Effect of forced ventilation strategy on the thermal performance of finned-Trombe wall

被引:2
|
作者
Wu, Shuang-Ying [1 ,2 ]
Zheng, Hao [2 ]
Xiao, Lan [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Sch Energy & Power Engn, Chongqing 400044, Peoples R China
来源
关键词
Finned-Trombe wall; Geometric structure parameters; Forced ventilation; Thermal performance; Convective heat transfer; NATURAL-CONVECTION; HEAT-TRANSFER; VENETIAN BLIND; RESIDENTIAL BUILDINGS; NUMERICAL-ANALYSIS; SHAPED CHANNELS; SOLAR WALLS; ENERGY; SYSTEMS; BEHAVIOR;
D O I
10.1016/j.jobe.2024.109021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Compared with the natural ventilation (NV) strategy, the forced ventilation (FV) strategy has inherent characteristics. However, the research on the effect of FV strategy on the thermal performance of finned-Trombe wall (F-TW) is still lacking so far. To fill this gap, in this study, a 3D numerical model that only takes into account heat loss through the glass cover was created to evaluate the impacts of ventilation strategy, inlet airflow speed, fin geometric factors and external environmental parameters on the thermal performance of F-TW. The main findings demonstrate that the thermal efficiency q th and exergic efficiency q ex under FV strategy first grow and then decline as the inlet airflow speed u in increases, with the extreme value appearing at around 0.50 m/s of u in . The optimal q th and q ex can reach 99.76% and 14.89% respectively when the relative fin height h * = 0.90 and relative fin spacing s * = 0.02. q th and q ex exhibit a tendency of steady growth with increasing h * and decreasing s *. The h * has a stronger impact on the thermal performance than s *. The FV strategy can not only improve the F-TW ' s thermal performance by effectively changing the flow and temperature fields in the channel, but also alters the variation law between s * and thermal performance. The optimal q th and q ex are both increased by 39.18%, compared with the NV strategy, and 13.49%, in comparison to the case without fins. Improving the solar radiation intensity, reducing the outdoor ambient wind speed and increasing the outdoor ambient temperature are beneficial to the F-TW ' s thermal performance. Aiming at F-TW, the significance of this study is to provide the basis for the performance assessment under the FV strategy, as well as the selection of different ventilation strategies.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Numerically predicting the effect of fin on solar Trombe wall performance
    Wu, Shuang-Ying
    Yan, Rong-Rong
    Xiao, Lan
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [22] Theoretical study on thermal performance of Trombe wall combined with solar air collector
    Bie, Yu
    Zhou, Fang
    Hu, Ming Fu
    Peng, Qian
    Mao, Wen Yuan
    Chang, Jing Hua
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 208 - +
  • [23] Transient Simulation of the Thermal Performance of a Novel Phase Change Material Trombe Wall
    Zhang, Tianhu
    Wang, Hai
    Ding, Jieran
    Tang, Shoufeng
    Yuan, Deling
    Rao, Yandi
    COATINGS, 2025, 15 (03):
  • [24] Investigation on the thermal performance of a composite Trombe wall under steady state condition
    Zhou, Liqun
    Huo, Junpeng
    Zhou, Tong
    Jin, Shufeng
    ENERGY AND BUILDINGS, 2020, 214
  • [25] Thermal performance of a novel Trombe wall enhanced by a solar energy focusing approach
    Xianzhang Dong
    Huigang Xiao
    Minglei Ma
    Low-carbon Materials and Green Construction, 2 (1):
  • [26] Dynamic thermal performance simulation of an improved passive solar house with Trombe wall
    Zhao, Jinling
    Chen, Bin
    Liu, Jingjun
    Wang, Yongxue
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 2234 - 2239
  • [27] Experimental and numerical study on thermal performance of an unvented Trombe wall associated with internal thermal fins
    Abbassi, Fakhreddine
    Dehmani, Leila
    ENERGY AND BUILDINGS, 2015, 105 : 119 - 128
  • [28] Multi-objective optimization and thermal performance evaluation of a novel Trombe wall
    Chen, Tingsen
    Liu, Shuli
    Wang, Yihan
    Shen, Yongliang
    Ji, Wenjie
    Zhang, Shaoliang
    Li, Suo
    Khan, Sheher Yar
    Kumar, Mahesh
    ENERGY, 2025, 323
  • [29] THERMAL PERFORMANCE OF THE CLEAR BLOCK WALL FOR VENTILATION
    Ananacha, Thana
    INTERNATIONAL JOURNAL OF GEOMATE, 2022, 23 (96): : 25 - 31
  • [30] Effect of key parameters on the transient thermal performance of a building envelope with Trombe wall containing phase change material
    Zhou, Shiqiang
    Bai, Fan
    Razaqpur, Ghani
    Wang, Bing
    ENERGY AND BUILDINGS, 2023, 284