Bond Strength of Post-installed Anchor Adhering to Damaged Concrete by Freeze-thaw Action

被引:0
|
作者
Yano, Yuga [1 ]
Shiokoshi, Taito [1 ]
Takase, Yuya [2 ]
Ishida, Yutaro [3 ]
Abe, Takahide [3 ]
Takahashi, Muneomi [4 ]
Ishigaki, Tsutomu [4 ]
机构
[1] Muroran Inst Technol, Coll Environm Technol, Mizumoto 27-1, Muroran, Hokkaido, Japan
[2] Muroran Inst Technol, Coll Design & Mfg Technol, Mizumoto 27-1, Muroran, Hokkaido, Japan
[3] TOBISHIMA Corp, Res & Dev Dept, Kimagase 5472, Noda, Chiba, Japan
[4] Hilti Japan Ltd, Sales Engn Div, Chigasakiminami 2-6-20,Tsuzuki Ku, Yokohama, Kanagawa, Japan
关键词
TENSILE BEHAVIOR;
D O I
10.3151/jact.22.178
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete (RC) structures in cold regions are susceptible to surface deterioration due to freeze-thaw cycles (FTC). For sustainable development goals (SDGs) and a decarbonized society, damaged structures should be repaired and reinforced. Post-installed anchors are commonly used for seismic retrofitting and equipment fixation. However, research on the bond characteristics of damaged concrete is limited. Therefore, in this study, the bonding performance of adhesive anchors in damaged concrete was investigated. Liquid nitrogen was employed to subject the concrete surface to FTC; subsequently, bond -slip tests were conducted with the degree of deterioration serving as a parameter. The results suggested, the bond strength decreased as the degree of damage increased. The reduction ratios of the post-installed anchor with epoxy and cement-based resins were almost identical. Furthermore, a bond strength equation was proposed by referring to the bond -slip model between the rebar and concrete ( fib 1990). The test results were well predicted with a correlation coefficient of 0.94. This study is based on previous studies (Yano et al . 2022, 2023) but presents new findings.
引用
收藏
页码:178 / 189
页数:12
相关论文
共 50 条
  • [21] FRACTURE STIMULATION OF THE ADHESIVE POST-INSTALLED ANCHOR APPLIED TO EXISTING CONCRETE STRUCTURES
    Kadono, Takuma
    Okazaki, Shinichiro
    Nakamura, Taro
    Kurumatani, Mao
    INTERNATIONAL JOURNAL OF GEOMATE, 2022, 22 (92): : 64 - 70
  • [22] Ottosen strength criterion of concrete by sea water freeze-thaw and erosion coupling action
    Zhang, Feng
    Li, Shu-Cai
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2010, 23 (05): : 64 - 69
  • [23] Water transport in concrete damaged by tensile loading and freeze-thaw cycling
    Yang, Zhifu
    Weiss, W. Jason
    Olek, Jan
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2006, 18 (03) : 424 - 434
  • [24] Freeze-thaw bond properties of new-old concrete
    李平先
    赵国藩
    张雷顺
    Journal of Harbin Institute of Technology, 2007, (06) : 842 - 845
  • [25] Freeze-thaw bond properties of new-old concrete
    Li, Ping-Xian
    Zhao, Guo-Fan
    Zhang, Lei-Shun
    Journal of Harbin Institute of Technology (New Series), 2007, 14 (06) : 842 - 845
  • [26] Evaluation of fracture behavior of high-strength hydraulic concrete damaged by freeze-thaw cycle test
    Zhu, Xiangyi
    Chen, Xudong
    Bai, Yin
    Ning, Yingjie
    Zhang, Wei
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 321
  • [27] Effect of Freeze-Thaw Cycles on FRP-Concrete Bond Strength in EBR and EBROG Systems
    Mostofinejad, Davood
    Mohammadi, Mahdie
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2020, 24 (03)
  • [28] Freeze-thaw degradation model and experimental analysis of rock-concrete interface bond strength
    Shen Y.
    Wei X.
    Yang G.
    Wang Y.
    Jia H.
    Zhang H.
    Zhang H.
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2020, 39 (03): : 480 - 490
  • [29] Experimental study on bond strength between BFRP bars and concrete under freeze-thaw cycles
    Wu X.
    Zhou K.
    Zhu Y.
    Yuan X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 : 442 - 447
  • [30] Bond Strength of Glass FRP Bars in Concrete Subjected to Freeze-Thaw Cycles and Sustained Loads
    Alves, Juliana
    El-Ragaby, Amr
    El-Salakawy, Ehab
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 368 - 371