The accuracy of ultrasound scan in diagnosing retained products of conception: a systematic review and meta-analysis

被引:3
|
作者
Sundararajan, Srividya [1 ]
Roy, Subhadeep [2 ]
Polanski, Lukasz T. [3 ]
机构
[1] East Suffolk & North Essex NHS Trust, Ipswich Gen Hosp, Dept Obstet & Gynaecol, Ipswich, England
[2] West Suffolk Hosp NHS Trust, Dept Obstet & Gynaecol, Bury St Edmunds, England
[3] North West Anglia NHS Fdn Trust, Peterborough City Hosp, Dept Obstet & Gynaecol, Peterborough, England
关键词
cesarean; Doppler; endometrium; miscarriage; retained products of conception; termination; transvaginal ultrasonography; COLOR DOPPLER; TRANSVAGINAL SONOGRAPHY; SENSITIVITY; MANAGEMENT; PREGNANCY;
D O I
10.1016/j.ajog.2023.11.1243
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: This study aimed to analyze and summarize the evidence on the accuracy of different ultrasound methods in the diagnosis of retained products of conception. DATA SOURCES: We searched Ovid SP, the Cumulative Register to Nursing & Allied Health Literature, EBSCO, and grey literature including STUDY ELIGIBILITY CRITERIA: We included prospective and retrospective cross-sectional or Cohort studies that evaluated both ultrasound findings (before management of retained products of conception) and histopathologic results of retained products of conception at all gestational ages. METHODS: We used Covidence for data extraction from the studies and quality assessment. The meta-analysis was performed using RevMan 5.4 (forest plot), MetaDTA version 2.01, and Meta-DiSc 2.0 online software. RESULTS: In total, 11 studies were eligible for data extraction and meta-analysis. The total number of study participants from these 11 studies were 1567. Of these, 9 studies were included to test the accuracy of an echogenic mass, 4 studies analyzed the accuracy of endometrial thickness, and 5 studies analyzed the accuracy of color Doppler flow to predict retained products of conception. We found that echogenic mass had the highest sensitivity, specificity, and diagnostic odds ratio for predicting retained products of conception. The sensitivity, specificity, and diagnostic odds ratio were 0.915 (95% confidence interval, 0.844-0.955), 0.843 (95% confidence interval, 0.615-0.947), and 57.787 (95% confidence interval, 15.171-220.112), respectively. The diagnostic threshold for endometrial thickness was set at 10 mm with a sensitivity, specificity, and diagnostic odds ratio of 0.667 (95% confidence interval, 0.072-0.981), 0.866 (95% confidence interval, 0.375-0.986), and 12.927 (95% confidence interval, 0.23-726.582). The sensitivity, specificity, and diagnostic odds ratio of color Doppler flow were 0.850 (95% confidence interval, 0.756-0.913), 0.406 (95% confidence interval, 0.198-0.655), and 3.893 (95% confidence interval, 1.005-15.081). CONCLUSION: Our review concluded that an echogenic mass is the most sensitive and specific predictor of retained products of conception after any pregnancy event. The most important limitation of our review is that the design of the studies included led to significant statistical heterogeneity.
引用
收藏
页码:512 / 531.e3
页数:23
相关论文
共 50 条
  • [41] Recommendations for diagnosing STIC: a systematic review and meta-analysis
    Joep M. A. Bogaerts
    Miranda P. Steenbeek
    Majke H. D. van Bommel
    Johan Bulten
    Jeroen A. W. M. van der Laak
    Joanne A. de Hullu
    Michiel Simons
    Virchows Archiv, 2022, 480 : 725 - 737
  • [42] Recommendations for diagnosing STIC: a systematic review and meta-analysis
    Bogaerts, Joep M. A.
    Steenbeek, Miranda P.
    van Bommel, Majke H. D.
    Bulten, Johan
    van der Laak, Jeroen A. W. M.
    de Hullu, Joanne A.
    Simons, Michiel
    VIRCHOWS ARCHIV, 2022, 480 (04) : 725 - 737
  • [43] SONAR IN PUERPERIUM - MEANS OF DIAGNOSING RETAINED PRODUCTS OF CONCEPTION
    ROBINSON, HP
    SCOTTISH MEDICAL JOURNAL, 1972, 17 (11) : 364 - +
  • [44] Accuracy of multiparametric magnetic resonance imaging for diagnosing prostate Cancer: a systematic review and meta-analysis
    Liang Zhen
    Xiaoqiang Liu
    Chen Yegang
    Yang Yongjiao
    Xu Yawei
    Kang Jiaqi
    Wang Xianhao
    Song Yuxuan
    Hu Rui
    Zhang Wei
    Ou Ningjing
    BMC CANCER, 2019, 19 (01)
  • [45] Accuracy of Point-of-care Ultrasonography for Diagnosing Acute Appendicitis: A Systematic Review and Meta-analysis
    Fields, J. Matthew
    Davis, Joshua
    Alsup, Carl
    Bates, Amanda
    Au, Arthur
    Adhikari, Srikar
    Farrell, Isaac
    ACADEMIC EMERGENCY MEDICINE, 2017, 24 (09) : 1124 - 1136
  • [46] Appraising the Accuracy of Ischaemia-Modified Albumin in Diagnosing Stroke: A Systematic Review and Meta-Analysis
    Shi, Wenhua
    Tang, Guanghua
    Zhou, Xianshi
    Ye, Ye
    CEREBROVASCULAR DISEASES, 2021, 50 (04) : 365 - 370
  • [47] Accuracy of multiparametric magnetic resonance imaging for diagnosing prostate Cancer: a systematic review and meta-analysis
    Liang Zhen
    Xiaoqiang Liu
    Chen Yegang
    Yang Yongjiao
    Xu Yawei
    Kang Jiaqi
    Wang Xianhao
    Song Yuxuan
    Hu Rui
    Zhang Wei
    Ou Ningjing
    BMC Cancer, 19
  • [48] DIAGNOSTIC ACCURACY OF POINT OF CARE TESTS FOR DIAGNOSING CELIAC DISEASE: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Singh, Prashant
    Arora, Ananya
    Strand, Tor A.
    Leffler, Daniel A.
    Maki, Markku
    Kelly, Ciaran P.
    Ahuja, Vineet
    Makharia, Govind K.
    GASTROENTEROLOGY, 2018, 154 (06) : S674 - S674
  • [49] Diagnostic Accuracy of Point of Care Tests for Diagnosing Celiac Disease A Systematic Review and Meta-Analysis
    Singh, Prashant
    Arora, Ananya
    Strand, Tor A.
    Leffler, Daniel A.
    Maki, Markku
    Kelly, Ciaran P.
    Ahuja, Vineet
    Makharia, Govind K.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2019, 53 (07) : 535 - 542
  • [50] Accuracy of machine learning in diagnosing microsatellite instability in gastric cancer: A systematic review and meta-analysis
    Ying, Yuou
    Ju, Ruyi
    Wang, Jieyi
    Li, Wenkai
    Ji, Yuan
    Shi, Zhenyu
    Chen, Jinhan
    Chen, Mingxian
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2025, 193