Position dispersive X-ray fluorescence

被引:0
|
作者
Webster J.L.V. [1 ,2 ]
Mcllquham J.D. [1 ,2 ]
Ganly B. [2 ]
机构
[1] University of Wollongong, Northfields Ave, Wollongong, 2522, NSW
[2] CSIRO, Building 67, New Illawarra Rd, Lucas Heights, 2234, NSW
来源
关键词
The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Jack Webster reports financial support; equipment; drugs; or supplies; and writing assistance were provided by CSIRO Mineral Resources. Brianna Ganly reports financial support and equipment; or supplies were provided by CSIRO Mineral Resources. Jack Mcilquham reports financial support and equipment; or supplies were provided by CSIRO Mineral Resources. Jack Webster reports a relationship with University of Wollongong Faculty of Engineering and Information Sciences that includes: employment. Brianna Ganly reports a relationship with CSIRO Mineral Resources that includes: employment. Jack Mcilquham reports a relationship with CSIRO Mineral Resources that includes: employment;
D O I
10.1016/j.radphyschem.2022.110173
中图分类号
学科分类号
摘要
A novel scanning-free wavelength dispersive X-ray fluorescence spectrometer has been developed by combining low power X-ray tubes with X-ray optics. The X-rays are focused to a single point on the sample and then dispersed onto a flat diffracting crystal where they are spread depending on their energy through Bragg's law of diffraction onto a silicon strip detector. Throughout this study, the proposed method is referred to as Position Dispersive X-ray Fluorescence (PDXRF). The X-ray emission spectra of vanadium and copper as well as, CuO, CuS2 and V2O5 were measured. In the spectrometer energy resolutions of 3.14 eV and 8.94 eV FWHM were measured for V and Cu when measuring over a range of 4.8–5.8 keV and 6.2–9.1 keV respectively. The Kβ line shapes were fitted with a series of Voigt profiles and the energies and intensities of the Kβ valence transition peak, Kβ2,5, were determined. There was also sufficient variation in the intensity ratio of Kβ2,5/Kβ1,3 that the oxygen and sulphur compounds of V and Cu could be successfully observed and measured. The result demonstrates that this experimental setup is capable of measuring the Kβ line shape at resolutions of a few eV, allowing for chemical state analysis to be performed on 3d transition metals and their compounds such as the measurement of redox reactions to aid in battery development. © 2022
引用
收藏
相关论文
共 50 条
  • [21] Gauge of an energy-dispersive X-ray fluorescence analyzer
    Bukin, KV
    Nakhabtsev, VS
    Romanova, NE
    Kirillov, VN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (03) : 393 - 397
  • [22] Novel wavelength-dispersive X-ray fluorescence spectrometer
    Firsov, A.
    Erko, A.
    Senf, F.
    Rehanek, J.
    Brzhezinskaya, M.
    Wernet, R. Mitzner Ph
    Foehlisch, A.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [23] ENERGY DISPERSIVE X-RAY FLUORESCENCE (EDXRF) ANALYSIS OF STEELS
    Toma, Lucica Grigora
    Ion, Rodica Mariana
    Fierascu, Radu Claudiu
    Ion, Nelu
    Popescu, Ileana Nicoleta
    JOURNAL OF SCIENCE AND ARTS, 2010, (02): : 385 - 390
  • [24] Petrochemical applications of wavelength dispersive X-ray fluorescence spectrometry
    Lienemann, CP
    Roche, E
    Yellepeddi, R
    Bonvin, D
    Matula, G
    JOURNAL DE PHYSIQUE IV, 2004, 118 : 143 - 147
  • [25] X-ray fluorescence and energy dispersive x-ray diffraction for the quantification of elemental concentrations in breast tissue
    Geraki, K
    Farquharson, MJ
    Bradley, DA
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (01): : 99 - 110
  • [26] ENERGY-DISPERSIVE X-RAY ANALYSIS - COMPARISON BETWEEN X-RAY MICROANALYSIS AND X-RAY-FLUORESCENCE ANALYSIS
    LINNEMANN, B
    REIMER, L
    MIKROSKOPIE, 1978, 34 (5-6) : 145 - 146
  • [27] Energy-dispersive vs wavelength-dispersive X-ray fluorescence spectrometry
    Brill, M
    METALL, 1996, 50 (7-8): : 504 - 511
  • [28] Comparative study of energy dispersive X-ray fluorescence spectrometry, wavelength dispersive X-ray fluorescence spectrometry and inductively coupled plasma-atomic emission spectrometry
    Rahmani, A
    Benyaïch, F
    Bounakhla, M
    Bilal, E
    Moutte, J
    Gruffat, JJ
    Zahry, F
    JOURNAL DE PHYSIQUE IV, 2004, 118 : 447 - 455
  • [29] Determination of the emission spectrum of an X-ray tube of a wavelength-dispersive series X-ray fluorescence spectrometer
    Oskolok, K.V.
    Monogarova, O.V.
    Journal of Analytical Chemistry, 2008, 63 (12): : 1176 - 1181
  • [30] Measurements of the K X-ray intensity ratios by using energy-dispersive X-ray fluorescence spectrometry
    Guerol, A.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (03) : 372 - 376