Thermoluminescent dosimeters (TLD-100) for absorbed dose measurements in alpha-emitting radionuclides

被引:0
|
作者
White, Andrew J. [1 ]
Jollota, Sean P. [1 ]
Hammer, Cliff G. [1 ]
Khan, Ahtesham U. [1 ,2 ]
DeWerd, Larry A. [1 ]
Culberson, Wesley S. [1 ]
机构
[1] Univ Wisconsin, Madison Sch Med & Publ Hlth, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[2] Northwestern Mem Hosp, Dept Radiat Oncol, 250 E Huron St, Chicago, IL 60611 USA
关键词
Thermoluminescent dosimetry; TLD-100; Alpha-emitting radionuclides; Polonium-210; TL-LET RESPONSE; EFFICIENCY; LIF; THERAPY;
D O I
10.1016/j.apradiso.2024.111307
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Early works that used thermoluminescent dosimeters (TLDs) to measure absorbed dose from alpha particles reported relatively high variation (10%) between TLDs, which is undesirable for modern dosimetry applications. This work outlines a method to increase precision for absorbed dose measured using TLDs with alpha-emitting radionuclides by applying an alpha-specific chip factor (CF) that individually characterizes the TLD sensitivity to alpha particles. Variation between TLDs was reduced from 21.8% to 6.7% for the standard TLD chips and 7.9% to 3.3% for the thin TLD chips. It has been demonstrated by this work that TLD-100 can be calibrated to precisely measure the absorbed dose to water from alpha-emitting radionuclides.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Heterogeneity of dose distribution in normal tissues in case of radiopharmaceutical therapy with alpha-emitting radionuclides
    Wei Bo Li
    Céline Bouvier-Capely
    Clarita Saldarriaga Vargas
    Michelle Andersson
    Balázs Madas
    Radiation and Environmental Biophysics, 2022, 61 : 579 - 596
  • [42] POTENTIAL USE OF ALPHA-EMITTING RADIONUCLIDES IN THE TREATMENT OF CANCER
    WILBUR, DS
    ANTIBODY IMMUNOCONJUGATES AND RADIOPHARMACEUTICALS, 1991, 4 (01): : 85 - 97
  • [43] DOSIMETRY OF ALPHA-EMITTING RADIONUCLIDES IN BONE - A PRACTICAL APPROACH
    SONTAG, W
    HEALTH PHYSICS, 1987, 53 (05): : 495 - 501
  • [44] LIMITS FOR THE DISPOSAL OF WASTE CONTAINING ALPHA-EMITTING RADIONUCLIDES
    MOGHISSI, AA
    NUCLEAR AND CHEMICAL WASTE MANAGEMENT, 1983, 4 (01): : 9 - 10
  • [45] A Review of the Occurrence of Alpha-Emitting Radionuclides in Wild Mushrooms
    Struminska-Parulska, Dagmara
    Falandysz, Jerzy
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (21) : 1 - 20
  • [46] RESPONSE OF TLD-700 THERMOLUMINESCENT DOSIMETERS TO PROTONS AND ALPHA-PARTICLES
    JAHNERT, B
    HEALTH PHYSICS, 1972, 23 (01): : 112 - +
  • [47] Dose measurements in intraoral radiography using thermoluminescent dosimeters
    Azorin, C.
    Azorin, J.
    Aguirre, F.
    Rivera, T.
    VII INTERNATIONAL CONGRESS OF ENGINEERING PHYSICS, 2015, 582
  • [48] Comparison of the Calculated Absorbed Dose Using the Cadplan™ Treatment Planning Software and Tld-100 Measurements in an Alderson-Rando Phantom for a Bronchogenic Treatment
    Gutierrez Castillo, J. G.
    Alvarez Romero, J. T.
    Tones Calderon, A.
    Tovar M, V.
    XIII MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2014, 1626 : 125 - 129
  • [49] THERMOLUMINESCENT RESPONSE OF SINGLE-CRYSTAL TLD-100 TO LOW-ENERGY ELECTRONS
    LANSKY, JB
    MORAN, PR
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 561 - 561
  • [50] THERMOLUMINESCENT BEHAVIOR OF LIF (TLD-100) FROM 77 DEGREES TO 500 DEGREES K
    PODGORSAK, EB
    MORAN, PR
    CAMERON, JR
    JOURNAL OF APPLIED PHYSICS, 1971, 42 (07) : 2761 - +