A Review of the Effectiveness of Shielding Curtains for Improving Radiation Safety Management of Electromagnetic Radiation in Diagnostic X-ray Rooms

被引:0
|
作者
Kim, Jeong-Ho [1 ]
Kim, Gap-Jung [2 ]
Yoo, Se-Jong [3 ]
Ju, Myeong-Sik [2 ]
机构
[1] Sunlin Univ, Dept Radiol Sci, Pohang 37560, South Korea
[2] Songho Univ, Dept Radiol Sci, Hoengseong 25242, South Korea
[3] Konyang Univ, Dept Radiol Sci, Daejeon 35365, South Korea
关键词
electro-magnetic radiation shielding; electro-magnetic radiation; curtain; lead;
D O I
10.4283/JMAG.2023.28.4.438
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
During diagnostic radiography examinations, due to problems such as patient falls, the door between the examination room and the control room is often opened for quick action. Therefore, the purpose of this study is to evaluate the effectiveness of curtain-type shielding for worker radiation protection. Shielding efficiency, weight, cost, and user opinions were analyzed for leaded, leaded rubber, lead-free shielding sheet, and chainmail. The results showed that the shielding efficiency was 97.7 % for the steel door, 97.5 % for the lead sheet, 97.0 % for the lead rubber, 96.0 % for the lead-free sheet, and 91.3 % for the chain mail, and the weight was 7,399 g for the lead sheet, 8,482 g for the lead rubber, 1,148 g for the lead-free sheet, and 8,127 g for the chain mail. The cost was $46.9 for the lead sheet, $126 for the lead rubber, $270.5 for the lead-free sheet, and $147.8 for the chain mail. Based on this, it is believed that shielding curtains can be used to provide both worker and patient safety by considering the conditions of diagnostic radiography rooms in each medical institution.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 50 条
  • [31] X-ray spectroscopy applied to radiation shielding calculation in mammography
    Kuenzel, Roseli
    Levenhagen, Ronaldo Savarino
    Herdade, Silvio Bruni
    Terini, Ricardo Andrade
    Costa, Paulo Roberto
    MEDICAL PHYSICS, 2008, 35 (08) : 3539 - 3545
  • [32] SCATTERED RADIATION REACHING DOORS AND WINDOWS OF DIAGNOSTIC-X-RAY ROOMS
    LAW, J
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (710): : 179 - 180
  • [33] Scatter radiation levels in X-ray rooms during chest radiography
    Onu, Chiamaka Peace
    Nzotta, Chukwuemeka Christian
    APPLIED RADIATION AND ISOTOPES, 2024, 212
  • [34] Radiation protection in dental X-ray surgeries - still rooms for improvement
    Hart, G.
    Dugdale, M.
    BRITISH DENTAL JOURNAL, 2013, 214 (06) : 300 - 301
  • [35] STRAY RADIATION FROM DIAGNOSTIC X-RAY BEAMS
    KEANE, BE
    SPIEGLER, G
    BRITISH JOURNAL OF RADIOLOGY, 1951, 24 (280): : 198 - 203
  • [36] A Modified Radiation Kilovoltmeter for X-Ray Diagnostic Apparatuses
    Berdyakov G.I.
    Blinov N.N.
    Blinov, N. N. (otdel-22@mail.ru), 1600, Springer Science and Business Media, LLC (46): : 180 - 182
  • [37] RADIATION DOSES FROM DIAGNOSTIC X-RAY STUDIES
    HANDLOSER, JS
    LOVE, RA
    RADIOLOGY, 1951, 57 (02) : 252 - 254
  • [38] Effectiveness evaluation of self-produced micro- and nanosized tungsten materials for radiation shielding with diagnostic X-ray imaging system
    Hong, Ji Woo
    Kim, Dae Ho
    Kim, Seok Won
    Choi, Seong Hoon
    Lee, Ga-Eul
    Seo, Hyun-Kyu
    Kim, Sang-Hyun
    Lee, Youngjin
    OPTIK, 2018, 172 : 760 - 765
  • [39] Radiation safety of patients during x-ray examination
    Voronin K.V.
    Smerdova L.A.
    Biomedical Engineering, 1998, 32 (3) : 169 - 173
  • [40] Characterization of the radiation shielding properties of fired lead sample for X-ray shielding applications
    Umeh, Chibuike Dominic
    Agwu, Kenneth Kalu
    Okoye, Chukwuemeka Madubuko Ijeoma
    Ahia, Christian Chinedu
    Ikegbu, Godswill Ogbu
    PROGRESS IN NUCLEAR ENERGY, 2021, 137