X-ray spectroscopy applied to radiation shielding calculation in mammography

被引:4
|
作者
Kuenzel, Roseli
Levenhagen, Ronaldo Savarino [1 ]
Herdade, Silvio Bruni [2 ]
Terini, Ricardo Andrade [3 ]
Costa, Paulo Roberto [4 ]
机构
[1] Ctr Univ Franciscano, Area Ciencias Nat & Tecnol, BR-97010032 Santa Maria, RS, Brazil
[2] Univ Sao Paulo, Inst Fis, BR-05508900 Sao Paulo, Brazil
[3] Pontificia Univ Catolica Sao Paulo, Dept Fis, BR-01303050 Sao Paulo, Brazil
[4] Univ Sao Paulo, Inst Eletrotecn & Energia, Secao Tecn Desenvolvimento Tecnol Saude, BR-05508010 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
x-ray spectroscopy; scattered radiation; air kerma; shielding design; scatter fraction;
D O I
10.1118/1.2953566
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The protective shielding design of a mammography facility requires the knowledge of the scattered radiation by the patient and image receptor components. The shape and intensity of secondary x-ray beams depend on the kVp applied to the x-ray tube, target/filter combination, primary x-ray field size, and scattering angle. Currently, shielding calculations for mammography facilities are performed based on scatter fraction data for Mo/Mo target/filter, even though modern mammography equipment is designed with different anode/filter combinations. In this work we present scatter fraction data evaluated based on the x-ray spectra produced by a Mo/Mo, Mo/Rh and W/Rh target/filter, for 25, 30 and 35 kV tube voltages and scattering angles between 30 and 165 degrees. Three mammography phantoms were irradiated and the scattered radiation was measured with a CdZnTe detector. The primary x-ray spectra were computed with a semiempirical model based on the air kerma and HVL measured with an ionization chamber. The results point out that the scatter fraction values are higher for W/Rh than for Mo/Mo and Mo/Rh, although the primary and scattered air kerma are lower for W/Rh than for Mo/Mo and Mo/Rh target/filter combinations. The scatter fractions computed in this work were applied in a shielding design calculation in order to evaluate shielding requirements for each of these target/filter combinations. Besides, shielding requirements have been evaluated converting the scattered air kerma from mGy/week to mSv/week adopting initially a conversion coefficient from air kerma to effective dose as 1 Sv/Gy and then a mean conversion coefficient specific for the x-ray beam considered. Results show that the thickest barrier should be provided for Mo/Mo target/filter combination. They also point out that the use of the conversion coefficient from air kerma to effective dose as 1 Sv/Gy is conservatively high in the mammography energy range and overestimate the barrier thickness. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3539 / 3545
页数:7
相关论文
共 50 条
  • [1] X-Ray Scattering and Spectroscopy Applied to Mammography: An Initial Study
    Ganezer, K.
    Krmar, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Reduction of scattered radiation dose by X-ray shielding during mammography
    Koo, Bon-Yeoul
    Lee, Kwang-Sung
    RADIATION PHYSICS AND CHEMISTRY, 2020, 177
  • [3] Shielding calculation for high energy radiation x-ray by software program
    Rahimi, Seyed Ali
    HIGH ENERGY PHYSICS AND APPLICATIONS, 2008, 1006 : 190 - 195
  • [4] X-RAY MAMMOGRAPHY WITH SYNCHROTRON RADIATION
    BURATTINI, E
    GAMBACCINI, M
    MARZIANI, M
    RIMONDI, O
    INDOVINA, PL
    POCEK, M
    SIMONETTI, G
    BENASSI, M
    TIRELLI, C
    PASSARIELLO, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 638 - 640
  • [5] The Radiation Shielding Design of X-Ray Velocimeter
    Bo, Yang
    2016 3RD INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2016, : 650 - 654
  • [6] APPLIED X-RAY PHOTOELECTRON SPECTROSCOPY
    NOVAKOV, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1972, : 31 - &
  • [7] A new shielding calculation method for X-ray computed tomography regarding scattered radiation
    Watanabe H.
    Noto K.
    Shohji T.
    Ogawa Y.
    Fujibuchi T.
    Yamaguchi I.
    Hiraki H.
    Kida T.
    Sasanuma K.
    Katsunuma Y.
    Nakano T.
    Horitsugi G.
    Hosono M.
    Radiological Physics and Technology, 2017, 10 (2) : 213 - 226
  • [8] Synchrotron radiation: New trend in X-ray mammography
    Burattini, E
    ACTA PHYSICA POLONICA A, 1997, 91 (04) : 707 - 713
  • [9] Radiation exposure in X-ray mammography -: A review.
    Säbel, M
    Aichinger, U
    Schulz-Wendtland, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (02): : 79 - 91
  • [10] X-ray photoelectron spectroscopy, structural, and radiation shielding properties for transparent borosilicate glasses
    Mhareb, M. H. A.
    Mekki, Abdelkrim
    Alwabsi, Amnah
    Almaimouni, Ashwag
    Thabit, Hammam Abdurabu
    Alshwaira, Nouf
    Alsaleh, Istbrq Ahmad
    Al-Dhahi, Fatimah Awn
    OPTICAL MATERIALS, 2024, 152