Effect of forced ventilation strategy on the thermal performance of finned-Trombe wall

被引:2
|
作者
Wu, Shuang-Ying [1 ,2 ]
Zheng, Hao [2 ]
Xiao, Lan [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Sch Energy & Power Engn, Chongqing 400044, Peoples R China
来源
关键词
Finned-Trombe wall; Geometric structure parameters; Forced ventilation; Thermal performance; Convective heat transfer; NATURAL-CONVECTION; HEAT-TRANSFER; VENETIAN BLIND; RESIDENTIAL BUILDINGS; NUMERICAL-ANALYSIS; SHAPED CHANNELS; SOLAR WALLS; ENERGY; SYSTEMS; BEHAVIOR;
D O I
10.1016/j.jobe.2024.109021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Compared with the natural ventilation (NV) strategy, the forced ventilation (FV) strategy has inherent characteristics. However, the research on the effect of FV strategy on the thermal performance of finned-Trombe wall (F-TW) is still lacking so far. To fill this gap, in this study, a 3D numerical model that only takes into account heat loss through the glass cover was created to evaluate the impacts of ventilation strategy, inlet airflow speed, fin geometric factors and external environmental parameters on the thermal performance of F-TW. The main findings demonstrate that the thermal efficiency q th and exergic efficiency q ex under FV strategy first grow and then decline as the inlet airflow speed u in increases, with the extreme value appearing at around 0.50 m/s of u in . The optimal q th and q ex can reach 99.76% and 14.89% respectively when the relative fin height h * = 0.90 and relative fin spacing s * = 0.02. q th and q ex exhibit a tendency of steady growth with increasing h * and decreasing s *. The h * has a stronger impact on the thermal performance than s *. The FV strategy can not only improve the F-TW ' s thermal performance by effectively changing the flow and temperature fields in the channel, but also alters the variation law between s * and thermal performance. The optimal q th and q ex are both increased by 39.18%, compared with the NV strategy, and 13.49%, in comparison to the case without fins. Improving the solar radiation intensity, reducing the outdoor ambient wind speed and increasing the outdoor ambient temperature are beneficial to the F-TW ' s thermal performance. Aiming at F-TW, the significance of this study is to provide the basis for the performance assessment under the FV strategy, as well as the selection of different ventilation strategies.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Experimental investigation on the impact of fin structure factors on the finned-Trombe wall thermal performance
    Wu, Shuang-Ying
    Zheng, Hao
    Xiao, Lan
    Xiang, Yu
    JOURNAL OF BUILDING ENGINEERING, 2023, 70
  • [2] The thermal performance of composite trombe wall
    Yang, Zhao
    Xu, Xiao li
    Solar Engineering 2005, 2006, : 133 - 141
  • [3] Thermal performance and ventilation analysis of a zigzag Trombe wall: Full numerical and experimental investigations
    Zhang, Hong-Liang
    Li, Bin
    Shi, Dun-Ke
    Zhao, Fu-Yun
    ENERGY AND BUILDINGS, 2024, 306
  • [4] A numerical study on the effect of vent/wall area ratio on Trombe wall thermal performance
    Kaya, Ercan Serif
    Aksel, Murat
    Yigit, Sadik
    Acikara, Turgut
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING SUSTAINABILITY, 2021, 174 (05) : 224 - 234
  • [5] An analytical approach to assess the influence of the massive wall material, thickness and ventilation system on the Trombe wall thermal performance
    Briga Sa, Ana Cristina
    Martins, Analisa
    Boaventura-Cunha, Jose
    Lanzinha, Joao Carlos
    Paiva, Anabela
    JOURNAL OF BUILDING PHYSICS, 2018, 41 (05) : 445 - 468
  • [6] Effect of sunshade thermal insulation curtain position and ventilation mode on performance of building with phase change material Trombe wall
    Sun, Yafen
    Li, Xiaohan
    Cai, Wenfeng
    Zhang, Nan
    Zhang, Zhaoli
    Dzhonova, Daniela
    Yuan, Yanping
    APPLIED THERMAL ENGINEERING, 2025, 263
  • [7] Numerical Simulation on Performance of Finned-Built-Middle Photovoltaic Trombe Wall
    Xiao, Lan
    Zhang, Yuqing
    Wu, Shuangying
    Xu, Shijie
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2024, 45 (07): : 1917 - 1923
  • [8] Influence of a Built-in Finned Trombe Wall on the Indoor Thermal Environment in Cold Regions
    Qi, Xiaobing
    Wang, Jialong
    Wang, Ye
    ENERGIES, 2024, 17 (08)
  • [9] Investigation on the Performance of a Trombe Wall Driven by Thermal Pressure
    Hou, Jun-Qin
    Lei, Yong-Gang
    Wang, Fei
    Wang, Xun
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 200 - +
  • [10] Numerical study on thermal performance of PCM Trombe Wall
    Li, Shanshan
    Zhu, Na
    Hu, Pingfang
    Lei, Fei
    Deng, Renjie
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 2441 - 2447