Experimental evaluation of a heat exchanger for different configurations between internal and external flow

被引:0
|
作者
Ramirez-Dolores, C. [1 ]
Andaverde, J. [2 ]
Ordonez-Castillo, L. [3 ]
Wong-Loya, J. [4 ]
机构
[1] Univ Nacl Autonoma Mexico, Posgrad Ingn, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[2] Univ Veracruzana, Fac Ciencias Quim, Coatzacoalcos 96538, Veracruz, Mexico
[3] Univ Nacl Autonoma Mexico, Licenciatura Ingn Energias Renovables, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
[4] Univ Nacl Autonoma Mexico, Inst Energias Renovables, Priv Xochicalco S-N, Temixco 62580, Morelos, Mexico
关键词
Fluid flow; Air-water heat exchanger; NTU-epsilon; Heat exchanger positions; THERMAL PERFORMANCE; NUMERICAL EVALUATION; AIR-QUALITY; EARTH; COMFORT; DESIGN; ENERGY; GROUNDWATER; BUILDINGS; EQUATION;
D O I
10.1007/s41939-024-00460-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present work, the determination of the thermal effectiveness and temperature of the air at the outlet of a scale prototype of a heat exchanger immersed in flowing water was developed experimentally. This depended on the position of the working fluid (air) and of the heat exchanger positioning configuration. The tested positions were parallel flow, quasi-parallel oblique, counterflow, quasi-counterflow oblique, and crossflow. The temperature of the air at the outlet of the heat exchanger and the thermal effectiveness are essential to determine the most convenient operating position of these systems, especially those related to shallow geothermal energy. The thermohydraulic aspects of the heat exchanger presented were evaluated, by the Number of Transfer Units-Effectiveness (NTU-epsilon) method, under conditions of water flow in a natural channel and air flow induced by a blower, the system was built from commercial copper pipe and temperature sensors were placed in both the exchanger and the water to record temperature changes. The results of this study indicate that when the exchanger is positioned in the oblique quasi-counterflow position and the oblique quasi-parallel position, it exhibits the lowest air outlet temperatures and highest thermal effectiveness, which is relevant for building cooling applications.
引用
收藏
页码:4117 / 4132
页数:16
相关论文
共 50 条
  • [31] Contrast experimental research between flower baffle heat exchanger and plate baffle heat exchanger
    Engineering College, Guangdong Ocean University, Zhanjiang 524005, China
    不详
    Huaxue Gongcheng, 2008, 12 (14-17):
  • [32] Experimental evaluation of sodium to air heat exchanger performance
    Vinod, V.
    Pathak, S. P.
    Paunikar, V. D.
    Kumar, V. A. Suresh
    Noushad, I. B.
    Rajan, K. K.
    ANNALS OF NUCLEAR ENERGY, 2013, 58 : 6 - 11
  • [33] Experimental Performance Evaluation of Tubular Manifold Heat Exchanger
    Ali, Muhammad Ansab
    Khan, Tariq S.
    Al Hajri, Ebrahim
    Khasawneh, Fadi
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2019, 11 (01)
  • [34] Experimental Evaluation of the Deposition Dynamics of Different Petroleum Blends in a Benchtop Heat Exchanger Test Instrument
    Villardi, H. G. D.
    de Medeiros, F. F.
    Orrico, L. C.
    de Souza, A. L. B.
    Junior, I. M.
    Liporace, F. S.
    Pessoa, F. L. P.
    ENERGIES, 2023, 16 (21)
  • [35] Experimental evaluation of pairs of inline tubes of different size as components for heat exchanger tube bundles
    Mavridou, Sofia G.
    Konstandinidis, Efstathios
    Bouris, Demetri G.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 90 : 280 - 290
  • [36] Experimental study on the heat transfer and pressure drop of a cross-flow heat exchanger with different pin–fin arrays
    Isak Kotcioglu
    Sinan Caliskan
    Senol Baskaya
    Heat and Mass Transfer, 2011, 47
  • [37] Heat Dissipation Characteristics of Plate-fin Heat Exchanger with Internal Flow Channel
    Cai H.
    Weng Z.
    Liao Y.
    Su L.
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2019, 47 (01): : 120 - 126and144
  • [38] Experimental study of fixed and fluidized beds of PCM with an internal heat exchanger
    Izquierdo-Barrientos, M. A.
    Fernandez-Torrijos, M.
    Almendros-Ibanez, J. A.
    Sobrino, C.
    APPLIED THERMAL ENGINEERING, 2016, 106 : 1042 - 1051
  • [39] Investigation of Heat-Transfer Process in Plate Heat Exchanger in Two Fluid-Flow Configurations
    Dardour, H.
    Mazouz, S.
    Cezac, P.
    Reneaume, J-M.
    Bellagi, A.
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2012, 26 (03) : 476 - 479
  • [40] Experimental comparison between different configurations of PCM based heat sinks for cooling electronic components
    Gharbi, Salma
    Harmand, Souad
    Ben Jabrallah, Sadok
    APPLIED THERMAL ENGINEERING, 2015, 87 : 454 - 462