The accuracy of ultrasound scan in diagnosing retained products of conception: a systematic review and meta-analysis

被引:3
|
作者
Sundararajan, Srividya [1 ]
Roy, Subhadeep [2 ]
Polanski, Lukasz T. [3 ]
机构
[1] East Suffolk & North Essex NHS Trust, Ipswich Gen Hosp, Dept Obstet & Gynaecol, Ipswich, England
[2] West Suffolk Hosp NHS Trust, Dept Obstet & Gynaecol, Bury St Edmunds, England
[3] North West Anglia NHS Fdn Trust, Peterborough City Hosp, Dept Obstet & Gynaecol, Peterborough, England
关键词
cesarean; Doppler; endometrium; miscarriage; retained products of conception; termination; transvaginal ultrasonography; COLOR DOPPLER; TRANSVAGINAL SONOGRAPHY; SENSITIVITY; MANAGEMENT; PREGNANCY;
D O I
10.1016/j.ajog.2023.11.1243
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: This study aimed to analyze and summarize the evidence on the accuracy of different ultrasound methods in the diagnosis of retained products of conception. DATA SOURCES: We searched Ovid SP, the Cumulative Register to Nursing & Allied Health Literature, EBSCO, and grey literature including STUDY ELIGIBILITY CRITERIA: We included prospective and retrospective cross-sectional or Cohort studies that evaluated both ultrasound findings (before management of retained products of conception) and histopathologic results of retained products of conception at all gestational ages. METHODS: We used Covidence for data extraction from the studies and quality assessment. The meta-analysis was performed using RevMan 5.4 (forest plot), MetaDTA version 2.01, and Meta-DiSc 2.0 online software. RESULTS: In total, 11 studies were eligible for data extraction and meta-analysis. The total number of study participants from these 11 studies were 1567. Of these, 9 studies were included to test the accuracy of an echogenic mass, 4 studies analyzed the accuracy of endometrial thickness, and 5 studies analyzed the accuracy of color Doppler flow to predict retained products of conception. We found that echogenic mass had the highest sensitivity, specificity, and diagnostic odds ratio for predicting retained products of conception. The sensitivity, specificity, and diagnostic odds ratio were 0.915 (95% confidence interval, 0.844-0.955), 0.843 (95% confidence interval, 0.615-0.947), and 57.787 (95% confidence interval, 15.171-220.112), respectively. The diagnostic threshold for endometrial thickness was set at 10 mm with a sensitivity, specificity, and diagnostic odds ratio of 0.667 (95% confidence interval, 0.072-0.981), 0.866 (95% confidence interval, 0.375-0.986), and 12.927 (95% confidence interval, 0.23-726.582). The sensitivity, specificity, and diagnostic odds ratio of color Doppler flow were 0.850 (95% confidence interval, 0.756-0.913), 0.406 (95% confidence interval, 0.198-0.655), and 3.893 (95% confidence interval, 1.005-15.081). CONCLUSION: Our review concluded that an echogenic mass is the most sensitive and specific predictor of retained products of conception after any pregnancy event. The most important limitation of our review is that the design of the studies included led to significant statistical heterogeneity.
引用
收藏
页码:512 / 531.e3
页数:23
相关论文
共 50 条
  • [31] Ultrasound for the diagnosis of testicular torsion: a systematic review and meta-analysis of diagnostic accuracy
    Alexander, C. E.
    Light, A.
    Chan, V
    Asif, A.
    Clement, K.
    Warren, H.
    Zimmermann, E.
    Khadouri, S.
    Eyskens, P.
    Takwoingi, Y.
    Sidhu, P.
    Shah, T.
    Kasivisvanathan, V
    EUROPEAN UROLOGY, 2024, 85 : S41 - S41
  • [32] Staging accuracy of esophageal cancer by endoscopic ultrasound:A meta-analysis and systematic review
    Srinivas R Puli
    Jyotsna BK Reddy
    Matthew L Bechtold
    Daphne Antillon
    Jamal A Ibdah
    Mainor R Antillon
    World Journal of Gastroenterology, 2008, (10) : 1479 - 1490
  • [33] Staging accuracy of ampullary tumors by endoscopic ultrasound: Meta-analysis and systematic review
    Trikudanathan, Guru
    Njei, Basile
    Attam, Rajeev
    Arain, Mustafa
    Shaukat, Aasma
    DIGESTIVE ENDOSCOPY, 2014, 26 (05) : 617 - 626
  • [34] Accuracy of duplex ultrasound in peripheral artery disease: a systematic review and meta-analysis
    Dias, Silfayner Victor Mathias
    Flumignan, Ronald Luiz Gomes
    Junior, Nelson Carvas
    Iared, Wagner
    JORNAL VASCULAR BRASILEIRO, 2025, 24
  • [35] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 (07) : 1269 - 1278
  • [36] Diagnostic accuracy of cardiopulmonary ultrasound for pulmonary embolism: A systematic review and meta-analysis
    Cao, Jingli
    Sun, Junjie
    Wang, Yuanyuan
    Wang, Lihong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (02): : 185 - 193
  • [37] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 601 - 601
  • [38] Diagnostic accuracy of ultrasound for small bowel obstruction: A systematic review and meta-analysis
    Lin, You-Cheng
    Yu, Yi-Chung
    Huang, Yu-Ting
    Wu, Yun-Yu
    Wang, Ting-Cheng
    Huang, Wen-Cheng
    Yang, Meng-Duo
    Hsu, Yuan-Pin
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [39] Diagnostic test accuracy of ultrasound for sarcopenia diagnosis: A systematic review and meta-analysis
    Fu, Hongbo
    Wang, Lei
    Zhang, Wenyi
    Lu, Jing
    Yang, Ming
    JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2023, 14 : 57 - 70
  • [40] Diagnostic Accuracy of Ultrasonography in Retained Soft Tissue Foreign Bodies: A Systematic Review and Meta-analysis
    Davis, Joshua
    Czerniski, Byron
    Au, Arthur
    Adhikari, Srikar
    Farrell, Isaac
    Fields, J. Matthew
    ACADEMIC EMERGENCY MEDICINE, 2015, 22 (07) : 777 - 787