Deformable anthropomorphic pelvis phantom for dose accumulation verification

被引:1
|
作者
Wong, Yun Ming [1 ]
Koh, Calvin Wei Yang [2 ,7 ]
Lew, Kah Seng [1 ,2 ]
Chua, Clifford Ghee Ann [2 ,7 ]
Yeap, Ping Lin [2 ,4 ]
Zhang, Ee Teng [5 ,6 ]
Ong, Ashley Li Kuan [2 ,7 ]
Tuan, Jeffrey Kit Loong [2 ,7 ]
Ng, Bing Feng [5 ]
Lew, Wen Siang [1 ]
Lee, James Cheow Lei [1 ,2 ]
Tan, Hong Qi [1 ,2 ,3 ,7 ]
机构
[1] Nanyang Technol Univ, Div Phys & Appl Phys, Singapore, Singapore
[2] Natl Canc Ctr Singapore, Div Radiat Oncol, Singapore, Singapore
[3] Duke NUS Med Sch, Oncol Acad Clin Programme, Singapore, Singapore
[4] Univ Cambridge, Dept Oncol, Cambridge, England
[5] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Nanyang, Singapore
[6] Nanyang Technol Univ, Singapore Ctr Printing 3D, Singapore, Singapore
[7] Natl Canc Ctr Singapore, Lab Ai3, Singapore, Singapore
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 12期
关键词
deformable image registration; adaptive radiotherapy; dice similarity coefficient; target registration error; dose accumulation; 3D printing; deformable anthropomorphic phantom; ADAPTIVE RADIOTHERAPY; IMAGE REGISTRATION; PROSTATE MOTION; INTRAFRACTION MOTION; RADIATION-THERAPY; VALIDATION; ACCURACY; EXPERIENCE; FRAMEWORK; MARGINS;
D O I
10.1088/1361-6560/ad52e4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The validation of deformable image registration (DIR) for contour propagation is often done using contour-based metrics. Meanwhile, dose accumulation requires evaluation of voxel mapping accuracy, which might not be accurately represented by contour-based metrics. By fabricating a deformable anthropomorphic pelvis phantom, we aim to (1) quantify the voxel mapping accuracy for various deformation scenarios, in high- and low-contrast regions, and (2) identify any correlation between dice similarity coefficient (DSC), a commonly used contour-based metric, and the voxel mapping accuracy for each organ. Approach. Four organs, i.e. pelvic bone, prostate, bladder and rectum (PBR), were 3D printed using PLA and a Polyjet digital material, and assembled. The latter three were implanted with glass bead and CT markers within or on their surfaces. Four deformation scenarios were simulated by varying the bladder and rectum volumes. For each scenario, nine DIRs with different parameters were performed on RayStation v10B. The voxel mapping accuracy was quantified by finding the discrepancy between true and mapped marker positions, termed the target registration error (TRE). Pearson correlation test was done between the DSC and mean TRE for each organ. Main results. For the first time, we fabricated a deformable phantom purely from 3D printing, which successfully reproduced realistic anatomical deformations. Overall, the voxel mapping accuracy dropped with increasing deformation magnitude, but improved when more organs were used to guide the DIR or limit the registration region. DSC was found to be a good indicator of voxel mapping accuracy for prostate and rectum, but a comparatively poorer one for bladder. DSC > 0.85/0.90 was established as the threshold of mean TRE > 0.3 cm for rectum/prostate. For bladder, extra metrics in addition to DSC should be considered. Significance. This work presented a 3D printed phantom, which enabled quantification of voxel mapping accuracy and evaluation of correlation between DSC and voxel mapping accuracy.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Creation of an anthropomorphic CT head phantom for verification of image segmentation
    Holmes, Robin B.
    Negus, Ian S.
    Wiltshire, Sophie J.
    Thorne, Gareth C.
    Young, Peter
    MEDICAL PHYSICS, 2020, 47 (06) : 2380 - 2391
  • [32] Deformable Registration for Dose Accumulation
    Chetty, Indrin J.
    Rosu-Bubulac, Mihaela
    SEMINARS IN RADIATION ONCOLOGY, 2019, 29 (03) : 198 - 208
  • [33] To evaluate the absolute dose calculated by CadPlan in an anthropomorphic phantom
    Lo, C
    Huang, D
    Sheu, R
    Chang, B
    Hong, J
    Chen, I
    MEDICAL PHYSICS, 2004, 31 (06) : 1923 - 1923
  • [34] A Novel Multimodal Anthropomorphic Physical Pelvis Phantom for MRI-Based Radiotherapy
    Singhrao, K.
    Fu, J.
    Tenn, S.
    Wu, H.
    Hu, P.
    Cao, M.
    Kishan, A.
    Chin, R.
    Lewis, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E256 - E256
  • [35] VERIFICATION OF MONTE CARLO DOSE CALCULATIONS IN AN ANTHROPOMORPHIC THORAX PHANTOM FOR CYBERKNIFE TREATMENT OF SMALL LUNG TUMOURS.
    Marijnissen, H.
    Hol, M.
    van der Baan, P.
    Heijmen, B.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S114 - S115
  • [36] Progress Toward the Development of a Deformable Anthropomorphic 3D Dosimetric Phantom
    Juang, T.
    Das, S.
    Adamovics, J.
    Oldham, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Dose - Position Verification of 4D Radiotherapy Using the RADPOS System in a Deformable Lung Phantom
    Cherpak, A.
    Serban, M.
    Seuntjens, J.
    Cygler, J.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [38] Technical Note: On the feasibility of performing dosimetry in target and organ at risk using polymer dosimetry gel and thermoluminescence detectors in an anthropomorphic, deformable, and multimodal pelvis phantom
    Marot, Mathieu
    Elter, Alina
    Mann, Philipp
    Schwahofer, Andrea
    Lang, Clemens
    Johnen, Wibke
    Korber, Stefan A.
    Beuthien-Baumann, Bettina
    Gillmann, Clarissa
    MEDICAL PHYSICS, 2021, 48 (09) : 5501 - 5510
  • [39] Verification of a stereotactic treatment plan in an anthropomorphic phantom by means of radiographic films
    Brautmeier, L.
    Hantschick, E.
    Schroeder, A. -K
    Meyer, N.
    Stelljes, T. S.
    Poppe, B.
    Willborn, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S101 - S101
  • [40] EFFECTIVE DOSE MEASUREMENT AT WORKPLACES WITHIN AN INSTRUMENTED ANTHROPOMORPHIC PHANTOM
    Villagrasa, C.
    Darreon, J.
    Martin-Burtat, N.
    Clairand, I.
    Colin, J.
    Fontbonne, J. M.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 640 - 644