A review of switching overvoltage modeling in UHV AC transmission lines

被引:1
|
作者
Reddy, Sheri Abhishek [1 ]
Kumari, M. Sailaja [1 ]
机构
[1] Natl Inst Technol Warangal, Warangal 506004, Telangana, India
关键词
Fault clearing; Fault initiation; Line energization; Line re-energization; Switching overvoltages; UHV AC transmission line; IMPULSE TESTS; INSULATION COORDINATION; STATISTICAL-ANALYSIS; TRANSFORMER MODEL; SURGE ARRESTERS; RISK ANALYSIS; FAILURE RISK; TRANSIENTS; SIMULATION; VOLTAGE;
D O I
10.1016/j.epsr.2024.110902
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This review article on switching overvoltage modelling in UHV AC Transmission lines, provides a state-of-theart analysis of switching overvoltages and their impact on insulation coordination in UHV AC transmission lines. Switching overvoltages, insulation coordination, switching transient modelling tools, and switching surge flashover rate mathematical models are examined in the paper. It also examines modelling concepts, transmission models, insulation coordination for Ultra High Voltage (UHV) versus Extra High Voltage (EHV) lines, simulation scenarios and platforms, and best practices for insulation coordination limited to transmission lines. The methodology involved extensive research, consulting academic journals and conference papers, and modelling switching overvoltages with a case study. Key findings show that transmission tower insulation decreases because actual switching overvoltages take longer time to reach their peak than the critical wave. Every switching action generates a switching overvoltage with a characteristic waveform, which impacts insulation coordination. The work reveals a gap in existing research, which often focuses on overvoltages generated by a few switching events. This review suggests considering overvoltages from primary switching operations for better assessment of insulation coordination. These aspects must be considered in insulation coordination to improve UHV AC transmission line reliability and security.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Modeling of Corona Discharge And Overvoltage Propagation Along Transmission Lines
    Anane, Zahira
    Bayadi, AbdElhafid
    JOURNAL OF POWER TECHNOLOGIES, 2022, 102 (02): : 45 - 55
  • [22] Simulation Study of overvoltage in UHV AC and DC Hybrid System
    Li, Hongwei
    Peng, Ganrong
    2015 IEEE ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC), 2015, : 1215 - 1219
  • [23] Research on overvoltage and fault of a UHV AC/DC hybrid system
    Wang, Yali
    Zou, Liang
    Chen, Yongshuai
    Fang, Shengwei
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2106 - 2111
  • [24] Research on high-voltage reactor compensation of UHV AC transmission lines
    Yi, Qiang
    Zhou, Hao
    Ji, Rong-Rong
    Xu, Qiong-Jing
    Su, Fei
    Sun, Ke
    Chen, Jia-Miao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (20): : 98 - 105
  • [25] Travelling Wave Protection of UHV Half-wavelength AC Transmission Lines
    Zheng Y.
    Si X.
    Wu T.
    Yao G.
    Hong F.
    Zheng X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (18): : 124 - 131
  • [26] Research on power frequency over-voltage in UHV AC transmission lines
    Sun, Ke
    Yi, Qiang
    Dong, Chaowu
    Zhou, Hao
    Dianwang Jishu/Power System Technology, 2010, 34 (12): : 30 - 35
  • [27] Calculation of Induced Voltage and Current on a Crossing Transmission Line under UHV AC Transmission Lines
    Li Yuze
    Kong Xiaofeng
    Zhang Bo
    2019 IEEE ASIA POWER AND ENERGY ENGINEERING CONFERENCE (APEEC 2019), 2019, : 132 - 136
  • [28] Analysis of ground impedance relay operation characteristics for UHV AC transmission lines
    Wang, Bin
    Dong, Xinzhou
    Zhou, Shuangxi
    Bo, Zhiqian
    Klimek, A.
    Caunce, B.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2007, 31 (17): : 45 - 49
  • [29] Study on electromagnetic environment of ±800 kV UHV DC and 1000 kV UHV AC parallel transmission lines
    Wang, Guangzhou
    Yao, Degui
    Zhang, Songyang
    Wang, Donghui
    Wang, Leilei
    Guo, Xing
    Yang, Fan
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [30] Calculation of overvoltage on nearby underground metal pipeline due to the lightning strike on UHV AC transmission line tower
    Qi, Lei
    Yuan, Hui
    Wu, Yan
    Cui, Xiang
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 94 : 54 - 63