Blood Pressure Measurement Device Accuracy Evaluation: Statistical Considerations with an Implementation in R

被引:2
|
作者
Chandel, Tanvi [1 ]
Miranda, Victor [2 ]
Lowe, Andrew [1 ]
Lee, Tet Chuan [1 ]
机构
[1] Auckland Univ Technol, Inst Biomed Technol, Auckland 1010, New Zealand
[2] Auckland Univ Technol, Dept Math Sci, Auckland 1010, New Zealand
关键词
blood pressure; ANSI/AAMI-SP10; standards; blood pressure measurement device; probability of acceptance; HYPERTENSION-INTERNATIONAL-PROTOCOL; PULSE TRANSIT-TIME; EUROPEAN-SOCIETY; VALIDATION;
D O I
10.3390/technologies12040044
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Inaccuracies from devices for non-invasive blood pressure measurements have been well reported with clinical consequences. International standards, such as ISO 81060-2 and the seminal AAMI/ANSI SP10, define protocols and acceptance criteria for these devices. Prior to applying these standards, a sample size of N >= 85 is mandatory, that is, the number of distinct subcjects used to calculate device inaccuracies. Often, it is not possible to gather such a large sample. Many studies apply these standards with a smaller sample. The objective of the paper is to introduce a methodology that broadens the method first developed by the AAMI Sphygmomanometer Committee for accepting a blood pressure measurement device. We study changes in the acceptance region for various sample sizes using the sampling distribution for proportions and introduce a methodology for estimating the exact probability of the acceptance of a device. This enables the comparison of the accuracies of existing device development techniques even if they were studied with a smaller sample size. The study is useful in assisting BP measurement device manufacturers. To assist clinicians, we present a newly developed "bpAcc" package in R to evaluate acceptance statistics for various sample sizes.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Accuracy of the Braun 2550(UG) device in home blood pressure measurement
    Nolly, H
    Raposo, I
    Nolly, A
    JOURNAL OF HYPERTENSION, 2003, 21 : S23 - S23
  • [2] EVALUATION OF A DIGITAL DEVICE FOR HOME BLOOD-PRESSURE MEASUREMENT
    BURRIS, JF
    PHILLIPS, M
    CLINICAL RESEARCH, 1982, 30 (02): : A638 - A638
  • [3] Evaluation of Applicability and Accuracy of a New Form of Cuffless Blood Pressure Measurement Device, CART-I Plus
    Shin, Jeong-Hun
    Shin, Jinho
    KOREAN CIRCULATION JOURNAL, 2024, 54 (02) : 105 - 107
  • [4] Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals
    Mukkamala, Ramakrishna
    Yavarimanesh, Mohammad
    Natarajan, Keerthana
    Hahn, Jin-Oh
    Kyriakoulis, Konstantinos G.
    Avolio, Alberto P.
    Stergiou, George S.
    HYPERTENSION, 2021, 78 (05) : 1161 - 1167
  • [5] Design Considerations for the Integration of Two Noninvasive Methods of Blood Pressure Measurement in a Portable Device
    Meneses, G. A.
    Lemos, J. D.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 834 - 837
  • [6] Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device
    Maestri, R
    Pinna, GD
    Robbi, E
    Capomolla, S
    La Rovere, MT
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (06) : 1125 - 1136
  • [7] Accuracy of Doppler blood pressure measurement in HeartMate 3 ventricular assist device patients
    Li, Song
    Beckman, Jennifer A.
    Welch, Nathan G.
    Cheng, Richard K.
    Rockom, Sunny W.
    Levy, Wayne C.
    O'Brien, Kevin D.
    Dardas, Todd F.
    Lin, Shin
    Leary, Peter J.
    Kirkpatrick, James
    McCabe, James M.
    Bjelkengren, Jason
    Chassagne, Fanette
    Aliseda, Alberto
    Zimpfer, Daniel
    Mahr, Claudius
    ESC HEART FAILURE, 2020, 7 (06): : 4241 - 4246
  • [8] Wearable blood pressure measurement device using cuffless blood pressure measurement methods
    Dohi T.
    Waki K.
    IEEJ Transactions on Sensors and Micromachines, 2016, 136 (09) : 370 - 376
  • [9] DIAGNOSTIC ACCURACY OF A CUFFLESS BLOOD PRESSURE DEVICE FOR THE DETECTION OF ELEVATED BLOOD PRESSURE
    Socrates, T.
    Krisai, P.
    Meienberg, A.
    Mayr, M.
    Vischer, A. S.
    Burkard, T.
    JOURNAL OF HYPERTENSION, 2019, 37 : E43 - E43
  • [10] STATISTICAL CONSIDERATIONS IN AMBULATORY BLOOD-PRESSURE MONITORING
    PHILLIPS, RA
    THORNTON, J
    KRAKOFF, LR
    CLINICAL RESEARCH, 1987, 35 (03): : A358 - A358