Automated Test for Monthly Quality Assurance of Optical Surface Imaging Dynamic Localization Accuracy

被引:0
|
作者
Young, Kaleigh [1 ]
Wright, Eric A. [2 ]
机构
[1] Univ British Columbia, Fac Med, Okanagan Campus, Kelowna, BC, Canada
[2] Sunnybrook Hlth Sci Ctr, Odette Canc Ctr, Med Phys, Toronto, ON, Canada
关键词
optical imaging; radiation therapy technology; optical surface imaging; surface-guided radiotherapy; general radiation oncology;
D O I
10.7759/cureus.56242
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The American Association of Physicists in Medicine (AAPM) recently published the report of Task Group (TG) 302, which provides recommendations on acceptance, commissioning, and ongoing routine quality assurance (QA) for surface-guided radiation therapy (SGRT) systems. One of the recommended monthly QA tests is a dynamic localization accuracy test. This work aimed to develop an automated procedure for monthly SGRT dynamic localization QA. An anthropomorphic head phantom was rigidly attached to the 6-dof couch of a TrueBeam linac. TrueBeam Developer Mode was used to take an MV image of the phantom at the starting position, then automatically drive the couch through a series of translations and rotations, taking an MV image after each translation. The Identify SGRT system monitored the motion of the phantom surface from the starting position. Translations assessed on MV images were compared to translations reported in trajectory log files and Identify log files. Rotations were compared between trajectory log files and Identify log files. Three experiments were conducted. None of the translations or rotations from any experiment exceeded the tolerance values for stereotactic ablative body radiation therapy (SABR) recommended by AAPM TG-142. Maximum deviations from the expected translation values from MV imaging, trajectory log files, and Identify log files were -0.94mm, -0.11mm, and -0.78mm, respectively. Maximum deviations from the expected rotation values from trajectory log files and Identify log files were 0.01 and -0.2 degrees, respectively. The proposed method is a simple automated way to complete monthly dynamic localization QA of SGRT systems.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A monthly quality assurance procedure for 3D surface imaging
    Wooten, H. Omar
    Klein, Eric E.
    Gokrhoo, Garima
    Santanam, Lakshmi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (01): : 234 - 238
  • [2] Automated quality assurance in mammographic Imaging
    Blot, L
    Zwiggelaar, R
    Hobulinka, M
    Davis, A
    IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 641 - 647
  • [3] Tool for Automated Monthly Quality Assurance on Tomotherapy Using Film
    Yaddanapudi, S.
    Ramirez, J. Garcia
    Green, O. Pechenaya
    Wooten, H.
    Palaniswaamy, G.
    Rangaraj, D.
    Mutic, S.
    Goddu, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Automated Quality Assurance Applied to Mammographic Imaging
    Lilian Blot
    Anne Davis
    Mike Holubinka
    Robert Martí
    Reyer Zwiggelaar
    EURASIP Journal on Advances in Signal Processing, 2002
  • [5] Automated quality assurance applied to mammographic imaging
    Blot, L. (lb@sys.uea.ac.uk), 1600, Hindawi Publishing Corporation (2002):
  • [6] Automated quality assurance applied to mammographic imaging
    Blot, L
    Davis, A
    Holubinka, M
    Marti, R
    Zwiggelaar, R
    EURASIP JOURNAL ON APPLIED SIGNAL PROCESSING, 2002, 2002 (07) : 736 - 745
  • [7] An Automated Test Generation Technique for Software Quality Assurance
    Xu, Dianxiang
    Xu, Weifeng
    Kent, Michael
    Thomas, Lijo
    Wang, Linzhang
    IEEE TRANSACTIONS ON RELIABILITY, 2015, 64 (01) : 247 - 268
  • [8] Quantification accuracy for dynamic contrast enhanced (DCE) CT imaging: phantom and quality assurance framework
    Coolens, C.
    Mohseni, H.
    Dhodi, S.
    Ma, S.
    Keller, H.
    Jaffray, D. A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 192 - 198
  • [9] Comprehensive Automated Quality Assurance of Daily Surface Observations
    Durre, Imke
    Menne, Matthew J.
    Gleason, Byron E.
    Houston, Tamara G.
    Vose, Russell S.
    JOURNAL OF APPLIED METEOROLOGY AND CLIMATOLOGY, 2010, 49 (08) : 1615 - 1633
  • [10] A semi-automated quality assurance toolbox for diagnostic imaging
    Constantinou, Christodoulos
    Grondoudis, Andreas
    Christoforou, Andreas
    Lanitis, Andreas
    Constantinides, Christakis
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2014, 14 (02) : 159 - 180