The fabrication and characterization of direct conversion flat panel X-ray imager with TlBr film

被引:2
|
作者
Hamdan, Moh [1 ]
Shimazoe, Kenji [1 ]
Takahashi, Hiroyuki [1 ]
Nogami, Mitsuhiro [2 ]
Hitomi, Keitaro [2 ]
Asakura, Shinya [3 ]
Tsunashima, Takanori [3 ]
Nakamura, Takashi [3 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Nucl Engn & Management, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1138656, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Sendai 9808579, Japan
[3] Japan Display Inc, R&D Div, Device Dev Dept, Mobara Plant, 3300 Hayano, Mobara, Chiba 2978622, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2024年 / 1064卷
关键词
TlBr film; LTPS TFT; FPD; X-ray imaging; DETECTOR; FEASIBILITY; PERFORMANCE;
D O I
10.1016/j.nima.2024.169372
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The novel direct conversion flat panel detectors (FPDs) utilizing thallium bromide (TlBr) films are developed and characterized in this study. Thin TlBr films, deposited using an evaporation technique, achieved thicknesses of 10 mu m and 50 mu m. A pixel sensor array, with a pixel size of 235 x 235 mu m(2) and a sensitive area of 29.61 x 39.48 mm(2), was developed using low-temperature polysilicon thin-film transistor (LTPS TFT) technology as the initial study to explore performance characteristics of developed imaging system. The TlBr film was characterized based on the current-voltage (I-V) profile, showing a resistivity of 2.78 x 1010 Omega.cm. The LTPS TFT showed a leakage current of about 10-13 A, while the noise of TlBr FPD system was around 104 e(-) rms, primarily limited by the readout system. The detector system was characterized using radiation from an X-ray tube with a voltage in the range of 30 kV-100 kV and a current of 2 mA, involving an X-ray test chart as the object with the processing time of 18.15-18.30 ms per frame. Based on the contrast and contrast-to-noise ratio (CNR) values, the 10 mu m and 50 mu m TlBr FPD clearly captured the image in operation between 30 kV and 100 kV. The 50 mu m TlBr FPD demonstrated improved sensitivity, showing pixel values with 10 times higher intensity and enhanced line pair detail at 30 kV X-ray operation. The 10 mu m TlBr achieved spatial resolution of 267 mu m full width at half maximum (FWHM), while the 50 mu m TlBr achieved 250 mu m FWHM. In the X-ray imaging demonstration, the shape and structure of anchovy was clearly distinguished. The TlBr film FPD presents promising potential for a room temperature X-ray imager.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Selenium-based amorphous silicon flat-panel digital X-ray imager for protein crystallography
    Sultana, Afrin
    Karim, K. S.
    Rowlands, J. A.
    CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2008, 33 (3-4): : 139 - 143
  • [32] An X-ray tomograph based on a flat panel detector
    Constantin, F.
    Pavel, C.
    Bugoi, R.
    Toderas, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 685 - 689
  • [33] Flat-panel detectors in X-ray systems
    Spahn, M
    Heer, V
    Freytag, R
    RADIOLOGE, 2003, 43 (05): : 340 - +
  • [34] Development of flat panel X-ray image sensors
    Izumi, Y.
    Teranuma, O.
    Sato, T.
    Uehara, K.
    Okada, H.
    Tokuda, S.
    Sato, T.
    Shapu Giho/Sharp Technical Journal, 2001, (80): : 25 - 30
  • [35] Characterization of a flat-panel amorphous silicon detector for X-ray computed tomography
    Lee, H.-R.
    Ellingson, W.
    Journal of X-Ray Science and Technology, 2001, 9 (01) : 43 - 53
  • [36] Cation-π interactions enabled water-stable perovskite X-ray flat mini-panel imager
    Wanting Pan
    Yuhong He
    Weijun Li
    Lulu Liu
    Keke Guo
    Jianglei Zhang
    Chao Wang
    Bao Li
    Hu Huang
    Junhu Zhang
    Bai Yang
    Haotong Wei
    Nature Communications, 15
  • [37] X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing
    Cha, Bo Kyung
    Jeon, Seongchae
    Seo, Chang-Woo
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 404 - 409
  • [38] Cation-π interactions enabled water-stable perovskite X-ray flat mini-panel imager
    Pan, Wanting
    He, Yuhong
    Li, Weijun
    Liu, Lulu
    Guo, Keke
    Zhang, Jianglei
    Wang, Chao
    Li, Bao
    Huang, Hu
    Zhang, Junhu
    Yang, Bai
    Wei, Haotong
    NATURE COMMUNICATIONS, 2024, 15 (01)
  • [39] Dilation x-ray imager a new/faster gated x-ray imager for the NIF
    Nagel, S. R.
    Hilsabeck, T. J.
    Bell, P. M.
    Bradley, D. K.
    Ayers, M. J.
    Barrios, M. A.
    Felker, B.
    Smith, R. F.
    Collins, G. W.
    Jones, O. S.
    Kilkenny, J. D.
    Chung, T.
    Piston, K.
    Raman, K. S.
    Sammuli, B.
    Hares, J. D.
    Dymoke-Bradshaw, A. K. L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [40] Fabrication of ZnO Nanowire Cold Cathode Flat-Panel X-ray Source with a Reflective Anode
    Wang, Chengyun
    Zhang, Guofu
    Liu, Qi
    Kang, Song
    Deng, Shaozhi
    Chen, Jun
    NANOMATERIALS, 2024, 14 (18)