Shaking table test of a dry-connection fully precast frame structure system

被引:1
|
作者
Zhang, Ruijun [1 ,2 ]
Guo, Tong [1 ,4 ]
Wu, Yifeng [2 ]
Li, Aiqun [1 ,2 ]
Zhu, Ruizhao [1 ]
Yang, T. Y. [3 ]
机构
[1] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Multifunct Shaking Tables Lab, Beijing, Peoples R China
[3] Univ British Columbia, Dept Civil Engn, Vancouver, BC, Canada
[4] Southeast Univ, Sch Civil Engn, Nanjing 211189, Peoples R China
来源
关键词
Dry connection; Precast concrete; Frame structure; Shaking table test; Seismic performance;
D O I
10.1016/j.jobe.2024.109134
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In view of the construction difficulties and ecological environment sensitivity of building construction in extremely cold and high seismic intensity areas, a new type of dry-connection fully precast frame structure system was proposed. The connections of the structure are easy to assemble, which can greatly improve the construction efficiency and provide convenience for the upgrading and replacement of components during service. In order to provide essential insights into the seismic performance of the dry-connection precast structure, a three-story precast frame structure specimen with a scale ratio of 1/2 was designed, constructed, and tested on a shaking table subjected to a series of ground motions with increasing seismic intensities. The connections of the specimen structure include beam-column joint, beam-floor joint and column-foundation joint, precast components were processed in the factory and assembled in the laboratory. The vibration characteristics, damage development, acceleration response and displacement response of the structure were investigated. The experimental results illustrated the excellent seismic performance of the structure with sufficient strength and relatively confined damage. The gradually decreasing frequency and increasing damping ratio were attributed to the slippage and plastic deformation of the connectors and the cracking of beam concrete. And the maximum story drift under rare earthquake of intensity 8 was within the design limit, indicated that the precast frame structure could achieve the performance target of no collapse under severe earthquakes. The data of this test provided support for further study on the design methods and numerical modeling of dry-connection fully precast frame structure systems.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Shaking table test study on seismic performance of RC frame structure with NES
    Yang, Haixu
    Li, Zhuo
    Wang, Haibiao
    Zhang, Maohua
    Ni, Songyuan
    STRUCTURES, 2023, 47 : 153 - 164
  • [22] A model shaking table test of concrete filled steel tubular frame structure
    Du, Guofeng
    Xu, Lihua
    Chi, Yin
    Song, Zhibin
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 1065 - 1070
  • [23] Research on shaking table test of frame structure crossing the ground fissure with braces
    Xiong Z.-M.
    Chen X.
    Wang Y.
    Xiong W.-Y.
    Zhang C.
    Gongcheng Lixue/Engineering Mechanics, 2019, 36 (10): : 86 - 95
  • [24] Shaking table test of steel frame structure with particle tuned mass damper
    Lu Z.
    Zhang D.
    Lu X.
    1600, Science Press (38): : 10 - 17
  • [25] Shaking Table Test of a Full-Scale RC Frame Structure with an Indoor Gas Piping System
    Sun, Dezhang
    Guo, Endong
    Wu, Houli
    Liu, Zhibin
    Mao, Chenxi
    Zhang, Haoyu
    Sun, Xun
    ADVANCES IN CIVIL ENGINEERING, 2022, 2022
  • [26] Shaking table test on prefabricated steel frame structure with ribbed thin walls
    Zhang Z.
    Cao W.
    Wang R.
    Hou J.
    Chen Y.
    Li D.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2020, 52 (10): : 10 - 18
  • [27] Shaking Table Test of the External Shear Wall and Internal Frame RC Structure
    Gong Y.
    Wang B.
    Gan T.
    Zhou Q.
    Jiang L.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2023, 56 (03): : 301 - 310
  • [28] Shaking table test on a novel mega-frame suspended structural system
    Du, Linpu
    Zhang, Wei
    Tu, Yongming
    Song, Shoutan
    Sas, Gabriel
    Elfgren, Lennart
    JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [29] A MODEL SHAKING TABLE TEST INVESTIGATION ON AN ASSEMBLY FRAME
    Duan, Shujin
    Wang, Zhenlu
    Yu, Yan
    Hua, Qian
    SUSTAINABLE SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2014, : 133 - 138
  • [30] Shaking table test of scaled model of Protiron dry stone masonry structure
    Nikolic, Zeljana
    Krstevska, Lidija
    Marovic, Pavao
    Smoljanovic, Hrvoje
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 3386 - 3391