Experimental evaluation of a heat exchanger for different configurations between internal and external flow

被引:0
|
作者
Ramirez-Dolores, C. [1 ]
Andaverde, J. [2 ]
Ordonez-Castillo, L. [3 ]
Wong-Loya, J. [4 ]
机构
[1] Univ Nacl Autonoma Mexico, Posgrad Ingn, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[2] Univ Veracruzana, Fac Ciencias Quim, Coatzacoalcos 96538, Veracruz, Mexico
[3] Univ Nacl Autonoma Mexico, Licenciatura Ingn Energias Renovables, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[4] Univ Nacl Autonoma Mexico, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
关键词
Fluid flow; Air-water heat exchanger; NTU-epsilon; Heat exchanger positions; THERMAL PERFORMANCE; NUMERICAL EVALUATION; AIR-QUALITY; EARTH; COMFORT; DESIGN; ENERGY; GROUNDWATER; BUILDINGS; EQUATION;
D O I
10.1007/s41939-024-00460-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present work, the determination of the thermal effectiveness and temperature of the air at the outlet of a scale prototype of a heat exchanger immersed in flowing water was developed experimentally. This depended on the position of the working fluid (air) and of the heat exchanger positioning configuration. The tested positions were parallel flow, quasi-parallel oblique, counterflow, quasi-counterflow oblique, and crossflow. The temperature of the air at the outlet of the heat exchanger and the thermal effectiveness are essential to determine the most convenient operating position of these systems, especially those related to shallow geothermal energy. The thermohydraulic aspects of the heat exchanger presented were evaluated, by the Number of Transfer Units-Effectiveness (NTU-epsilon) method, under conditions of water flow in a natural channel and air flow induced by a blower, the system was built from commercial copper pipe and temperature sensors were placed in both the exchanger and the water to record temperature changes. The results of this study indicate that when the exchanger is positioned in the oblique quasi-counterflow position and the oblique quasi-parallel position, it exhibits the lowest air outlet temperatures and highest thermal effectiveness, which is relevant for building cooling applications.
引用
收藏
页码:4117 / 4132
页数:16
相关论文
共 50 条
  • [41] DYNAMICS OF A FLOW-FORCED HEAT EXCHANGER - EXPERIMENTAL CONSIDERATIONS
    KAMMAN, DT
    KOPPEL, LB
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1966, 5 (02): : 208 - &
  • [42] Shell and tube heat exchanger with new segmental baffles configurations: A comparative experimental investigation
    El-Said, Emad M. S.
    Abou Al-Sood, M. M.
    APPLIED THERMAL ENGINEERING, 2019, 150 : 803 - 810
  • [43] Flow and Heat transfer Experimental Investigation of Nanofluid in a Double pipe Heat Exchanger
    Ghalib, Lubna
    Rahma, N. M.
    Eweedand, K. M.
    Al-Kamal, A. K.
    INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND SCIENCE, 2018, 454
  • [44] Experimental investigation of the flow distribution inside a tubular heat exchanger
    Faure, Thierry M.
    Lusseyran, Francois
    Gougat, Pierre
    Launay, Francois
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (06): : 1218 - 1227
  • [45] Experimental Comparisons on Heat Transfer Characteristics of CO2 Air Conditioning System with an Internal Heat Exchanger and without an Internal Heat Exchanger Using Minichannel Evaporator
    Tronghieu Nguyen
    Thanhtrung Dang
    Kimhang Vo
    PROCEEDINGS OF 2019 INTERNATIONAL CONFERENCE ON SYSTEM SCIENCE AND ENGINEERING (ICSSE), 2019, : 648 - 652
  • [46] A comparative study of two different configurations for exothermic-endothermic heat exchanger reactor
    Bayat, M.
    Rahimpour, M. R.
    Taheri, M.
    Pashaei, M.
    Sharifzadeh, S.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2012, 52 : 63 - 73
  • [47] Different reactor and heat exchanger configurations for metal hydride hydrogen storage systems - A review
    Shafiee, Shahin
    McCay, Mary Helen
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (22) : 9462 - 9470
  • [48] Different Configurations of Exhaust Gas Heat Recovery in Internal Combustion Engine: Evaluation on Different Driving Cycles Using Numerical Simulations
    Sara, Hanna
    Chalet, David
    Cormerais, Mickael
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2018, 10 (04)
  • [49] Numerical study of PCM solidification in a triplex tube heat exchanger with internal and external fins
    Al-Abidi, Abduljalil A.
    Mat, Sohif
    Sopian, K.
    Sulaiman, M. Y.
    Mohammad, Abdulrahman Th
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 61 : 684 - 695
  • [50] Experimental evaluation of an internal heat exchanger in a CO2 subcritical refrigeration cycle with gas-cooler
    Llopis, Rodrigo
    Sanz-Kock, Carlos
    Cabello, Ramon
    Sanchez, Daniel
    Torrella, Enrique
    APPLIED THERMAL ENGINEERING, 2015, 80 : 31 - 41