Conversion of single-energy CT to parametric maps of dual-energy CT using convolutional neural network

被引:2
|
作者
Kim, Sangwook [1 ,2 ]
Lee, Jimin [1 ,3 ]
Kim, Jungye [4 ]
Kim, Bitbyeol [5 ]
Choi, Chang Heon [5 ,6 ,7 ,8 ]
Jung, Seongmoon [1 ,5 ,7 ,8 ,9 ]
机构
[1] Ulsan Natl Inst Sci & Technol, Dept Nucl Engn, Ulsan 44919, South Korea
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
[3] Ulsan Natl Inst Sci & Technol, Grad Sch Artificial Intelligence, Ulsan 44919, South Korea
[4] Korea Univ, Dept Biomed Engn, Seoul 02841, South Korea
[5] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 03080, South Korea
[6] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul 03080, South Korea
[7] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
[8] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul 03080, South Korea
[9] Korea Res Inst Stand & Sci, Div Biomed Metrol, Ionizing Radiat Grp, Daejeon 34114, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2024年 / 97卷 / 1158期
基金
新加坡国家研究基金会;
关键词
dual-energy computed tomography; convolutional neural network; deep learning; virtual monoenergetic imaging; effective atomic number; relative electron density;
D O I
10.1093/bjr/tqae076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives We propose a deep learning (DL) multitask learning framework using convolutional neural network for a direct conversion of single-energy CT (SECT) to 3 different parametric maps of dual-energy CT (DECT): virtual-monochromatic image (VMI), effective atomic number (EAN), and relative electron density (RED).Methods We propose VMI-Net for conversion of SECT to 70, 120, and 200 keV VMIs. In addition, EAN-Net and RED-Net were also developed to convert SECT to EAN and RED. We trained and validated our model using 67 patients collected between 2019 and 2020. Single-layer CT images with 120 kVp acquired by the DECT (IQon spectral CT; Philips Healthcare, Amsterdam, Netherlands) were used as input, while the VMIs, EAN, and RED acquired by the same device were used as target. The performance of the DL framework was evaluated by absolute difference (AD) and relative difference (RD).Results The VMI-Net converted 120 kVp SECT to the VMIs with AD of 9.02 Hounsfield Unit, and RD of 0.41% compared to the ground truth VMIs. The ADs of the converted EAN and RED were 0.29 and 0.96, respectively, while the RDs were 1.99% and 0.50% for the converted EAN and RED, respectively.Conclusions SECT images were directly converted to the 3 parametric maps of DECT (ie, VMIs, EAN, and RED). By using this model, one can generate the parametric information from SECT images without DECT device. Our model can help investigate the parametric information from SECT retrospectively.Advances in knowledge DL framework enables converting SECT to various high-quality parametric maps of DECT.
引用
收藏
页码:1180 / 1190
页数:11
相关论文
共 50 条
  • [21] Dual-contrast decomposition of dual-energy CT using convolutional neural networks
    Shapira, Nadav
    Cao, Wenchao
    Liu, Leening P.
    Leiner, Tim
    Smits, Maarten L. J.
    Noel, Peter B.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [22] Real-time diagnosis of intracerebral hemorrhage by generating dual-energy CT from single-energy CT
    Jiang, Caiwen
    Wang, Tianyu
    Pan, Yongsheng
    Ding, Zhongxiang
    Shen, Dinggang
    MEDICAL IMAGE ANALYSIS, 2024, 95
  • [23] Stopping Power Map Estimation from Dual-Energy CT Using Deep Convolutional Neural Network
    Wang, Tonghe
    Lei, Yang
    Harms, Joseph
    Liu, Yingzi
    Ghavidel, Beth
    Lin, Liyong
    Beitler, Jonathan J.
    Curran, Walter J.
    Liu, Tian
    Zhou, Jun
    Yang, Xiaofeng
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [24] The Effect of Beam Overlapping in Dual-Energy Volume CT Scans and Single-Energy Helical Scans
    Correa, N.
    Barreto, I.
    Arreola, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E648 - E648
  • [25] Accuracy of liver metastasis detection and characterization: Dual-energy CT versus single-energy CT with deep learning reconstruction
    Jensen, Corey T.
    Wong, Vincenzo K.
    Wagner-Bartak, Nicolaus A.
    Liu, Xinming
    Sobha, Renjith Padmanabhan Nair
    Sun, Jia
    Likhari, Gauruv S.
    Gupta, Shiva
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [26] Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
    Lundin, Margareta
    Liden, Mats
    Magnuson, Anders
    Mohammed, Ahmed Abdulilah
    Geijer, Hakan
    Andersson, Torbjorn
    Persson, Anders
    ACTA RADIOLOGICA, 2012, 53 (06) : 689 - 694
  • [27] Deep-learned generation of renal dual-energy CT from a single-energy scan
    Sheikhi, M.
    Sina, S.
    Karimipourfard, M.
    CLINICAL RADIOLOGY, 2024, 79 (01) : e17 - e25
  • [28] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [29] Attention Augmented Deep Learning-Based Dual-Energy CT Imaging Via Single-Energy CT Data
    Zhang, W.
    Lv, T.
    Chen, Y.
    Sun, B.
    Zhao, W.
    MEDICAL PHYSICS, 2022, 49 (06) : E181 - E181
  • [30] Myocardial late enhancement using dual-source CT: intraindividual comparison of single-energy shuttle and dual-energy acquisition
    Takanori Kokawa
    Kakuya Kitagawa
    Satoshi Nakamura
    Masafumi Takafuji
    Takashi Oya
    Hajime Sakuma
    Insights into Imaging, 16 (1)