Uranium isotopic analysis in unpurified solutions by ICP-MS

被引:5
|
作者
Scott, Sean R. [1 ]
Hobbs, Kirby P. [1 ]
French, Amanda D. [1 ]
Arnquist, Isaac J. [1 ]
Anguiano, Sonia Alcantar [1 ]
Sullivan, Daniel L. [1 ]
Herman, Staci M. [1 ]
机构
[1] Pacific Northwest Natl Lab, Richland, WA 99354 USA
关键词
RATIO MEASUREMENTS; U-ISOTOPE; ENVIRONMENTAL-SAMPLES; BIOLOGICAL SAMPLES; PLUTONIUM; PRECONCENTRATION; OPTIMIZATION; SEPARATION; PRECISE; THORIUM;
D O I
10.1039/d4ja00130c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass spectrometry is a widely used tool for analysis of uranium isotopic composition. For solution based inductively coupled plasma mass spectrometry, uranium isotopes are typically analyzed after purification from complex matrices. In this work, we tested the ability of three mass spectrometers (ThermoScientific iCAP TQ, ThermoScientific Neoma, and Agilent 8900) to analyze uranium isotopes in an unpurified NIST reference material (SRM2780a, Hard Rock Mine Waste) digest solution. Results indicate that 235U/238U can be analyzed within 1% of the true value. 234U/238U is a more challenging analysis due to low count rates and potential isobar interferences, but strategies to mitigate these effects, such as the use of reaction gases in a collision cell and desolvating nebulizer introduction system, are effective for the triple quadrupole instruments. However, the use of the Neoma MS/MS in reaction mode using O2 gas was problematic. Nevertheless, analysis of unpurified solutions for quick assessment of uranium isotope compositions is practical, especially when high precision is not required. Uranium isotope analysis in unpurified samples using ICP-MS provides accurate results across platforms.
引用
收藏
页码:2106 / 2115
页数:10
相关论文
共 50 条
  • [21] Procedure for direct determination of uranium in urine by ICP-MS
    Ritt, J.
    Cossonnet, C.
    Radioprotection, 2001, 36 (02) : 167 - 181
  • [22] Feasibility of ICP-MS for the assessment of uranium excretion in urine
    E. Werner
    P. Roth
    I. Wendler
    P. Schramel
    H. Hellmann
    U. Kratzel
    Journal of Radioanalytical and Nuclear Chemistry, 1997, 226 : 201 - 203
  • [23] LEAD IN ARCHAEOLOGICAL SAMPLES - AN ISOTOPIC STUDY BY ICP-MS
    GHAZI, AM
    APPLIED GEOCHEMISTRY, 1994, 9 (06) : 627 - 636
  • [24] Chemical metrology employing isotopic dilution and ICP-MS
    Stumpf, C
    Labarraque, G
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2003, 48 (06): : 343 - 351
  • [25] Analysis of Wastewater by ICP-MS
    P. V. Yakimovich
    A. V. Alekseev
    Metallurgist, 2018, 62 : 3 - 9
  • [26] Method for the Determination of Thorium and Uranium in Urine by ICP-MS
    Schramel, P.
    Wendler, I.
    Roth, P.
    Werner, E.
    Mikrochimica Acta, 126 (3-4):
  • [27] ICP-MS: A tool for monitoring the internal contaminations in uranium
    Frelon, S.
    Monleau, M.
    Tourlonias, E.
    Delissen, O.
    Chazel, V.
    Paquet, F.
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2005, 50 (05): : 280 - 288
  • [28] Method for the determination of thorium and uranium in urine by ICP-MS
    Schramel, P
    Wendler, I
    Roth, P
    Werner, E
    MIKROCHIMICA ACTA, 1997, 126 (3-4) : 263 - 266
  • [29] DETERMINATION OF ULTRATRACE URANIUM AND THORIUM IN GOLD BY ICP-MS
    ITO, K
    KUBOYAMA, S
    OGURO, H
    KAGAYA, T
    SHIMAMURA, T
    BUNSEKI KAGAKU, 1988, 37 (01) : 25 - 29
  • [30] Determination of uranium, thorium and plutonium isotopes by ICP-MS
    Shi, Y.
    Collins, R.
    Broome, C.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (01) : 509 - 515