Conversion of single-energy CT to parametric maps of dual-energy CT using convolutional neural network

被引:2
|
作者
Kim, Sangwook [1 ,2 ]
Lee, Jimin [1 ,3 ]
Kim, Jungye [4 ]
Kim, Bitbyeol [5 ]
Choi, Chang Heon [5 ,6 ,7 ,8 ]
Jung, Seongmoon [1 ,5 ,7 ,8 ,9 ]
机构
[1] Ulsan Natl Inst Sci & Technol, Dept Nucl Engn, Ulsan 44919, South Korea
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
[3] Ulsan Natl Inst Sci & Technol, Grad Sch Artificial Intelligence, Ulsan 44919, South Korea
[4] Korea Univ, Dept Biomed Engn, Seoul 02841, South Korea
[5] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 03080, South Korea
[6] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul 03080, South Korea
[7] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
[8] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul 03080, South Korea
[9] Korea Res Inst Stand & Sci, Div Biomed Metrol, Ionizing Radiat Grp, Daejeon 34114, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2024年 / 97卷 / 1158期
基金
新加坡国家研究基金会;
关键词
dual-energy computed tomography; convolutional neural network; deep learning; virtual monoenergetic imaging; effective atomic number; relative electron density;
D O I
10.1093/bjr/tqae076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives We propose a deep learning (DL) multitask learning framework using convolutional neural network for a direct conversion of single-energy CT (SECT) to 3 different parametric maps of dual-energy CT (DECT): virtual-monochromatic image (VMI), effective atomic number (EAN), and relative electron density (RED).Methods We propose VMI-Net for conversion of SECT to 70, 120, and 200 keV VMIs. In addition, EAN-Net and RED-Net were also developed to convert SECT to EAN and RED. We trained and validated our model using 67 patients collected between 2019 and 2020. Single-layer CT images with 120 kVp acquired by the DECT (IQon spectral CT; Philips Healthcare, Amsterdam, Netherlands) were used as input, while the VMIs, EAN, and RED acquired by the same device were used as target. The performance of the DL framework was evaluated by absolute difference (AD) and relative difference (RD).Results The VMI-Net converted 120 kVp SECT to the VMIs with AD of 9.02 Hounsfield Unit, and RD of 0.41% compared to the ground truth VMIs. The ADs of the converted EAN and RED were 0.29 and 0.96, respectively, while the RDs were 1.99% and 0.50% for the converted EAN and RED, respectively.Conclusions SECT images were directly converted to the 3 parametric maps of DECT (ie, VMIs, EAN, and RED). By using this model, one can generate the parametric information from SECT images without DECT device. Our model can help investigate the parametric information from SECT retrospectively.Advances in knowledge DL framework enables converting SECT to various high-quality parametric maps of DECT.
引用
收藏
页码:1180 / 1190
页数:11
相关论文
共 50 条
  • [1] Estimating dual-energy CT imaging from single-energy CT data with material decomposition convolutional neural network ?
    Lyu, Tianling
    Zhao, Wei
    Zhu, Yinsu
    Wu, Zhan
    Zhang, Yikun
    Chen, Yang
    Luo, Limin
    Li, Shuo
    Xing, Lei
    MEDICAL IMAGE ANALYSIS, 2021, 70
  • [2] Pseudo dual-energy CT-derived iodine mapping using single-energy CT data based on a convolution neural network
    Yuasa, Yuki
    Shiinoki, Takehiro
    Fujimoto, Koya
    Tanaka, Hidekazu
    BJR OPEN, 2023, 5 (01):
  • [3] Generation of Brain Dual-Energy CT from Single-Energy CT Using Deep Learning
    Liu, Chi-Kuang
    Liu, Chih-Chieh
    Yang, Cheng-Hsun
    Huang, Hsuan-Ming
    JOURNAL OF DIGITAL IMAGING, 2021, 34 (01) : 149 - 161
  • [4] A deep learning approach for dual-energy CT imaging using a single-energy CT data
    Zhao, Wei
    Lv, Tianling
    Gao, Peng
    Shen, Liyue
    Dai, Xianjin
    Cheng, Kai
    Jia, Mengyu
    Chen, Yang
    Xing, Lei
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [5] Generation of Brain Dual-Energy CT from Single-Energy CT Using Deep Learning
    Chi-Kuang Liu
    Chih-Chieh Liu
    Cheng-Hsun Yang
    Hsuan-Ming Huang
    Journal of Digital Imaging, 2021, 34 : 149 - 161
  • [6] Synthetic dual-energy CT reconstruction from single-energy CT Using artificial intelligence
    Jeong, Jiwoong
    Wentland, Andrew
    Mastrodicasa, Domenico
    Fananapazir, Ghaneh
    Wang, Adam
    Banerjee, Imon
    Patel, Bhavik N.
    ABDOMINAL RADIOLOGY, 2023, 48 (11) : 3537 - 3549
  • [7] Synthetic dual-energy CT reconstruction from single-energy CT Using artificial intelligence
    Jiwoong Jeong
    Andrew Wentland
    Domenico Mastrodicasa
    Ghaneh Fananapazir
    Adam Wang
    Imon Banerjee
    Bhavik N. Patel
    Abdominal Radiology, 2023, 48 : 3537 - 3549
  • [8] INFLUENCE OF CALIBRATION MATERIALS IN SINGLE-ENERGY AND DUAL-ENERGY QUANTITATIVE CT
    STEENBEEK, JCM
    VANKUIJK, C
    GRASHUIS, JL
    RADIOLOGY, 1992, 183 (03) : 849 - 855
  • [9] Robustness of CT radiomics features: consistency within and between single-energy CT and dual-energy CT
    Chen, Yong
    Zhong, Jingyu
    Wang, Lan
    Shi, Xiaomeng
    Lu, Wei
    Li, Jianying
    Feng, Jianxing
    Xia, Yihan
    Chang, Rui
    Fan, Jing
    Chen, Liwei
    Zhu, Ying
    Yan, Fuhua
    Yao, Weiwu
    Zhang, Huan
    EUROPEAN RADIOLOGY, 2022, 32 (08) : 5480 - 5490
  • [10] Robustness of CT radiomics features: consistency within and between single-energy CT and dual-energy CT
    Yong Chen
    Jingyu Zhong
    Lan Wang
    Xiaomeng Shi
    Wei Lu
    Jianying Li
    Jianxing Feng
    Yihan Xia
    Rui Chang
    Jing Fan
    Liwei Chen
    Ying Zhu
    Fuhua Yan
    Weiwu Yao
    Huan Zhang
    European Radiology, 2022, 32 : 5480 - 5490