Experimental analysis of air-multiple pcm heat exchanger in evaporative cooling systems for supply air temperature stabilization

被引:5
|
作者
Kareem, Bashir Eskander [1 ]
Adham, Ahmed Mohammed [1 ]
Yaqob, Banipal Nanno [1 ]
机构
[1] Erbil Polytech Univ, Erbil Tech Engn Coll, Dept Tech Mech & Energy Engn, Erbil, Iraq
来源
关键词
Air to multiple PCM heat exchanger; Evaporative cooling system; Thermal comfort; PCM-RT21; PCM-RT25; STORAGE; PERFORMANCE; BUILDINGS; DESICCANT; CLIMATE; DRY; HOT;
D O I
10.1016/j.jobe.2023.108269
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The free cooling system is a highly efficient solution that effectively regulates indoor temperature when the ambient air temperature fluctuates within the thermal comfort range. Compared to traditional cooling systems, the evaporative cooling system excels in cost-effectiveness and has exceptional efficiency in hot and dry climates. However, the system's performance is significantly influenced by the environment, leading to fluctuations in the outlet temperatures of the evaporative cooler. A novel approach to integrating thermal energy storage with an evaporative cooling system has been studied to achieve free cooling and stabilize the system's supply air temperature to address this challenge. The evaporative cooler's design, construction, and experimental testing have been carried out in highly challenging hot and dry environments. The utilization of phase change materials (RT21HC and RT25HC) as a thermal energy storage system has been implemented. Incorporating phase change materials has notably improved the stability of the outlet air temperature from the evaporative cooling system. Furthermore, the outlet air temperature from the system exhibited consistent fluctuations within the range of 21-25 degrees C, requiring a significant amount of energy absorption and release to exceed these temperature thresholds. The findings demonstrate that the proposed system effectively reduces and shifts peak load to off-peak hours. Moreover, thermal energy storage can deliver free cooling during the spring and autumn. However, integrating the PAHX into an evaporative cooling system becomes crucial in regions characterized by extremely hot summer seasons. The maximum deviation between numerical and experimental results is 4 %.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Universal heat exchanger for air and evaporative cooling of electronics
    Doubek, Martin
    Vacek, Vaclav
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 23
  • [2] Experimental performance and parametric analysis of heat pipe heat exchanger for air conditioning application integrated with evaporative cooling
    Tushar S. Jadhav
    Mandar M. Lele
    Heat and Mass Transfer, 2017, 53 : 3287 - 3293
  • [3] Experimental performance and parametric analysis of heat pipe heat exchanger for air conditioning application integrated with evaporative cooling
    Jadhav, Tushar S.
    Lele, Mandar M.
    HEAT AND MASS TRANSFER, 2017, 53 (11) : 3287 - 3293
  • [4] Experimental and numerical investigation of a real-scale air to multiple PCM heat exchanger
    Kareem, Bashir Eskander
    Adham, Ahmed Mohammed
    Yaqob, Banipal Nanno
    JOURNAL OF BUILDING ENGINEERING, 2024, 89
  • [5] Numerical modeling and experimental validation of a PCM to air heat exchanger
    Lopez, Juan Pablo Arzamendia
    Kuznik, Frederic
    Baillis, Dominique
    Virgone, Joseph
    ENERGY AND BUILDINGS, 2013, 64 : 415 - 422
  • [6] Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
    Lu, Shilei
    Liang, Bin
    Li, Xinhua
    Kong, Xiangfei
    Jia, Wei
    Wang, Lu
    MATERIALS, 2020, 13 (13) : 1 - 17
  • [7] Experimental investigation of a solar PCM heat exchanger for indoor temperature stabilization
    Zaib, Aurang
    Mazhar, Abdur Rehman
    Talha, Tariq
    Inshal, Muhammad
    ENERGY AND BUILDINGS, 2023, 297
  • [8] Performance enhancement of earth air tunnel heat exchanger using evaporative cooling
    Bansal, Vikas
    Mathur, Jyotirmay
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2009, 4 (03) : 150 - 158
  • [9] Techno-Economic Assessment of an Air-Multiple PCM Active Storage Unit for Free Cooling Application
    Iten, Muriel
    SUSTAINABILITY, 2021, 13 (23)
  • [10] Design optimization of the cooling systems with PCM-to-air heat exchanger for the energy saving of the residential buildings
    Zhang, Qian
    Sazon, Thor Alexis Salazar
    Fadnes, Fredrik Skaug
    Peng, Xianyong
    Ahmed, Naveed
    Nikpey, Homam
    Mansouri, Mohammad
    Assadi, Mohsen
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 23