Measurements of Arterial Occlusion Pressure Using Hand-Held Devices

被引:4
|
作者
Vehrs, Pat R. [1 ]
Richards, Shay [1 ]
Allen, Josh [1 ]
Barrett, Rachel [1 ]
Blazzard, Chase [1 ]
Burbank, Tyler [1 ]
Hart, Hannah [1 ]
Kasper, Nicole [1 ]
Lacey, Ryan [1 ]
Lopez, Daniela [1 ]
Fellingham, Gilbert W. [2 ]
机构
[1] Brigham Young Univ, Dept Exercise Sci, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Stat, Provo, UT USA
关键词
blood flow restriction; blood flow restriction exercise; pulse oximetry; Doppler; BLOOD-FLOW RESTRICTION; CUFF WIDTH; EXERCISE; HEMODYNAMICS; SEX;
D O I
10.1519/JSC.0000000000004716
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Arterial occlusion pressure (AOP) of the brachial artery was measured simultaneously using Doppler ultrasound (US), a hand-held Doppler (HHDOP), and a pulse oximeter (PO) in the dominant (DOM) and nondominant (NDOM) arms of males (n = 21) and females (n = 23) using continuous (CONT) and incremental (INCR) cuff inflation protocols. A mixed-model analysis of variance revealed significant (p < 0.05) overall main effects between AOP measured using a CONT (115.7 +/- 10.9) or INCR (115.0 +/- 11.5) cuff inflation protocol; between AOP measured using US (116.3 +/- 11.2), HHDOP (115.4 +/- 11.2), and PO (114.4 +/- 11.2); and between males (120.7 +/- 10.6) and females (110.5 +/- 9.4). The small overall difference (1.81 +/- 3.3) between US and PO measures of AOP was significant (p < 0.05), but the differences between US and HHDOP and between HHDOP and PO measures of AOP were not significant. There were no overall differences in AOP between the DOM and NDOM arms. Trial-to-trial variance in US measurements of AOP was not significant when using either cuff inflation protocol but was significant when using HHDOP and PO and a CONT cuff inflation protocol. Bland-Altman plots revealed reasonable limits of agreement for both HHDOP and PO measures of AOP. The small differences in US, HHDOP, and PO measurements of AOP when using CONT or INCR cuff inflation protocols are of minimal practical importance. The choice of cuff inflation protocol is one of personal preference. Hand-held Doppler of PO can be used to assess AOP before using blood flow restriction during exercise.
引用
收藏
页码:873 / 880
页数:8
相关论文
共 50 条
  • [31] HAND-HELD - UPWARD MOBILITY THROUGH HAND-HELD TRANSCEIVERS
    GUSTAFSON, D
    AIR PROGRESS, 1985, 47 (03): : 30 - 32
  • [32] Adaptation of Predictive Models to PDA Hand-Held Devices
    Lin, Edward J.
    Purcell, Thomas B.
    McPheeters, Rick A.
    WESTERN JOURNAL OF EMERGENCY MEDICINE, 2008, 9 (01) : 13 - 19
  • [33] Older People with Access to Hand-Held Devices: Who Are They?
    Shahrokni, Armin
    Mahmoudzadeh, Sanam
    Saeedi, Ramyar
    Ghasemzadeh, Hassan
    TELEMEDICINE AND E-HEALTH, 2015, 21 (07) : 550 - 556
  • [34] Counting Large Flocks of Birds Using Videos Acquired with Hand-Held Devices
    Dash, Amanda
    Albu, Alexandra Branzan
    ADVANCED CONCEPTS FOR INTELLIGENT VISION SYSTEMS (ACIVS 2017), 2017, 10617 : 468 - 478
  • [35] Patient-centered educational intervention using hand-held electronic devices
    Hellmers, N.
    Hanineva, A.
    Stribling, J. C.
    Carter, J.
    Henchliffe, C.
    MOVEMENT DISORDERS, 2016, 31 : S137 - S137
  • [36] Feasibility study of abdominal ultrasound using hand-held devices in homecare services
    Vilanova-Rotllan, Sergi
    Kostov, Belchin
    Martos, M. Jose Giner
    Benavent-Areu, Jaume
    Siso-Almirall, Antoni
    MEDICINA CLINICA, 2022, 158 (08): : 361 - 365
  • [37] Visual fatigue occurrence time when using hand-held intelligent devices
    Hsin-Chieh Wu
    Min-Chi Chiu
    Chia-Wei Peng
    Journal of Ambient Intelligence and Humanized Computing, 2016, 7 : 829 - 835
  • [38] Visual fatigue occurrence time when using hand-held intelligent devices
    Wu, Hsin-Chieh
    Chiu, Min-Chi
    Peng, Chia-Wei
    JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2016, 7 (06) : 829 - 835
  • [39] ARE HAND-HELD TCD MEASUREMENTS ACCEPTABLE FOR ESTIMATES OF CBFv?
    Saeed, Nazia P.
    Panerai, Ronney B.
    Robinson, Thompson G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (10): : 1839 - 1844
  • [40] Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer
    Janssen, Jessie C.
    Le-Ngoc, Lan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (09): : 1541 - 1547