Comparison of the Calculated Absorbed Dose Using the Cadplan™ Treatment Planning Software and Tld-100 Measurements in an Alderson-Rando Phantom for a Bronchogenic Treatment

被引:0
|
作者
Gutierrez Castillo, J. G. [1 ]
Alvarez Romero, J. T. [2 ]
Tones Calderon, A. [1 ]
Tovar M, V. [2 ]
机构
[1] Hosp Oncol, IMSS, CMN Siglo XXI, Dept Fis, Cuauhtemoc 330 Col Doctores, Mexico City, DF, Mexico
[2] Dept Metrologia ININ, SSDL, Mexico City 15245, DF, Mexico
来源
关键词
D O I
10.1063/1.4901375
中图分类号
O59 [应用物理学];
学科分类号
摘要
To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) vs D-W, to several cavity theories. The traceability for the D-W is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < +/- 3%
引用
收藏
页码:125 / 129
页数:5
相关论文
共 21 条
  • [1] The comparison of dose distribution calculated by inverse planning software of Cadplan® and Eclipse® in the treatment of anal carcinoma
    Arponen, P
    Tenhunen, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S171 - S171
  • [2] Comparison of treatment planning dose calculations with measurements and Monte Carlo calculations in a RANDO phantom
    Wyatt, M
    Corredor, C
    Tamimi, M
    Miller, LF
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 461 - 465
  • [3] Comparison of Calculated Dose by Helical Tomotherapy Treatment Planning Machine and Measured Dose of Radiophotoluminescence Glass Dosimeter in Lung Lesions Using Rando Phantom
    Yamazaki, Hideya
    Iwama, Kazuki
    Nishimura, Takuya
    Iwai, Yasunori
    Aibe, Norihiro
    Takenaka, Tadashi
    Miyake, Shunsuke
    Tanaka, Eiichi
    Yoshida, Ken
    Oota, Yoshitaka
    Ikeno, Hiroyasu
    Nakamura, Satoakai
    Okabe, Haruumi
    ANTICANCER RESEARCH, 2013, 33 (04) : 1679 - 1684
  • [4] Outfield radiation dose determination by TLD-100 in the treatment of breast cancer using hypofractionated radiation therapy
    Kafadar, Vural E.
    Yegen, Omer
    Cifci, Sule Baz
    Karslioglu, Ihsan
    EUROPEAN PHYSICAL JOURNAL PLUS, 2023, 138 (10):
  • [5] Outfield radiation dose determination by TLD-100 in the treatment of breast cancer using hypofractionated radiation therapy
    Vural E. Kafadar
    Ömer Yegen
    Şule Baz Çifci
    İhsan Karslıoğlu
    The European Physical Journal Plus, 138
  • [6] Dose measurements of parotid glands and spinal cord in conventional treatment of nasopharyngeal carcinoma using RANDO Phantom and Thermoluminescent Dosimeters
    Bahreyni Toossi, Mohammad Taghi
    Bolookat, Eftekhar Rajab
    Salek, Raham
    Layegh, Mohsen
    Iranian Journal of Medical Physics, 2015, 12 (02) : 78 - 84
  • [7] Comparison of Dose Distributions Calculated Using Different Planning Systems with Radiochromic Film Measurements in An Inhomogeneous Phantom
    Lovelock, D.
    Lim, S.
    Yorke, E.
    Kirov, A.
    LoSasso, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3828 - 3828
  • [8] Critical Comparison of Measured and Calculated Prostate Dose using Multiple Treatment Modalities and Planning Systems in a Phantom with Bilateral Hip Prosthesis
    Rakowski, J. T.
    Saini, J.
    Weyh, A.
    Starin, R.
    Kumar, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S737 - S737
  • [9] Implementation of Alpha-Specific Chip Factors to Reduce Variation in Absorbed Dose to Water Measurements of Alpha-Emitting Radionuclides Using Thermoluminescent Dosimeters (TLD-100)
    White, A. J.
    Jollota, S.
    Hammer, C. G.
    Khan, A. U.
    DeWerd, L. A.
    Culberson, W. S.
    MEDICAL PHYSICS, 2024, 51 (09) : 6563 - 6563
  • [10] Comparison of treatment planning system and Monte Carlo calculated dose distributions in an extreme water-lung interface phantom
    Gagne, I.
    Zavgorodni, S.
    MEDICAL PHYSICS, 2006, 33 (07) : 2657 - 2658