Position Sensitive Detector Based on Microchannel Plates for Measuring the Characteristics of Fission Fragments at the MAVR Facility

被引:0
|
作者
Aznabaev, D. [1 ,2 ]
Isataev, T. [1 ,2 ]
Lukyanov, S. M. [1 ]
Smirnov, V. I. [1 ]
Stukalov, S. S. [1 ]
Solodov, A. N. [1 ]
机构
[1] Joint Inst Nucl Res, Dubna 141980, Moscow Oblast, Russia
[2] Inst Nucl Phys, Alma Ata 050032, Kazakhstan
关键词
Charged particles - Fission reactions - Microchannels - Nuclear reactions;
D O I
10.1134/S0020441224700027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the results of measurements of fission fragments using a time-of-flight system with a position-sensitive detector based on microchannel plates designed to measure the masses of nuclear reaction products at the MAVR facility. The advantage of such MCPs is their high positional sensitivity and high efficiency of registration of heavy charged particles with low energy. The paper presents a technical description of the fission fragments registration system and the results of measuring the parameters of a position-sensitive detector based on large-area microchannel plates (40 x 60 mm(2)) obtained by measuring Cf-252 spontaneous fission fragments. The coordinate resolution along the X and Y axes was determined when fission fragments were registered in the N-14+Au-192 reaction at the MAVR installation. The time resolution of the PSD was obtained by registering the time of flight of alpha particles emitted by the radioactive source Ra-226.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [41] MASS-SPECTROMETER WITH A MULTICHANNEL ION DETECTOR BASED ON MICROCHANNEL PLATES
    DUKHANOV, VI
    ZELENKOV, AG
    KURASHOV, AA
    MAZUROV, IB
    RODIONOV, YF
    SERIKOV, IN
    TARASEVICH, VP
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1980, 58 (1-2): : 161 - 164
  • [42] A new hard X-ray detector based on microchannel plates
    Shikhaliev, PM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (02): : 307 - 311
  • [43] A POSITION-SENSITIVE MICROCHANNEL-PLATE DETECTOR FOR 27-KEV IONS
    ZHANG, YJ
    WEI, YQ
    WANG, QY
    QIAN, WG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01): : 76 - 82
  • [44] Position-sensitive microchannel-plate detector for 27-keV ions
    Zhang, Yingji
    Wei, Yongqin
    Wang, Qiuyu
    Qian, Wenguo
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991, A302 (01):
  • [45] A fast position sensitive microchannel plate detector for ray-tracing of charged particles
    Odland, OH
    Mittig, W
    LepineSzily, A
    Fremont, G
    Chartier, M
    MacCormick, M
    Casandjian, JM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (1-2): : 149 - 154
  • [46] X-Ray Image Registration by a Detector Based on Microchannel Plates
    Yu. M. Yarmoshenko
    I. E. Kantur
    V. E. Dolgikh
    T. V. Kuznetsova
    Instruments and Experimental Techniques, 2023, 66 : 445 - 450
  • [47] New hard X-ray detector based on microchannel plates
    A.F. Ioffe Physical-Technical Inst, St. Petersburg, Russia
    Nucl Instrum Methods Phys Res Sect A, 2 (307-311):
  • [48] X-Ray Image Registration by a Detector Based on Microchannel Plates
    Yarmoshenko, Yu. M.
    Kantur, I. E.
    Dolgikh, V. E.
    Kuznetsova, T. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2023, 66 (03) : 445 - 450
  • [49] Hard X-ray beam detector based on microchannel plates
    Shikhaliev, P.M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 369 (01): : 147 - 150
  • [50] POSITION-SENSITIVE MULTIWIRE PROPORTIONAL CHAMBER FOR FISSION FRAGMENTS WITH LARGE SOLID ANGLE
    GLASSEL, P
    ROSLER, H
    MANNER, R
    SPECHT, HJ
    NUCLEAR INSTRUMENTS & METHODS, 1977, 141 (01): : 111 - 114