Uranium isotopic analysis in unpurified solutions by ICP-MS

被引:5
|
作者
Scott, Sean R. [1 ]
Hobbs, Kirby P. [1 ]
French, Amanda D. [1 ]
Arnquist, Isaac J. [1 ]
Anguiano, Sonia Alcantar [1 ]
Sullivan, Daniel L. [1 ]
Herman, Staci M. [1 ]
机构
[1] Pacific Northwest Natl Lab, Richland, WA 99354 USA
关键词
RATIO MEASUREMENTS; U-ISOTOPE; ENVIRONMENTAL-SAMPLES; BIOLOGICAL SAMPLES; PLUTONIUM; PRECONCENTRATION; OPTIMIZATION; SEPARATION; PRECISE; THORIUM;
D O I
10.1039/d4ja00130c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass spectrometry is a widely used tool for analysis of uranium isotopic composition. For solution based inductively coupled plasma mass spectrometry, uranium isotopes are typically analyzed after purification from complex matrices. In this work, we tested the ability of three mass spectrometers (ThermoScientific iCAP TQ, ThermoScientific Neoma, and Agilent 8900) to analyze uranium isotopes in an unpurified NIST reference material (SRM2780a, Hard Rock Mine Waste) digest solution. Results indicate that 235U/238U can be analyzed within 1% of the true value. 234U/238U is a more challenging analysis due to low count rates and potential isobar interferences, but strategies to mitigate these effects, such as the use of reaction gases in a collision cell and desolvating nebulizer introduction system, are effective for the triple quadrupole instruments. However, the use of the Neoma MS/MS in reaction mode using O2 gas was problematic. Nevertheless, analysis of unpurified solutions for quick assessment of uranium isotope compositions is practical, especially when high precision is not required. Uranium isotope analysis in unpurified samples using ICP-MS provides accurate results across platforms.
引用
收藏
页码:2106 / 2115
页数:10
相关论文
共 50 条
  • [41] Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS
    Manard, Benjamin T.
    Rogers, Kayron T.
    Ticknor, Brian W.
    Metzger, Shalina C.
    Zirakparvar, N. Alex
    Roach, Benjamin D.
    Bostick, Debra A.
    Hexel, Cole R.
    ANALYTICAL CHEMISTRY, 2021, 93 (32) : 11133 - 11139
  • [42] INTERFERENCE EFFECTS AND THEIR CONTROL IN ICP-MS ANALYSIS OF SERUM AND SALINE SOLUTIONS
    GEROTTO, M
    DELLANDREA, E
    BORTOLI, A
    MARCHIORI, M
    PALONTA, M
    TRONCON, A
    MICROCHEMICAL JOURNAL, 1995, 51 (1-2) : 73 - 87
  • [43] Determination of U isotopic ratios in environmental samples by ICP-MS
    Uchida, S
    García-Tenorio, R
    Tagami, K
    García-León, M
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (07) : 889 - 892
  • [44] ICP-MS
    不详
    MICRO, 1995, 13 (02): : 44 - 44
  • [45] Matrix-induced isotopic mass fractionation in the ICP-MS
    Carlson, RW
    Hauri, EH
    Alexander, CMO
    PLASMA SOURCE MASS SPECTROMETRY: THE NEW MILLENNIUM, 2001, (267): : 288 - 297
  • [46] FROM LITHIUM TO URANIUM, PICOGRAMS TO PERCENT - THE VERSATILITY OF ICP-MS
    MCLAREN, JW
    BEAUCHEMIN, D
    BERMAN, SS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 125 - ANYL
  • [47] Uranium isotopic ratio determination in urine using flow-injection ICP-MS: a tool for emergency monitoring
    Godoy, Maria Luiza D. P.
    Juliao, Ligia M. Q. C.
    Godoy, Jose Marcus
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 234 - 239
  • [48] DETERMINATION OF ULTRATRACE AMOUNTS OF URANIUM AND THORIUM IN MOLYBDENUM BY ICP-MS
    KAWAMURA, T
    BUNSEKI KAGAKU, 1988, 37 (11) : 585 - 588
  • [49] ICP-MS
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1986, 5 (08) : R8 - R8
  • [50] ICP-MS measurement of uranium and thorium contents in minerals in China
    Liang-Liang Yin
    Qing Tian
    Xian-Zhang Shao
    Bao-Ming Shen
    Xu Su
    Yan-Qin Ji