAGER
    McDermott, L.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S49 - S49
  • [8] Direct conversion flat panel x-ray imaging: reduction of noise by presampling filtration
    Rowlands, JA
    Ji, WG
    Zhao, W
    Lee, DL
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 446 - 455
  • [9] Performance quantification of a flat-panel imager in industrial mega-voltage X-ray imaging systems
    Stritt, Carina
    Plamondon, Mathieu
    Hofmann, Jurgen
    Fliseh, Alexander
    Sennhauser, Urs
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 848 : 73 - 80
  • [10] Determination of point spread function for a flat-panel X-ray imager and its application in image restoration
    Jeon, Sungchae
    Cho, Gyuseong
    Huh, Young
    Jin, Seungoh
    Park, Jongduk
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 167 - 171