Shaking table test of a dry-connection fully precast frame structure system

被引:1
|
作者
Zhang, Ruijun [1 ,2 ]
Guo, Tong [1 ,4 ]
Wu, Yifeng [2 ]
Li, Aiqun [1 ,2 ]
Zhu, Ruizhao [1 ]
Yang, T. Y. [3 ]
机构
[1] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Multifunct Shaking Tables Lab, Beijing, Peoples R China
[3] Univ British Columbia, Dept Civil Engn, Vancouver, BC, Canada
[4] Southeast Univ, Sch Civil Engn, Nanjing 211189, Peoples R China
来源
关键词
Dry connection; Precast concrete; Frame structure; Shaking table test; Seismic performance;
D O I
10.1016/j.jobe.2024.109134
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In view of the construction difficulties and ecological environment sensitivity of building construction in extremely cold and high seismic intensity areas, a new type of dry-connection fully precast frame structure system was proposed. The connections of the structure are easy to assemble, which can greatly improve the construction efficiency and provide convenience for the upgrading and replacement of components during service. In order to provide essential insights into the seismic performance of the dry-connection precast structure, a three-story precast frame structure specimen with a scale ratio of 1/2 was designed, constructed, and tested on a shaking table subjected to a series of ground motions with increasing seismic intensities. The connections of the specimen structure include beam-column joint, beam-floor joint and column-foundation joint, precast components were processed in the factory and assembled in the laboratory. The vibration characteristics, damage development, acceleration response and displacement response of the structure were investigated. The experimental results illustrated the excellent seismic performance of the structure with sufficient strength and relatively confined damage. The gradually decreasing frequency and increasing damping ratio were attributed to the slippage and plastic deformation of the connectors and the cracking of beam concrete. And the maximum story drift under rare earthquake of intensity 8 was within the design limit, indicated that the precast frame structure could achieve the performance target of no collapse under severe earthquakes. The data of this test provided support for further study on the design methods and numerical modeling of dry-connection fully precast frame structure systems.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Development of fully dry-connection for prefabricated hollow section CA-RPC pier
    Cui, Bing
    Zhu, Shengchun
    Zhang, Guangda
    Tan, Shun
    Zhao, Canhui
    Deng, Kailai
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 19
  • [32] Shaking table test on a precast concrete shear wall structure with discontinuous vertical distributing reinforcements
    Cai Q.
    Song X.
    Xiao X.
    Gu X.
    Zhang S.
    Liao X.
    Su Q.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (07): : 91 - 99
  • [33] Shaking table test on hybrid structure with SRC frame and steel frame strengthened concrete core tube
    Du W.
    Zhang L.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2016, 37 (07): : 127 - 135
  • [34] Shaking table test of viscoelastic structure
    2001, Science Press (22):
  • [35] Shaking table comparative test and associated study of a stepped wall-frame structure
    Weixiao Xu
    Jingjiang Sun
    Weisong Yang
    Ke Du
    Earthquake Engineering and Engineering Vibration, 2014, 13 : 471 - 485
  • [36] Shaking table comparative test and associated study of a stepped wall-frame structure
    Xu Weixiao
    Sun Jingjiang
    Yang Weisong
    Du Ke
    Earthquake Engineering and Engineering Vibration, 2014, 13 (03) : 471 - 485
  • [37] Shaking table comparative test and associated study of a stepped wall-frame structure
    Xu Weixiao
    Sun Jingjiang
    Yang Weisong
    Du Ke
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2014, 13 (03) : 471 - 485
  • [38] Study on shaking table test of steel frame structure with enhanced particle inerter device
    Lu Z.
    Zhou C.
    Yan D.
    Zhang R.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 48 - 55
  • [39] Shaking table test of a steel frame structure with layered three-dimensional isolation
    Shi, Yundong
    Wang, Yuchen
    Wang, Qi
    Dong, Wenqing
    Zhao, Bo
    Ding, Yang
    Li, Zhong-Xian
    Wu, Yitao
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2025, 54 (02): : 583 - 603
  • [40] Shaking table test on isolated step-terrace frame structure in mountainous area
    Zhang L.
    Tao Z.
    Pan W.
    Wu Z.
    Lan X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (09): : 24 - 32and44