In Vivo visualization of white matter fiber tracts in the brainstem using low flip angle double echo 3D gradient echo imaging at 3T

被引:1
|
作者
Xu, Qiuyun [1 ]
Chen, Yongsheng [2 ]
Miller, Stephan [3 ]
Bajaj, Kunal [3 ]
Santana, Jairo [3 ]
Badawy, Mohamed [3 ]
Lyu, Haiying [4 ]
Liu, Yu [4 ]
He, Naying [4 ]
Yan, Fuhua [4 ]
Haacke, E. Mark [1 ,2 ,4 ,5 ]
机构
[1] Wayne State Univ, Detroit Receiving Hosp 3L 8, Dept Radiol, 3990 John R,4201 St Antoine, Detroit, MI 48201 USA
[2] Wayne State Univ, Dept Neurol, Detroit Med Ctr, Univ Hlth Ctr, 8th Floor,4201 St Antoine, Detroit, MI 48201 USA
[3] Wayne State Univ, Detroit Med Ctr, Sch Med, Dept Radiol, 3901 Beaubien Blvd, Detroit, MI 48201 USA
[4] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, 197 Ruijin Er Rd, Shanghai 200025, Peoples R China
[5] Wayne State Univ, Detroit Receiving Hosp 3L 8, Dept Biomed Engn, 3990 John R,4201 St Antoine, Detroit, MI 48201 USA
关键词
White matter fiber tracts; Brainstem; Proton density weighted imaging; Low flip angle imaging; STAGE imaging; CORTICOSPINAL TRACT; HIGH-RESOLUTION; MRI; TRACTOGRAPHY; T1; STIMULATION; CONTRAST; ANATOMY;
D O I
10.1016/j.neuroimage.2024.120857
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: White matter (WM) fiber tracts in the brainstem communicate with various regions in the cerebrum, cerebellum, and spinal cord. Clinically, small lesions, malformations, or histopathological changes in the brainstem can cause severe neurological disorders. A direct and non-invasive assessment approach could bring valuable information about the intricate anatomical variations of the white matter fiber tracts and nuclei. Although tractography from diffusion tensor imaging has been commonly used to map the WM fiber tracts connectivity, it is difficult to differentiate the complex WM tracts anatomically. Both high field MRI methods and ultrahigh-field MRI methods at 7T and 11.7 T have been used to enhance the contrast of WM fiber tracts. Despite their promising results, it is still challenging to achieve wide clinical adoption at 3T. In this study, we explored a clinically feasible method using a proton density weighted (PDW) 3D gradient echo (GRE) sequence to directly image the WM fiber tracts in the brainstem at 3T in vivo. Methods: We optimized a 3D high resolution, double echo, short TR, PDW GRE sequence on 5 healthy volunteers using a clinical 3T scanner to visualize the complicated anatomy of WM fiber tracts in the brain stem. Tissue properties including T1, proton density and T2* from in vivo quantitative MRI data were used for simulations to determine the optimal flip angle for the sequence. The visualization of multiple WM fiber tracts in the brainstem was assessed qualitatively and quantitatively using relative contrast and contrast-to-noise ratio (CNR). To improve the CNR, the final images were created by averaging over all echoes from two consecutive scans at the optimal flip angle. The results were compared to anatomical atlases and histology sections to identify the major fiber tracts. All the identified major fiber tracts were labeled on axial, sagittal and coronal slices. Results: The WM fiber tracts were found to have distinct hypointense signal throughout the brainstem and most of the major WM fiber tracts, such as the corticospinal tract, medial lemniscus, medial longitudinal fasciculus, and central tegmental tract, in the brainstem up to and including the thalamus were identified in all subjects. Both qualitative and quantitative evaluations showed that the 3. scan offered the best contrast for WM fiber tracts for a TR of 20 ms. The average over the first two echo times and two consecutive 3. scans gave a CNR of 47.8 +/- 6.2 for the pyramidal tracts in particular and CNRs values greater than 6.5 +/- 2.4 for the rest of the fiber tracts.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Multi-Echo-Based Echo-Planar Spectroscopic Imaging Using a 3T MRI Scanner
    Furuyama, Jon K.
    Burns, Brian L.
    Wilson, Neil E.
    Thomas, M. Albert
    MATERIALS, 2011, 4 (10): : 1818 - 1834
  • [22] Effect of intravenous gadoxetate disodium and flip angle on hepatic proton density fat fraction estimation with six-echo, gradient-recalled-echo, magnitude-based MR imaging at 3T
    Park, Charlie C.
    Hamilton, Gavin
    Desai, Ajinkya
    Zand, Kevin A.
    Wolfson, Tanya
    Hooker, Jonathan C.
    Costa, Eduardo
    Heba, Elhamy
    Clark, Lisa
    Gamst, Anthony
    Loomba, Rohit
    Middleton, Michael S.
    Sirlin, Claude B.
    ABDOMINAL RADIOLOGY, 2017, 42 (04) : 1189 - 1198
  • [23] Effect of intravenous gadoxetate disodium and flip angle on hepatic proton density fat fraction estimation with six-echo, gradient-recalled-echo, magnitude-based MR imaging at 3T
    Charlie C. Park
    Gavin Hamilton
    Ajinkya Desai
    Kevin A. Zand
    Tanya Wolfson
    Jonathan C. Hooker
    Eduardo Costa
    Elhamy Heba
    Lisa Clark
    Anthony Gamst
    Rohit Loomba
    Michael S. Middleton
    Claude B. Sirlin
    Abdominal Radiology, 2017, 42 : 1189 - 1198
  • [24] Imaging arterial and venous vessels using Iron Dextran enhanced multi-echo 3D gradient echo MRI at 7T
    Li, Yinghao
    Li, Wei
    Paez, Adrian
    Cao, Di
    Sun, Yuanqi
    Gu, Chunming
    Zhang, Kaihua
    Miao, Xinyuan
    Liu, Peiying
    Li, Wenbo
    Pillai, Jay
    Lu, Hanzhang
    van Zijl, Peter C. M.
    Earley, Christopher
    Li, Xu
    Hua, Jun
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [25] Fast 3D large-angle spin-echo imaging (3D FLASE)
    Ma, JF
    Wehrli, FW
    Song, HK
    MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (06) : 903 - 910
  • [26] Gradient-echo 3D imaging of Rb polarization in fiber-coupled atomic magnetometer
    Savukov, I.
    JOURNAL OF MAGNETIC RESONANCE, 2015, 256 : 9 - 13
  • [27] Knee osteochondral junction imaging using a fast 3D T1-weighted ultrashort echo time cones sequence at 3T
    Cai, Zhenyu
    Wei, Zhao
    Wu, Mei
    Jerban, Saeed
    Jang, Hyungseok
    Li, Shaolin
    Yuan, Xuchun
    Ma, Ya-Jun
    MAGNETIC RESONANCE IMAGING, 2020, 73 : 76 - 83
  • [28] T2-weighted prostate imaging using echo-planar imaging at 3T
    Ragan, D
    Ma, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1911 - 1911
  • [29] Spin-echo and 3D gradient-echo imaging of the knee joint: A clinical and histopathological comparison
    Guckel, C
    Jundt, G
    Schnabel, K
    Gachter, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) : 25 - 33
  • [30] 3D magnetization prepared elliptical centric fast gradient echo Imaging
    Lin, Chen
    Bernstein, Matt A.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 434 - 439