Effect of blockage on critical ventilation velocity in longitudinally ventilated tunnel fires

被引:26
|
作者
Meng, Na [1 ]
Hu, Xiangming [1 ]
Tian, Mengya [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Safety & Environm Engn, Qingdao 266590, Shandong, Peoples R China
关键词
Tunnel fire; Critical ventilation velocity; Blockage-fire distance; Blockage ratio; Blockage orientation; Smoke control; SMOKE FLOW; TEMPERATURE; LENGTH; RATIO; ROAD; UPSTREAM; BEHAVIOR; RAILWAY; SAFETY; MODEL;
D O I
10.1016/j.tust.2020.103580
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Effect of blockage on critical ventilation velocity in longitudinally ventilated tunnel fires was investigated based on small-scale experiments and numerical simulations. Blockages were located right upstream of the fire or 3.5 m upstream of the fire. At each location, blockages have five blockage ratios and two orientations. Experimental data shows that the factors as blockage ratio, blockage-fire distance and blockage orientation could have coupling effect on the critical ventilation velocity. For blockage right upstream of the fire, the critical ventilation velocity decreases with the increasing blockage ratio when blockages are horizontally positioned, while there is first decrease and then increase in the critical ventilation velocity for blockage vertically positioned. A correlation was proposed to predict the critical ventilation velocity for blockages right upstream of the fire and horizontally positioned. For blockage 3.5 m upstream of the fire, the change in the critical ventilation velocity is very slight with the increasing blockage ratio for blockages vertically positioned, however, when blockages are horizontally positioned, there is an increase in the critical ventilation velocity for large blockage ratios. The change in the critical ventilation velocity with increasing blockage ratio is more obvious for blockages right upstream of the fire than that for blockages 3.5 m upstream of the fire. Numerical simulations were also conducted in the tunnel without fire. The altered tunnel flow field due to the obstruction of blockage was observed and its effect on the critical ventilation velocity was addressed. Comparison of the critical ventilation velocity between the experimental data and the results from previous studies showed that the critical ventilation velocity changed differently with the existence of blockage. The reason for this difference might be that the relative position between the blockage and the fire, and the fuel type could have coupling effect on the critical ventilation velocity.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] FIRE SIZING IN LONGITUDINALLY VENTILATED TUNNEL
    Zhang, Qihui
    Eandi, Seamine
    Cappello, Deniele
    Astore, Giuseppe
    Grasso, Piergiorgio
    ADVANCES IN UNDERGROUND SPACE DEVELOPMENT, 2013, : 208 - 216
  • [42] Experimental Study on the Influence of Different Transverse Fire Locations on the Critical Longitudinal Ventilation Velocity in Tunnel Fires
    Zhong, Wei
    Li, Zhaozhou
    Wang, Tao
    Liang, Tianshui
    Liu, Zhen
    FIRE TECHNOLOGY, 2015, 51 (05) : 1217 - 1230
  • [43] Experimental Study on the Influence of Different Transverse Fire Locations on the Critical Longitudinal Ventilation Velocity in Tunnel Fires
    Wei Zhong
    Zhaozhou Li
    Tao Wang
    Tianshui Liang
    Zhen Liu
    Fire Technology, 2015, 51 : 1217 - 1230
  • [44] Evaluating the impact of tunnel slope on critical velocity and confinement velocity in metro tunnel carriage fires
    Su, Zhihe
    Li, Yanfeng
    Zhong, Hua
    Li, Junmei
    Li, Boyu
    Kang, Siyan
    Huang, Youbo
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 154
  • [45] Experimental study on flame merging behaviors and smoke backlayering length of two fires in a longitudinally ventilated tunnel
    Meng, Na
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 137
  • [46] Effect of tunnel slope on the critical velocity of densimetric plumes and fire plumes in ventilated tunnels
    Jiang, Lei
    Xiao, Ming
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 123
  • [47] Experimental study and machine learning on the maximum temperature beneath tunnel ceiling induced by adjacent tandem fires in longitudinally ventilated tunnel
    Liu, Wei
    Deng, Lei
    Li, Haoran
    Li, Xuechun
    Shi, Congling
    Meng, Na
    Tang, Fei
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 187
  • [48] Critical velocity and backlayering distance in tunnel fires with longitudinal ventilation taking thermal properties of wall materials into consideration
    Tanaka, Futoshi
    Takezawa, Kohei
    Hashimoto, Yuji
    Moinuddin, Khalid A. M.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 75 : 36 - 42
  • [49] Theoretical model of critical wind velocity in horizontal tunnel fires
    Xu, Zhisheng
    Zhao, Hongli
    Li, Hong
    Jiang, Xuepeng
    Li, Dong
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2013, 44 (03): : 1138 - 1143
  • [50] Prediction of backlayering length and critical velocity in metro tunnel fires
    Weng, Miao-cheng
    Lu, Xin-ling
    Liu, Fang
    Shi, Xiang-peng
    Yu, Long-xing
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2015, 47 : 64 - 72