Effect of blockage on critical ventilation velocity in longitudinally ventilated tunnel fires

被引:26
|
作者
Meng, Na [1 ]
Hu, Xiangming [1 ]
Tian, Mengya [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Safety & Environm Engn, Qingdao 266590, Shandong, Peoples R China
关键词
Tunnel fire; Critical ventilation velocity; Blockage-fire distance; Blockage ratio; Blockage orientation; Smoke control; SMOKE FLOW; TEMPERATURE; LENGTH; RATIO; ROAD; UPSTREAM; BEHAVIOR; RAILWAY; SAFETY; MODEL;
D O I
10.1016/j.tust.2020.103580
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Effect of blockage on critical ventilation velocity in longitudinally ventilated tunnel fires was investigated based on small-scale experiments and numerical simulations. Blockages were located right upstream of the fire or 3.5 m upstream of the fire. At each location, blockages have five blockage ratios and two orientations. Experimental data shows that the factors as blockage ratio, blockage-fire distance and blockage orientation could have coupling effect on the critical ventilation velocity. For blockage right upstream of the fire, the critical ventilation velocity decreases with the increasing blockage ratio when blockages are horizontally positioned, while there is first decrease and then increase in the critical ventilation velocity for blockage vertically positioned. A correlation was proposed to predict the critical ventilation velocity for blockages right upstream of the fire and horizontally positioned. For blockage 3.5 m upstream of the fire, the change in the critical ventilation velocity is very slight with the increasing blockage ratio for blockages vertically positioned, however, when blockages are horizontally positioned, there is an increase in the critical ventilation velocity for large blockage ratios. The change in the critical ventilation velocity with increasing blockage ratio is more obvious for blockages right upstream of the fire than that for blockages 3.5 m upstream of the fire. Numerical simulations were also conducted in the tunnel without fire. The altered tunnel flow field due to the obstruction of blockage was observed and its effect on the critical ventilation velocity was addressed. Comparison of the critical ventilation velocity between the experimental data and the results from previous studies showed that the critical ventilation velocity changed differently with the existence of blockage. The reason for this difference might be that the relative position between the blockage and the fire, and the fuel type could have coupling effect on the critical ventilation velocity.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Critical review of the common methods to determine the buoyancy-chimney effects in longitudinally-ventilated traffic tunnel fires
    Vukoslavcevic, Petar V.
    Sekularac, Milan B.
    ADVANCES IN MECHANICAL ENGINEERING, 2022, 14 (05)
  • [32] Experimental study on effect of longitudinal ventilation velocity on burning rate in tunnel fires
    Yang, SS
    Rho, JS
    Ryou, HS
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 913 - 920
  • [33] DISTRIBUTION OF SMOKE BACKFLOW TEMPERATURE UNDER CEILING IN LONGITUDINALLY-VENTILATED TUNNEL FIRES
    Li, Yingzhen
    Lei, Bo
    Xu, Zhihao
    Deng, Zhihui
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 321 - 328
  • [34] Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity
    Wu, Y
    Bakar, MZA
    Jagger, S
    Bettis, R
    Allen, J
    10TH INTERNATIONAL SYMPOSIUM ON AERODYNAMICS AND VENTILATION OF VEHICLE TUNNELS: PRINCIPLES, ANALYSIS AND DESIGN, 2000, (43): : 639 - 657
  • [35] Effects of False-Ceiling on Critical Ventilation Velocity and Maximum Gas Temperature in Tunnel Fires
    Savalanpour, H.
    Farhanieh, B.
    Afshin, H.
    JOURNAL OF APPLIED FLUID MECHANICS, 2021, 14 (02) : 473 - 483
  • [36] Tunnel fires: Experiments on critical velocity and burning rate in pool fire during longitudinal ventilation
    Roh, Jae Seong
    Yang, Seung Shin
    Ryou, Hong Sun
    JOURNAL OF FIRE SCIENCES, 2007, 25 (02) : 161 - 176
  • [37] Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity
    Wu, Y
    Bakar, MZA
    FIRE SAFETY JOURNAL, 2000, 35 (04) : 363 - 390
  • [38] Ceiling temperature rise and critical ventilation velocity under the influence of burner dimensions in tunnel fires
    Chen, Yanqiu
    Feng, Qianhang
    Zhao, Yi
    Wang, Peng
    Zhang, Yuchun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 150
  • [39] Experimental Study of Sub-critical Velocity in Longitudinally Ventilated Tunnels
    Gao, Dongli
    Chen, Xingchao
    Yang, Xinyu
    Tong, Y. O.
    Lin, Peng
    FIRE TECHNOLOGY, 2022, 58 (01) : 571 - 590
  • [40] Experimental Study of Sub-critical Velocity in Longitudinally Ventilated Tunnels
    Dongli Gao
    Xingchao Chen
    Xinyu Yang
    Y. O. Tong
    Peng Lin
    Fire Technology, 2022, 58 : 571 - 590