Design optimization of the cooling systems with PCM-to-air heat exchanger for the energy saving of the residential buildings

被引:4
|
作者
Zhang, Qian [1 ]
Sazon, Thor Alexis Salazar [1 ]
Fadnes, Fredrik Skaug [1 ,2 ]
Peng, Xianyong [3 ]
Ahmed, Naveed [1 ,4 ]
Nikpey, Homam [1 ]
Mansouri, Mohammad [1 ]
Assadi, Mohsen [1 ]
机构
[1] Univ Stavanger, Dept Energy & Petr Engn, Stavanger, Norway
[2] Norconsult AS, Oslo, Norway
[3] China Univ Min & Technol, Sch Low Carbon Energy & Power Engn, Xuzhou, Peoples R China
[4] Natl Univ Sci & Technol NUST, US Pakistan Ctr Adv Studies Energy USPCASE, H-12 Sect, Islamabad, Pakistan
关键词
Space cooling; Phase change material; Design optimization; Artificial neural network; PHASE-CHANGE MATERIALS; ECONOMIC-ANALYSIS; STORAGE TANK; PERFORMANCE ANALYSIS; THERMAL PERFORMANCE; NEURAL-NETWORKS; PUMP SYSTEM; SIMULATION; PARAMETERS; MODEL;
D O I
10.1016/j.ecmx.2024.100630
中图分类号
O414.1 [热力学];
学科分类号
摘要
Driven by a rapid surge in cooling demand in buildings, the energy consumption dedicated to cooling has experienced remarkable growth. To address this challenge, the adoption of latent heat thermal energy storage utilizing phase change materials (PCM) has gained significant momentum in recent years. This paper presents the design and evaluation of an integrated latent heat thermal energy storage (ILHTES) system tailored for residential buildings. This system integrates a PCM-to-air heat exchanger (PAHX) with an air conditioning unit. Modelica language is utilized to develop a numerical model for the ILHTES system. The heat transfer model of the PAHX is developed and validated using existing literature data. To simulate the dynamic behavior and energy consumption of the residential building, the open -source library AixLib is adopted. The developed ILHTES system model is used for the optimization of key design variables, including the PCM slab thickness and air flow rate, based on the results of long-term simulations covering the entire cooling season. Evaluation of the energy saving potential of the optimized ILHTES systems is carried out in comparison to conventional air conditioning systems, considering various climatic conditions in five European cities. The results highlight the profound impact of PCM types on the Energy Saving Ratio (ESR) throughout the entire cooling season. Among the four commercially available PCMs examined - RT27, RT25, RT20, and RT18 - RT25 consistently outperforms the others. Across all five cities investigated, using RT25 leads to a minimum ESR of 16% in Catania and a maximum ESR of 44.7% in Stockholm for the entire cooling season.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Performance analysis of a dual-stack Air-PCM heat exchanger with novel air flow configuration for cooling applications in buildings
    Dallaire, Jonathan
    Hassan, Hafiz Muhammad Adeel
    Bjernemose, Jesper Holm
    Hansen, Mads Peter Rudolph
    Lund, Ivar
    Veje, Christian T.
    BUILDING AND ENVIRONMENT, 2022, 223
  • [22] Opportunities and challenges of PCM-to-air heat exchangers (PAHXs) for building free cooling applications-A comprehensive review
    Dardir, Mohamed
    Panchabikesan, Karthik
    Haghighat, Fariborz
    El Mankibi, Mohamed
    Yuan, Yanping
    JOURNAL OF ENERGY STORAGE, 2019, 22 : 157 - 175
  • [23] Experimental analysis of air-multiple pcm heat exchanger in evaporative cooling systems for supply air temperature stabilization
    Kareem, Bashir Eskander
    Adham, Ahmed Mohammed
    Yaqob, Banipal Nanno
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [24] Solar chimney combined with earth to-air heat exchanger for passive cooling of residential buildings in hot areas
    Serageldin, Ahmed A.
    Abdeen, Ahmed
    Ahmed, Mostafa M. S.
    Radwan, Ali
    Shmroukh, Ahmed N.
    Ookawara, Shinichi
    SOLAR ENERGY, 2020, 206 (206) : 145 - 162
  • [25] Energy saving of residential buildings using simultaneous application of DSF, PCM, and PV cells
    Pouran, Mahdi
    Fazelpour, Farivar
    Gharehpetian, G. B.
    Saraei, Alireza
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2025, 17 (01)
  • [26] Analysis and design of an air to air heat exchanger used in energy recovery systems
    Elmacioǧlu H.U.
    Özsevgin I.
    Kocabiyik C.
    Čam N.Y.
    Bilir L.
    Journal of Energy Systems, 2022, 6 (01): : 108 - 130
  • [27] ASSESSMENT OF THE COOLING POTENTIAL OF AN EARTH-TUBE HEAT EXCHANGER IN RESIDENTIAL BUILDINGS
    Zukowski, Miroslaw
    Sadowska, Beata
    Sarosiek, Wieslaw
    ENVIRONMENTAL ENGINEERING, VOLS 1-3, 2011, : 830 - +
  • [28] Design Optimization of Energy Flexibility for Residential Buildings
    Mugnini, Alice
    Polonara, Fabio
    Arteconi, Alessia
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 2811 - 2818
  • [29] Energy and economic optimization of solar-assisted heat pump systems with storage technologies for heating and cooling in residential buildings
    Pinamonti, Maria
    Baggio, Paolo
    RENEWABLE ENERGY, 2020, 157 : 90 - 99
  • [30] Design and analysis of PCM based radiant heat exchanger for thermal management of buildings
    Garg, Himanshu
    Pandey, Brijesh
    Saha, Sandip K.
    Singh, Suneet
    Banerjee, Rangan
    ENERGY AND BUILDINGS, 2018, 169 : 84 - 96