Effect of forced ventilation strategy on the thermal performance of finned-Trombe wall

被引:2
|
作者
Wu, Shuang-Ying [1 ,2 ]
Zheng, Hao [2 ]
Xiao, Lan [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Sch Energy & Power Engn, Chongqing 400044, Peoples R China
来源
关键词
Finned-Trombe wall; Geometric structure parameters; Forced ventilation; Thermal performance; Convective heat transfer; NATURAL-CONVECTION; HEAT-TRANSFER; VENETIAN BLIND; RESIDENTIAL BUILDINGS; NUMERICAL-ANALYSIS; SHAPED CHANNELS; SOLAR WALLS; ENERGY; SYSTEMS; BEHAVIOR;
D O I
10.1016/j.jobe.2024.109021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Compared with the natural ventilation (NV) strategy, the forced ventilation (FV) strategy has inherent characteristics. However, the research on the effect of FV strategy on the thermal performance of finned-Trombe wall (F-TW) is still lacking so far. To fill this gap, in this study, a 3D numerical model that only takes into account heat loss through the glass cover was created to evaluate the impacts of ventilation strategy, inlet airflow speed, fin geometric factors and external environmental parameters on the thermal performance of F-TW. The main findings demonstrate that the thermal efficiency q th and exergic efficiency q ex under FV strategy first grow and then decline as the inlet airflow speed u in increases, with the extreme value appearing at around 0.50 m/s of u in . The optimal q th and q ex can reach 99.76% and 14.89% respectively when the relative fin height h * = 0.90 and relative fin spacing s * = 0.02. q th and q ex exhibit a tendency of steady growth with increasing h * and decreasing s *. The h * has a stronger impact on the thermal performance than s *. The FV strategy can not only improve the F-TW ' s thermal performance by effectively changing the flow and temperature fields in the channel, but also alters the variation law between s * and thermal performance. The optimal q th and q ex are both increased by 39.18%, compared with the NV strategy, and 13.49%, in comparison to the case without fins. Improving the solar radiation intensity, reducing the outdoor ambient wind speed and increasing the outdoor ambient temperature are beneficial to the F-TW ' s thermal performance. Aiming at F-TW, the significance of this study is to provide the basis for the performance assessment under the FV strategy, as well as the selection of different ventilation strategies.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Effect of cooling method on the performance of PV/Trombe wall: Experimental assessment
    Abdullah, Abdullah A.
    Attulla, Faris S.
    Ahmed, Omer K.
    Algburi, Sameer
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 30
  • [32] Effect of dusty weather on the performance of the PV/Trombe wall: Experimental assessment
    Abdullah, Abdullah A.
    Atallah, Faris S.
    Ahmed, Omer K.
    Alguburi, Sameer
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 39
  • [33] PASSIVE FACADE SOLUTIONS: TROMBE WALL THERMAL PERFORMANCE AND GLAZING DAYLIGHTING PERFORMANCE FOR GUIMARAES - PORTUGAL
    Sacht, Helenice Maria
    Braganca, Luis
    Almeida, Manuela
    Caram, Rosama
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 983 - 989
  • [34] Thermal Performance Analysis of Trombe Wall for Passive Solar Building with Computational Fluid Dynamics
    Dhahri, Maher
    Aouinet, Hana
    Sammouda, Habib
    SUSTAINABLE ENERGY-WATER-ENVIRONMENT NEXUS IN DESERTS, 2022, : 409 - 417
  • [35] Numerical study on the photo thermal and electrical performance of a novel trombe wall with pv cells
    Dept. of Thermal Science and Energy Engineering, Univ. of Science and Technology of China, Hefei 230027, China
    Taiyangneng Xuebao, 2006, 9 (870-877):
  • [36] Performance study of a novel multi-functional Trombe wall with air purification, photovoltaic, heating and ventilation
    Wu, Shuang-Ying
    Xu, Li
    Xiao, Lan
    ENERGY CONVERSION AND MANAGEMENT, 2020, 203
  • [37] Numerical Study on the Thermal Performance of Trombe Wall for Passive Solar Building in Semiarid Climate
    Dhahri, Maher
    Khalilpoor, Nima
    Aouinet, Hana
    Issakhov, Alibek
    Sammouda, Habib
    Emani, Sampath
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2021, 2021
  • [38] Performance analysis on a wood-color thermal catalytic Trombe wall in wood buildings
    Wu, Huabo
    Li, Niansi
    Zhang, Guoyu
    Zhang, Guoji
    Ji, Jie
    Yu, Bendong
    ENERGY AND BUILDINGS, 2024, 308
  • [39] Thermal performance analysis of a Trombe wall with the multi-row channel PCM wallboard
    Li, Yazi
    Lei, Yonggang
    Yan, Yao
    Song, Chongfang
    ENERGY, 2024, 313
  • [40] Effects of external insulation component on thermal performance of a Trombe wall with phase change materials
    Liu, Yan
    Hou, Liqiang
    Yang, Yidong
    Feng, Yinping
    Yang, Liu
    Gao, Qinglong
    SOLAR ENERGY, 2020, 204 (204) : 115 - 133